Bare Wire Length
Conductor Material
Sectional Area
Value
10~12mm
2
20~25mm
10mm around
08
07
Figure
4.2-3
Installation instruction of SUNCLIX please refer to Figure 4.2-2.
Installation instruction of MC4 please refer to Figure 4.2-3.
Negative
plug
Positive
plug
Figure
4.2-2
Figure
4.3-1
A
B
C
Special tools are used to stitching
Inverter
side
4.3 Battery Connection
Before connecting to battery, please install a separate DC breaker (60A for Replus 3648ME and 120A for
) between
inverter and battery. This will ensure the inverter can be securely disconnected during maintenance.
●
Be aware of electric shock and chemical hazards!
●
It is a normal phenomenon that electric arc occurs when connecting battery to the inverter without use a DC breaker.
●
It's very important for system safety and efficient operation to use appropriate cable for battery connection. To reduce risk of
injury, please use the proper recommended cable size. Refer to Figure 4.3-1.
Replus 5048ME
●
if
t
to
be
for
●
Suggestion: Batteries
must be installed with a distance to each other, details please refer to battery manufacture's user manual.
●
As
for the number of cells used, it will be decided by customer's choice, the choice must
comply with the followed requirement:
the rated voltage is 48V.
Please follow below steps to implement battery connection:
(
1
)
Check the nominal voltage of batteries. The nominal output voltage should meet ReneSola product Spec.
(
2
)
Disconnect DC breaker between inverter and battery.
(
3
)
Disconnect screw cap from insulator.
(
4
)
Disconnect waterproof ring from insulator.
(
5
)
Put the cable through the components in this order: screw cap, waterproof ring, insulator, battery cover and battery terminal.
Refer to Figure 4.3-2.
(
6
)
Compress the terminal head by professional tool and screw down screw cap slight. Refer to Figure 4.3-3, Figure 4.3-4.
(
7
)
Put battery terminals into the corresponding holes and fasten them by screwdriver and spanner
(
recommended torsion:50~70Kg-
f.cm), then fasten battery cover with pan head screws in accessory bag. Refer to Figure 4.3-5, Figure 4.3-6, Figure 4.3-7.
(
8
)
Screw down screw cap again.
Suggestion:
he battery is
installed indoor,
details please refer to battery manufacture's user manual.
Positive
plug
N
egative
plug
Inverter
side
7mm
7mm
2
2
.
5
~
4mm
2
2
.
5
~
4mm
Figure
4.3-3
Crimp
Cable
Figure
4.3-2
Waterproof
ring
Battery
cover
Battery
terminal
Screw
cap
Insulator
SUNCLIX
Series
MC4
Series
Figure
4.2-1
There are two types of DC plugs, SUNCLIX and MC4 series. Please refer to Figure 4.2-1.
●
permanently damage the inverter.
·
●
Check the short-circuit current of the PV string. The total short-circuit current must not exceed the inverter’s maximum PV current.
·
●
PV array should not be connected to the grounding conductor.
·
●
Must be use DC plugs in accessory bag.
·
●
The minimum insulation resistance to ground of
the
PV pannels
must
exceed 19.33k
Ω
, there is a risk of shock hazard if the
requirement of
minimum resistance is not met.
Before connecting the PV panels, ensure the plug connectors have the correct polarity. Incorrect polarity could
4.2 PV Connection
●
Reversed
polarity
will
damage
the
inverter
!