IMPORTANT
If you have already used IP address 39.40.41.44 in a local area network, you cannot use this procedure. Carry out "(1)
Using the emulator debugger M3T-PDxxF" (P.31).
IMPORTANT
If the LAN interface is used as the PC7501 communication interface, it is necessary to acquire an IP address of the
PC7501. For details, contact your network administrator.
IMPORTANT
To register network information, shut power to the PC7501 OFF and restart. The registered information is activated by
restarting the PC7501.
IMPORTANT
The PC7501 cannot communicate with more than one host machine at a time. It communicates with the first host
machine to which the PC7501 is connected.
IMPORTANT
The initial values of network information for the PC7501 are as follows.
IP address: 39.40.41.44
Subnet mask: 255.255.255.255
Port number: 7500
Gateway: 255.255.255.255 (not in use)
IMPORTANT
SETIP.EXE detects the PC7501 at IP address 39.40.41.44 and port number 7500. If the IP address is changed, you
cannot register network information using the SETIP.EXE.
IMPORTANT
SETIP.EXE does not detect a PC7501 on another network.
IMPORTANT
When SETIP.EXE detects the PC7501, it temporarily rewrites the network table of the host machine.
Incorporating the Emulator PC7501 in a Different Network
In incorporating the emulator PC7501 in a network that does not include the host machine, you need to register the IP
address of the gateway from the network in which the emulator PC7501 is incorporated to the network in which the host
machine is incorporated. You register the IP address of the gateway by means of either step 1 described in "(1) Using
the emulator debugger M3T-PDxxF" (P.31) or step 5 described in "(2) Using the SETIP.EXE" (P.32).
After you finished registering the network information by use of the host machine in which the emulator debugger
M3T-PDxxF is installed, incorporate the emulator PC7501 in the network intended. In case of the following network
construction, register 192.168.2.254 as the IP address of the gateway.
Figure 4.6 Network configuration
+
*
>9@;<:
/50-/34-/-021
/50-/34-0-021
/50-/34-0-/
A?@B9= 876 /50-/34-0-.
/50-/34-/-/
A?@B9= 876 /50-/34-/-.
Network ID: 192.168.1.0
Gateway
Network ID: 192.168.2.0
192.168.1.1
192.168.2.1
192.168.1.254 192.168.2.254
Содержание PC7501
Страница 14: ...PC7501 User s Manual 1 Precautions for Safety R20UT0207EJ0500 Rev 5 00 Page 14 of 50 Nov 01 2010 MEMO...
Страница 38: ...PC7501 User s Manual 4 Setup R20UT0207EJ0500 Rev 5 00 Page 38 of 50 Nov 01 2010 MEMO...
Страница 50: ...PC7501 User s Manual R20UT0207EJ0500 Previous Number REJ10J0078 0400...