IMPORTANT

Note on MCU Functions That Cannot Be Used with This Emulator:

• The following MCU features cannot be used with this emulator.

(1) Debugging cannot be done with this emulator in the memory expansion mode or micropro-

cessor mode.
This emulator is specifically designed for use in the single-chip mode. For this reason,
debugging is not possible in the memory expansion mode or microprocessor mode.

• When using this emulator, normally set the processor mode bit in the processor mode register

to the "single-chip mode".

• When using this emulator, set the CNVSS and BYTE pins to "L" level.

(2) Oscillation circuits that use a resonator cannot be used.

Because a control gate array is situated between the evaluation MCU and the target system,
oscillation circuits that connect a resonator between the X

IN

 and X

OUT

 pins will not oscillate.

The same applies to the sub-clock oscillation circuit (X

CIN

, X

COUT

): oscillation circuits with a

resonator cannot be used. See "3.5 Selecting Clock Supply" (page 29).

(3) Watchdog timers cannot be used.

MCU watchdog timers can only be used during program execution (free running). Disable
watchdog timers in all other program operations (break, dump, forced stop, etc.). However,
under the condition below, it is not possible to use the program execution.

• When setting the watchdog timer selection bit (CM06) of the system clock control register

0 to "1".

Also, if the target system has a watchdog timer in its reset circuit, disable it, too, when using
the emulator.

(4) Single step interrupts (debug interrupt) cannot be used.

Single step interrupts cannot be used. The vector address of a single step interrupt is normally
indicated in the emulator work area, and the vector address value cannot be changed.

(5) The BRK2 interrupt (debug interrupt) cannot be used.

The BRK2 interrupt cannot be used. The vector address of the BRK2 interrupt is normally
indicated in the emulator work area, and the vector address value cannot be changed.

(6) Software reset function cannot be used.

Do not use the software reset function.

(7) A-D input group select function is unusable.

The A-D input group select function (M16C/80T Group-only function) cannot be used.

(8) MCUs with more than 10 KB of internal RAM cannot be debugged.

Because this product incorporates an MCU of a 10KB internal RAM version, MCUs whose
internal RAM size exceeds 10 KB cannot be debugged. The reserved internal area (002C00

16

through 007FFF

16

) cannot be used either.

(9) Flash memory and EPROM modes are not emulated.

This emulator does not emulate the flash memory and EPROM modes. Also, the emulator
does not emulate the CPU rewrite function in the flash memory mode.

Содержание M30800T-CPE

Страница 1: ...M30800T CPE Compact Emulator for M16C 80 Series User s Manual Rev 1 00 November 16 2003 REJ10J0271 0100Z...

Страница 2: ...on the applicability of the information and products Renesas Technology Corporation and Renesas Solutions Corporation assume no responsibility for any damage liability or other loss resulting from the...

Страница 3: ...nual Emulator debugger M3T PD308M C compiler M3T NC308WA entry version Integrated development environment TM If there is any question or doubt about this product contact your local distributor To use...

Страница 4: ...personal computer used to control the emulator Emulator debugger This means a software tool M3T PD308M to control the emulator from the host machine through an communications interface Evaluation MCU...

Страница 5: ...Emulator System 25 2 Turning On the Power 25 3 LED Display When the Emulator Starts Up Normally 26 2 7 Starting Up Emulator Debugger M3T PD308M 27 2 8 Setting the Operating Environment of Emulator Deb...

Страница 6: ...gger M3T PD308M Starts Up 42 5 2 Troubleshooting When Using Emulator Debugger M3T PD308M 43 5 3 When the Operation of the Emulator is Abnormal 44 1 Self check Procedure in the Self check Mode 44 2 If...

Страница 7: ...to Be Taken for Modifying This Product 9 Cautions to Be Taken for This Product 9 Note on Malfunctions in the System 9 Notes on Differences between the Actual MCU and Emulator 10 Note on MCU Functions...

Страница 8: ...ngs The following pages describe the symbols WARNING CAUTION and IMPORTANT In addition to the three above the following are also used as appropriate means WARNING or CAUTION Example CAUTION AGAINST AN...

Страница 9: ...d modifying the product will void your warranty Cautions to Be Taken for This Product Use caution when handling the main unit Be careful not to apply a mechanical shock Do not touch the connector pins...

Страница 10: ...faults to the reset vector value FC000016 initialized by the emulator 4 Internal memory RAM and ROM capacity etc Because the internal memories RAM and ROM are emulated by the emulation memory the capa...

Страница 11: ...ndition below it is not possible to use the program execution When setting the watchdog timer selection bit CM06 of the system clock control register 0 to 1 Also if the target system has a watchdog ti...

Страница 12: ...ytes If there isn t enough user stack area using other areas not designed for use as stacks SFR area RAM area that stores data or ROM area can damage the user program or destabilize emulator control T...

Страница 13: ...e program is stopped with a loop program to a specific address Therefore if a DMA request is generated by a timer or other source while the program is stopped DMA transfer is executed However make not...

Страница 14: ...tem so that the target system is powered separately This emulator consumes max 500 mA of electric current from the target system The voltage of the target system should be within the range of 4 5 to 5...

Страница 15: ...15 52 1 2 Declaration Concerning EMC Directive...

Страница 16: ...16 52 MEMO...

Страница 17: ...onnecting the Emulator System 23 1 Connecting the Serial Interface Cable 23 2 Connecting the Power Cable 23 2 5 Connecting Target System as occasion demands 24 2 6 Turning On the Power 25 1 Checking t...

Страница 18: ...separately The power cable is included with this product With some AC adapter the power voltage may be changed significantly by the load The switching power supply AC adapter or stabilized power suppl...

Страница 19: ...et MCU Power is not supplied to the target MCU BCLK is output from the target MCU BCLK is not output from the target MCU Target MCU is being reset Target MCU is not being reset User program is being e...

Страница 20: ...ot the emulator debugger M3T PD308M Otherwise the display of emulator debugger and the actual value in the emulator may not match When the emulator debugger does not start up normally even after reboo...

Страница 21: ...emulator when necessary Recheck the connection and turn on the emulator When the target system is connected turn on the target system too Turn them on as simultaneously as possible Check POWER and SAF...

Страница 22: ...tch according to the usage of P87 XCIN pin Table 2 5 Setting P87 XCIN select switch 1 P87 XCIN select switch SW1 2 MCU power supply select jumper JP1 3 MCU power voltage select jumper JP2 CAUTION Note...

Страница 23: ...ator Figures 2 6 and 2 7 show the specifications of the power connector J1 and the applicable plug respectively Figure 2 6 Specification of power connector Figure 2 7 Specification of applicable plug...

Страница 24: ...shut OFF power of the emulator and the target system when connecting and disconnecting the target system Figure 2 9 Connecting target system M30800T PTC Position of No 1 pin The pin No and O are marke...

Страница 25: ...le CAUTION Notes on Power Supply As this emulator cannot supply power to the target system provide the target system with a separate power supply from that of the emulator This emulator consumes max 5...

Страница 26: ...leshooting Until the Emulator Starts Up page 38 and remedy the troubles 2 Target status LEDs When the SAFE LED is lit the target status LEDs indicate the state of the target system The target status L...

Страница 27: ...f the emulator debugger 2 8 Setting the Operating Environment of Emulator Debugger M3T PD308M After starting up M3T PD308M as the Init dialog box will open set up as shown in Figure 2 13 For details o...

Страница 28: ...e 2 14 shows the window display when M3T PD308M starts up normally If an error has been detected and M3T PD308M has not started up refer to 5 1 Troubleshooting Until the Emulator Starts Up page 38 Fig...

Страница 29: ...ut the Target System 30 3 2 Using the Emulator with the Target System 30 3 3 Using the P87 XCIN Pin as a Port 30 3 4 Using the P87 XCIN Pin as Sub Clock Input 30 3 5 Selecting Clock Supply 31 1 Select...

Страница 30: ...er voltage select jumper is invalid 2 Connect the target system see page 22 Connect the LCC probe on the lower board of the emulator to the LCC socket option or the pitch converter board option 3 Conn...

Страница 31: ...lock by the Clock tab of the Init dialog box when starting up the emulator debugger or the CLK command input on the Script window For details refer to user s manual of the emulator debugger 1 Selectin...

Страница 32: ...he XIN pin And the XOUT pin should be open It is same for sub clock oscillator XCIN and XCOUT Figure 3 1 External oscillator circuit Make note of the fact that in the oscillator circuit shown in Figur...

Страница 33: ...3 2 Recommended oscillator Manufacturer Type name KINSEKI LIMITED JXO 5 series 1 Removing the oscillator Remove the oscillator mounted on the emulator The position of the oscillator see Figure 3 3 2...

Страница 34: ...34 52 MEMO...

Страница 35: ...35 52 Chapter 4 Specifications This chapter describes specifications of this product 4 1 Specifications 36 4 2 Connection Diagram 37 4 3 External Dimensions of the Emulator 38...

Страница 36: ...to 5 0 V supplied from the emulator Basic debugging functions Download S W break max 64 points Program execution stop allows free run execution supporting S W breaks Memory reference setting referenc...

Страница 37: ...00T CPE This connection diagram mainly shows the interface section and the circuits which are not connected to the target system such as the emulator s control system are omitted These signals are con...

Страница 38: ...38 52 Figure 4 2 External dimensions of the emulator 4 3 External Dimensions of the Emulator Figure 4 2 shows external dimensions of the emulator Unit mm...

Страница 39: ...Emulator Starts Up 40 1 Troubleshooting When the Emulator Starts Up 41 2 Troubleshooting When Emulator Debugger M3T PD308M Starts Up 42 5 2 Troubleshooting When Using Emulator Debugger M3T PD308M 43...

Страница 40: ...n the emulator Error detected in self checks Error detected Normal Initializing in the emulator VCC pin H CLK supply to the XIN pin normal Yes No BYTE pin L NMI pin H CNVss pin L Emulator internal fun...

Страница 41: ...does not work properly Check JP1 MCU power supply select jumper is set to the INT side Internal clock for XIN of the emulator does not oscillate properly Check the internal clock is mounted properly...

Страница 42: ...emulator is not working properly Check the settings as explained in 1 Troubleshooting When the Emulator Starts Up Check the connected serial port and the serial port settings in the Init dialog box ma...

Страница 43: ...system s oscillation circuit works properly Also if using the sub clock see 3 4 Using the P87 XCIN Pin as Sub Clock Input page 28 If the external clock supply is set change to internal supply Also if...

Страница 44: ...ing according to the error type For starting up the emulator after the self check shut off the power of the emulator and reactivate it For this self check it takes about 30 seconds XIN 20 MHz When sel...

Страница 45: ...aged Contact your local distributor Emulator does not work properly Check JP1 MCU power supply select jumper is set to INT side The internal clock for XIN of the emulator does not oscillate properly C...

Страница 46: ...46 52 MEMO...

Страница 47: ...r 6 Maintenance and Guarantee This chapter describes how to maintenance repair provisions and how to request for repair 6 1 Maintenance 48 6 2 Guarantee 48 6 3 Repair Provisions 48 6 4 How to Request...

Страница 48: ...leasing company or the owner 6 3 Repair Provisions 1 Repair with extra charge The products elapsed more than twelve months after purchase can be repaired with extra charge 2 Replacement with extra cha...

Страница 49: ...Repair Request Sheet to Renesas Solutions Corp Renesas Solutions When the faulty product is repaired it will be returned to the customer at the earliest convenience CAUTION Note on Transporting the P...

Страница 50: ...50 52 MEMO...

Страница 51: ...M30800T CPE User s Manual Rev 1 00 November 16 2003 REJ10J0271 0100Z COPYRIGHT 2003 RENESAS TECHNOLOGY CORPORATION AND RENESAS SOLUTIONS CORPORATION ALL RIGHTS RESERVED...

Страница 52: ......

Отзывы: