Emergency Procedures 6 - 7
Rev. 01 – 07-01-2008
6 Emergency
Procedures
6.11 In-Flight Engine Fire Procedure
1. Shut-off fuel flow by closing fuel valve
2. Push the throttle lever fully forward until engine stops
3. Try to extinguish the flames by a fast descent carried out as slip
4. Land as soon as possible
Notice:
Do not activate the rescue system!
6.12 Emergency Landing on Water
1. The final approach has to be carried out into the wind
2. Cut-off the ignition and close fuel valve
3. Eject
doors
4. Touch down on the water surface with minimum possible airspeed
5. Unbuckle and exit the aircraft immediately after touch down
6.13 Recovery from Unintended Spin
It is generally prohibited to carry out an intentional spin, but if an unintended spin has to
be recovered,
please follow the procedures below:
1. Move rudder and control surfaces to neutral position
2. Apply rudder against spin direction
3. After spin stops, apply elevator carefully to recover normal flight condition
Содержание G 2008 Series