REMKO MKT 250 Скачать руководство пользователя страница 8

REMKO MKT

9

CAUTION

■ 

The function of the device was precisely 
checked several times at the factory. If 
malfunctions that are not described in 
the “Trouble Shooting“ chapter (s. p. 
7) still appear, contact your dealer or 
contractual partner.

■ 

In order for REMKO to assume the 
warranty, the “Warranty Certificate“ 
included in delivery must be completely 
filled out and sent to REMKO GmbH & 
CO KG immediately after purchasing or 
commissioning.

Warranty

Electrical wiring diagram

The manufacturer is not li

-

able for damage that occurs 
due to nonobservance of 
manufacturer instructions or 
the legal requirements or due 
to unauthorised changes to 
the device.

Fig. 18  

Electrical wiring diagram

Technical dimensions and design sub

-

ject to alteration

 

Control panel

Evaporator fan

Condenser

Red

Orange

Yellow

White

Red

Red

Red

Blue

Blue

Blue

Blue

Condenser

Condenser

Compressor

Evaporator fan

Reservoir motor

Mains plug

White

Blue

White

Blue

Microswitch

Temperature 

sensor

J003

J002

J001

Hi

Med

Lo

RL101

L

N

E

J01

Brown

L

COMP

To take the device out of service,  
deactivate it first by pressing the “Power“ 
button. Then pull the mains plug.

If the device must be shut down for a
longer period of time, for example, for 
storage during the winter, observe the
following:

1. 

Let the machine run for about two 
hours in the “Fan“ mode to dry the sur-
face of the evaporator plate fins. In this 
way, the residual moisture is removed 
from the device and you can prevent 
unpleasant smells during recommission-
ing.

2. 

Switch off the device, pull the mains 
plug, and roll up the mains supply line.

3. 

Drain the condensate (s. p. 6).

Taking out of service

L

Содержание MKT 250

Страница 1: ...dify Mode Fan Mode Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environ...

Страница 2: ...ains supply line Protect all electrical lines of the device from damage even from animals Select the extension lines of the mains supply line depending on the connected load of the device the line len...

Страница 3: ...that the cooling effect can be maintained Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air...

Страница 4: ...splay 7 13 Green Set Temp LED 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys wi...

Страница 5: ...is pressed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer T...

Страница 6: ...ondensate Draining the condensate The condensate evaporates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects...

Страница 7: ...e and pull the mains plug 2 Place a flat tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug firmly The device is not cooling properly...

Страница 8: ...sign sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains plug Whit...

Страница 9: ...to the wall bushing To prevent cold bridges insulate the telescopic pipe with suitable insulating material Wall the telescopic pipe into the core hole in such a way that it is flush to both sides of t...

Страница 10: ...O MKT 11 Fig 20 Device diagram of the MKT 250 Technical dimensions and design subject to alteration 28 31 29 30 17 18 25 19 20 15 24 32 22 8 10 9 5 16 7 6 21 4 13 14 11 26 27 12 23 1 2 3 33 Device Dia...

Страница 11: ...824 15 Exhaust air pipe adapter 1106865 1106865 16 Condenser 1 5 F 1106866 1106866 17 Evaporator 1106894 1106894 18 Fan housing circulation air 1106822 1106822 19 Fan wheel circulation air 1106823 110...

Страница 12: ...ume approx m 80 Temperature setting range C 16 up to 32 Temperature operating limits C r F 16 bis 35 35 bis 85 Refrigerant R 410A Operating pressure max cooling circle kPa 1900 2800 Refrigerant quanti...

Отзывы: