Contact your dealer or 
contractual partner if the 
device cannot be com

-

missioned.

Never open the device 
housing.

Never perform work on 
the cooling circuit or the 
electrical equipment.

Trouble Shooting

The device is not functioning and the 
control panel remains dark. 

■ 

Make sure that 

  ·   the mains plug is properly inserted;

 

·   there is no power failure;

  ·   the mains voltage is present (fuse)

■ 

Check the mains supply line for damage.

The device is not functioning and the 
“Timer“ time delay LED is flashing.

■ 

“Timer“ time delay is programmed. 
Delete the timer setting.

The device is not functioning and 
“E1“ is being shown in the display. 

■ 

The room temperature lies outside the 
operating range of 16 to 35°C. Wait 
until the room temperature lies in the 
working range (reduce the incident of 
sunlight and close windows and doors, 
if necessary).

The device deactivates automatically.
The fault LED flashes and a signal sounds
(reservoir full).

To drain the reservoir, proceed as follows:

1. 

Switch off the device and pull the mains 
plug.

2. 

Place a flat tray under the condensate 
drain spout and remove the plug (Fig. 
17).

3. 

After the condensate has drained,  
reinsert the plug firmly.

The device is not cooling properly.

 

■ 

Check the mode: the “Cool“ LED must 
be lit.

■ 

For an optimum cooling capacity, close 
the curtains and blinds. In addition, 
make sure the windows and doors are 
closed.

■ 

Make sure that

·   the air outlet hose has been prop-

erly attached. It may not be bent, 
declining, or laid in a tight curve;

  ·   no foreign bodies impair the ex-  

   haust or intake air supply (observe  
   the minimum clearances); 

  ·   the air directing plate fins are free of  

   soiling or foreign objects

  ·   the set temperature is not too high  

   (operating limits of the device: 16  
   to 35°C).

The device does not react
to the remote control.

■ 

Make sure that

  ·   the batteries are functioning;    

   change them if necessary;

  ·   the batteries are inserted with the  

   correct polarity (cf. the marking); 
·   there are no objects between the  
   remote control and the device    
   (reach of approx. 5 m).

Condensate is emerging.

■ 

Make sure that

  ·   the device is on a horizontal    

   foundation;

 

·   the air outlet hose is properly at- 
   tached;

  ·   the plug is firmly inserted in the  

   condensate drain spout.

DANGER

Содержание MKT 250

Страница 1: ...dify Mode Fan Mode Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environ...

Страница 2: ...ains supply line Protect all electrical lines of the device from damage even from animals Select the extension lines of the mains supply line depending on the connected load of the device the line len...

Страница 3: ...that the cooling effect can be maintained Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air...

Страница 4: ...splay 7 13 Green Set Temp LED 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys wi...

Страница 5: ...is pressed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer T...

Страница 6: ...ondensate Draining the condensate The condensate evaporates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects...

Страница 7: ...e and pull the mains plug 2 Place a flat tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug firmly The device is not cooling properly...

Страница 8: ...sign sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains plug Whit...

Страница 9: ...to the wall bushing To prevent cold bridges insulate the telescopic pipe with suitable insulating material Wall the telescopic pipe into the core hole in such a way that it is flush to both sides of t...

Страница 10: ...O MKT 11 Fig 20 Device diagram of the MKT 250 Technical dimensions and design subject to alteration 28 31 29 30 17 18 25 19 20 15 24 32 22 8 10 9 5 16 7 6 21 4 13 14 11 26 27 12 23 1 2 3 33 Device Dia...

Страница 11: ...824 15 Exhaust air pipe adapter 1106865 1106865 16 Condenser 1 5 F 1106866 1106866 17 Evaporator 1106894 1106894 18 Fan housing circulation air 1106822 1106822 19 Fan wheel circulation air 1106823 110...

Страница 12: ...ume approx m 80 Temperature setting range C 16 up to 32 Temperature operating limits C r F 16 bis 35 35 bis 85 Refrigerant R 410A Operating pressure max cooling circle kPa 1900 2800 Refrigerant quanti...

Отзывы: