Spare Part List

When ordering spare parts, enter the serial of the device on the rating plate in addition to the Ref. no.

Accessories

No.

Designation

 

MKT 250

    MKT 250 

1

Unit bottom

1106850

1106850

2

Transport roller

1106851

1106851

3

Condensate pump

1106852

1106852

4

Condenser 2.5 µF (evaporator fan)

1106853

1106853

5

Float regulator (reservoir)

1106854

1106854

6

Cover (reservoir)

1106855

1106855

7

Microswitch (reservoir)

1106856

1106856

8

Compressor, cpl

1106891

1106891

9

Condenser 40 µF (compressor)

1106892

1106892

10

Evaporator

1106893

1106893

11

Fan housing (exhaust air)

1106860

1106860

12

Fan wheel (exhaust air)

1106861

1106861

13

Fan motor (exhaust air)

1106863

1106863

14

Condensate tray

1106824

1106824

15

Exhaust air pipe adapter

1106865

1106865

16

Condenser 1,5 µF

1106866

1106866

17

Evaporator

1106894

1106894

18

Fan housing (circulation air)

1106822

1106822

19

Fan wheel (circulation air)

1106823

1106823

20

Fan motor (circulation air)

1106843

1106843

21

Circuit board

1106873

1106873

22

Mains supply line with plug

1106874

1106874

23

Front wall

1106820

1106827

24

Back wall

1106829

1106829

25

Air outlet segment

1106844

1106844

26

PCB with control

1106825

1106825

27

Control panel

1106826

1106831

28

Air filter

1106830

1106830

29

Entry circuit

1106886

1106833

30

Connection pipe adapter

1106887

1106834

31

Window jet

1106888

1106835

32

Condensate drain spout with plug

1106882

1106882

33

Remote control

1106884

1106884

Air outlet hose, cpl. (nr. 29; 30; 31)

1106885

1106832

Spare parts without Abbildung 

 

Sensor (circulation air)

1106889

1106889

No.

Designation

 

MKT 250

    MKT 250 

Wall bushing

1613115

1613115

Содержание MKT 250

Страница 1: ...dify Mode Fan Mode Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environ...

Страница 2: ...ains supply line Protect all electrical lines of the device from damage even from animals Select the extension lines of the mains supply line depending on the connected load of the device the line len...

Страница 3: ...that the cooling effect can be maintained Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air...

Страница 4: ...splay 7 13 Green Set Temp LED 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys wi...

Страница 5: ...is pressed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer T...

Страница 6: ...ondensate Draining the condensate The condensate evaporates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects...

Страница 7: ...e and pull the mains plug 2 Place a flat tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug firmly The device is not cooling properly...

Страница 8: ...sign sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains plug Whit...

Страница 9: ...to the wall bushing To prevent cold bridges insulate the telescopic pipe with suitable insulating material Wall the telescopic pipe into the core hole in such a way that it is flush to both sides of t...

Страница 10: ...O MKT 11 Fig 20 Device diagram of the MKT 250 Technical dimensions and design subject to alteration 28 31 29 30 17 18 25 19 20 15 24 32 22 8 10 9 5 16 7 6 21 4 13 14 11 26 27 12 23 1 2 3 33 Device Dia...

Страница 11: ...824 15 Exhaust air pipe adapter 1106865 1106865 16 Condenser 1 5 F 1106866 1106866 17 Evaporator 1106894 1106894 18 Fan housing circulation air 1106822 1106822 19 Fan wheel circulation air 1106823 110...

Страница 12: ...ume approx m 80 Temperature setting range C 16 up to 32 Temperature operating limits C r F 16 bis 35 35 bis 85 Refrigerant R 410A Operating pressure max cooling circle kPa 1900 2800 Refrigerant quanti...

Отзывы: