REMKO MKT 250 Скачать руководство пользователя страница 3

4

Delivery

All devices are carefully packed 
before shipping. Please check the 
device immediately after delivery. 
Make a note of any damage or 
missing parts on the delivery note 
and inform the forwarding agent 
and your contractual partner. No 
warranty can be assumed for later 
complaints.

Erecting the device

■ 

Make sure that all air intake 
and air outlet openings are 
free; observe the minimum 
clearances (Fig. 2). 

■ 

Erect the device on a solid, 
even foundation (Fig. 3).

■ 

Make sure that people and 
sensitive objects such as plants 
are not directly affected by the 
emerging air. 

■ 

Connect the device to a 
properly installed plug socket 
(230V/50Hz) (Fig. 5). 

■ 

Insert the batteries into the 
remote control. To do so, 
push up the cover on the back 
side of the remote control 
and insert the batteries while 

observing the proper polarity. 
Observe the marking inside 
the compartment (Fig. 6).

■ 

Check whether the plug of the 
condensate drain spout has 
been provided and whether 
it has been properly inserted. 
There is otherwise a danger of 
water emerging.

Exhaust air conduction

During the operation of the air 
conditioner, the device creates 
humid exhaust air that must be 
conducted outside of the room 
so that the cooling effect can be 
maintained. 

Observe the following notices:   

■ 

Plug the air outlet hose in-
cluded in delivery onto the air 
outlet on the rear panel of the 
device.

■ 

Lock both catches on the air 
outlet into both openings of 
the air outlet hose.

■ 

Keep the air outlet hose as 
short as possible (max. length 
1400 mm). 

■ 

Always lay the air outlet 
hose with a constant upward 
incline from the device to the 
wall/window. Make sure it has 

a wide curve radius (Fig. 7). 

■ 

The air outlet hose may not be 
extended.

■ 

Pivot-hung windows
· 

Connect the air outlet hose to 

 

the window jet and the de-
vice. 

  · Open the window and lay the 

 flat nozzle between the win 

dow  trim and the window 
frame (Fig. 8).

■ 

Double-wing window 

Lay the flat nozzle between 
the wings, close the window 
as far as possible, and secure 
the wings with a holding strap 
(Fig. 9).

■ 

Wall bushing 

 

In case of permanent instal-
lation (s. p. 9, Fig. 19), the 
exhaust air from the device is 
conducted outside the room 
through the wall bushing  
(Fig. 10).

Device Structure

Fig. 10 

 Permanent installation 

with a wall bushing (accessory, 
not included in supply schedule)

Fig. 3 

 Vertical erection on 

solid, even foundation

Fig. 4 

 Five-minute “wait“

Fig. 5 

 230 V / 50 Hz

Fig. 6

  Remote control

Abb. 7

  Attach the air outlet 

hose with a constant upward 
incline

Fig. 8 

 Hanging the window jet 

into a pivot-hung window

Fig. 9 

 Secure the double-wing 

window using a holding strap.

Содержание MKT 250

Страница 1: ...dify Mode Fan Mode Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environ...

Страница 2: ...ains supply line Protect all electrical lines of the device from damage even from animals Select the extension lines of the mains supply line depending on the connected load of the device the line len...

Страница 3: ...that the cooling effect can be maintained Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air...

Страница 4: ...splay 7 13 Green Set Temp LED 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys wi...

Страница 5: ...is pressed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer T...

Страница 6: ...ondensate Draining the condensate The condensate evaporates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects...

Страница 7: ...e and pull the mains plug 2 Place a flat tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug firmly The device is not cooling properly...

Страница 8: ...sign sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains plug Whit...

Страница 9: ...to the wall bushing To prevent cold bridges insulate the telescopic pipe with suitable insulating material Wall the telescopic pipe into the core hole in such a way that it is flush to both sides of t...

Страница 10: ...O MKT 11 Fig 20 Device diagram of the MKT 250 Technical dimensions and design subject to alteration 28 31 29 30 17 18 25 19 20 15 24 32 22 8 10 9 5 16 7 6 21 4 13 14 11 26 27 12 23 1 2 3 33 Device Dia...

Страница 11: ...824 15 Exhaust air pipe adapter 1106865 1106865 16 Condenser 1 5 F 1106866 1106866 17 Evaporator 1106894 1106894 18 Fan housing circulation air 1106822 1106822 19 Fan wheel circulation air 1106823 110...

Страница 12: ...ume approx m 80 Temperature setting range C 16 up to 32 Temperature operating limits C r F 16 bis 35 35 bis 85 Refrigerant R 410A Operating pressure max cooling circle kPa 1900 2800 Refrigerant quanti...