background image

MKT 240

8

CAUTION

■ 

The function of the device was precisely 
checked several times at the factory. If 
malfunctions that are not described in 
the “Trouble Shooting“ chapter (s. p. 
7) still appear, contact your dealer or 
contractual partner.

■ 

In order for REMKO to assume the 
warranty, the “Warranty Certifi cate“ 
included in delivery must be completely 
fi lled out and sent to REMKO GmbH & 
CO KG immediately after purchasing or 
commissioning.

Warranty

Electrical wiring diagram

The manufacturer is not li-
able for damage that occurs 
due to nonobservance of 
manufacturer instructions or 
the legal requirements or due 
to unauthorised changes to 
the device.

Fig. 18  

Electrical wiring diagram

Technical dimensions and design sub-

ject to alteration

Evaporator fan

Condenser

Red

Orange

Yellow

White

W

W

Red

Red

Red

Blue

Blue

Blue

Blue

Condenser

Condenser

Compressor

Evaporator fan

Reservoir motor

Mains plug

White

Blue

White

Blu

e

Microswitch

Temperature 

sensor

J003

J00

2

J00

1

Hi Med Lo

L

N

E

Brown

COMP

To take the device out of service,  
deactivate it fi rst by pressing the “Power“ 
button. Then pull the mains plug.

If the device must be shut down for a
longer period of time, for example, for 
storage during the winter, observe the
following:
1.

Let the machine run for about two 
hours in the “Fan“ mode to dry the sur-
face of the evaporator plate fi ns. In this 
way, the residual moisture is removed 
from the device and you can prevent 
unpleasant smells during recommission-
ing.

2.

Switch off the device, pull the mains 
plug, and roll up the mains supply line.

3.

Drain the condensate (s. p. 6).

Taking out of service

Содержание MKT 240

Страница 1: ...Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environment and Recycling...

Страница 2: ...lines under carpeting Do not lay lines under carpeting Never operate the device with Never operate the device with out an air lter Never direct the air ow at Never direct the air ow at people Never op...

Страница 3: ...ed Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air outlet into both openings of the air ou...

Страница 4: ...D 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys with the same symbols have the...

Страница 5: ...ed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer Temp Adju...

Страница 6: ...porates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects conden sate in a reservoir If the permissible level...

Страница 7: ...and pull the mains plug 2 Place a at tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug rmly The device is not cooling properly Chec...

Страница 8: ...design sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White White W Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains...

Страница 9: ...480 mm with a diameter of at least 135 mm Take the minimum distance of 430 mm between the oor mounting surface of the device and the centre of the wall bushing into consideration Insert the telescopi...

Страница 10: ...of the MKT 240 Technical dimensions and design subject to alteration Device Diagram 28 28 35 35 33 33 34 34 18 18 29 29 19 19 21 31 31 18 18 18 18 20 30 27 25 25 8 1 2 3 10 7 7 6 6 11 5 9 4 23 23 13...

Страница 11: ...n wheel right circulation air 1106870 21 Fan motor circulation air 1106871 22 Side wall right 1106872 23 Circuit board 1106873 24 Mains supply line with plug 1106874 25 Front wall 1106875 26 Back wall...

Страница 12: ...setting range C 16 bis 32 Temperature operating limits C 16 bis 35 Refrigerant R 407 C Refrigerant quantity kg 0 770 Circulation air volume ow rate m3 h 230 260 300 Exhaust air volume ow rate Max m3...

Отзывы: