background image

MKT 240

7

6

5

Infrared

transmitter

4

1  On/off “Power“ button

  2  “Mode“ button
  3  “Fan Speed“ button
  4  “Timer“ button
5+6   Temperature/time setting buttons
 

  “Timer/Temp. Adjust“: 5 higher, 6 lower

  7  Display
  8  Red fault LED: Reservoir full (s. p. 7 Trouble Shooting)
 

  An acoustic and an optical signal indicate that the fl oat switch of the internal  

 

  reservoir has shut down the operation of the device. The acoustic signal dies   

 

  down after a short period of time, but the LED remains active.

  9  Mode LED
 

  Green: “Cool“

 

  Orange: “Dehumidify“ 

 

  Yellow: “Fan“

  10  Orange LED for the fan speed, with high/medium/low speed “High“/“Med“/ 

 

  “Low“

11  Green LED for the time delay, “Timer“

  12  Green “Room Temp“ LED
 

  (If this LED lights up the current room temperature is shown in the display (7))

13  Green “Set Temp“ LED

  14  “°C/°F“ toggle button (only on the remote control)

Operation

The device is operated comfortably using 
the control panel on the device or the in-
frared remote control. Keys with the same 
symbols have the same function.

Mode“ selection (2)

■ 

“Cool“
The device is used to cool the room. It fi lters 
and dehumidifi es the air and thus creates a 
pleasant room climate.

■ 

“Dehumidify“
In the “Dehumidify“ mode, humidity is 
removed from the air.  

■ 

“Fan“
The device circulates the air, fi lters it, and 
creates an even air fl ow.

1

2

3

Infrared

receiver

4

5

6

7

12

10

9

8

11

13

Fig. 11

Control panel

Fig. 12

Infrared remote control

■ 

Point the infrared transmitter of the 
remote control at the infrared receiver 
on the control panel. 

■ 

In order for the signal to be received 
without interference, there should be 

no objects between the remote control 
and the device (reach of approx. 5 m).

■ 

The proper reception of the signal is 
indicated acoustically.

Содержание MKT 240

Страница 1: ...Timer Functional Principle of the Cooling Process Maintenance and Care Cleaning the Filter Draining the Condensate Trouble Shooting Taking the Device Out of Service Warranty Environment and Recycling...

Страница 2: ...lines under carpeting Do not lay lines under carpeting Never operate the device with Never operate the device with out an air lter Never direct the air ow at Never direct the air ow at people Never op...

Страница 3: ...ed Observe the following notices Plug the air outlet hose in cluded in delivery onto the air outlet on the rear panel of the device Lock both catches on the air outlet into both openings of the air ou...

Страница 4: ...D 14 C F toggle button only on the remote control Operation The device is operated comfortably using the control panel on the device or the in frared remote control Keys with the same symbols have the...

Страница 5: ...ed the display switches from the room temperature to the set tempera ture LED 13 lights up and shows the desired temperature for 15 seconds 7 Set the desired room temperature using the Timer Temp Adju...

Страница 6: ...porates during operation and is then conducted outside with the exhaust air via the air outlet hose In case of extreme humidity the device collects conden sate in a reservoir If the permissible level...

Страница 7: ...and pull the mains plug 2 Place a at tray under the condensate drain spout and remove the plug Fig 17 3 After the condensate has drained reinsert the plug rmly The device is not cooling properly Chec...

Страница 8: ...design sub ject to alteration Control panel Evaporator fan Condenser Red Orange Yellow White White W Red Red Red Blue Blue Blue Blue Condenser Condenser Compressor Evaporator fan Reservoir motor Mains...

Страница 9: ...480 mm with a diameter of at least 135 mm Take the minimum distance of 430 mm between the oor mounting surface of the device and the centre of the wall bushing into consideration Insert the telescopi...

Страница 10: ...of the MKT 240 Technical dimensions and design subject to alteration Device Diagram 28 28 35 35 33 33 34 34 18 18 29 29 19 19 21 31 31 18 18 18 18 20 30 27 25 25 8 1 2 3 10 7 7 6 6 11 5 9 4 23 23 13...

Страница 11: ...n wheel right circulation air 1106870 21 Fan motor circulation air 1106871 22 Side wall right 1106872 23 Circuit board 1106873 24 Mains supply line with plug 1106874 25 Front wall 1106875 26 Back wall...

Страница 12: ...setting range C 16 bis 32 Temperature operating limits C 16 bis 35 Refrigerant R 407 C Refrigerant quantity kg 0 770 Circulation air volume ow rate m3 h 230 260 300 Exhaust air volume ow rate Max m3...

Отзывы: