Fig. 27: Heating curve adjustment
1: Temperature of the heating water in °C
2: Inlet temperature heating curve
3: Return flow heating curve
4: Outside temperature in °C
For optimal configuration of the heating curve
parameters, the heating load calculation and/or
energy consumption must be taken into account.
Differences between the installed parameters and
the design of the actual building can cause the
heat pump to run inefficiently.
Operating the heating cycle with a fixed value is
not recommended, as it will cause the heat pump
to operate inefficiently.
Setting the heating curve:
- Activate the base point with the right softkey, set
with the rotary knob and conform with the right
softkey.
Base point
Fig. 28: Setting the base point
- The standard inlet temperature and the outside
temperature are set using the same procedure.
Standard flow temp.
Fig. 29: Setting the standard inlet temperature
Fig. 30: Setting the outside temperature
Fixed-value-control heating cycle mode
Specify the set temperature for fixed value control
(select with the rotary knob and confirm with "OK").
The heating cycle is kept permanently at this tem-
perature in fixed value control.
Press "Next".