"Settings" menu item (continued) - User
Authorisa-
tion level
Level 2 menu
item
Level 3 menu item
Level 4 menu item
Info
Heat pump
Graduated tariff
Number of power tariffs
You can find
many of the indi-
vidual info texts
about the level
2-4 menu items
on your Smart
Control
Time field Tariff 1-9
Power tariff 1-9
PV current
Consumption
Power tariff 1
Feed-in tariff
Personal use tariff
Legend: Parameter/unit series coding
*)
Unit series
*1)
Only WKF/WKF-compact
*2)
Only HTS
*3)
Only WKF/WKF-compact with F-board WKF/WKF-compact 70 built as of 2016
(WKF/WKF-compact 120-180 built as of 2015)
*4)
Only WKF/WKF-compact with A/C board (WKF/WKF-compact 85 with software version
³
4.19 and
WKF/WKF-compact 120-180 before 2015 with software version
³
4.19)
*5)
Only WKF Duo
"Messages" menu item
Pressing "OK" (right softkey) takes you to sub-
menus of the menu item "Messages".
This is where operating messages, warning
notices and fault messages are displayed.
Explanation of symbols:
Warning message
Fault message
If one of these symbols appears in the header of
the control screen, please access the menu item
"Messages" and display the details, with instruc-
tions on how to rectify the fault, with the key on the
right.
Operating messages indicate which of the regular
operating statuses the system is in.
3.2 Setting the heating curves
Heating curve heating cycle mode
The heating curve can be adjusted in three points,
according to the structure and location-related con-
ditions of the building:
Base point:
The base point corresponds to the minimum set
temperature of the heating water at an outside
temperature of 20 °C. If the heating is too cold at
relatively high outside temperatures (trans-sea-
sonal period), the base point should be set higher.
Standard inlet temperature:
the standard inlet temperature corresponds to the
set temperature of the heating water at the
standard outside temperature in the building loca-
tion. If the heating is not warm enough at low out-
side temperatures, the standard inlet temperature
should be increased.
Standard outside temperature:
the standard outside temperature is dependent on
the regional location of the building. Please consult
your heating installer.