REMKO HTL 200-EC/250-EC
Safety notes
■
The units may only be operated
by persons that have been
instructed in their operation
■
The units must be installed and
operated in such a way that
personnel are not endangered
by exhaust, warm air and
radiant heat and no fires can
occur
■
The units must be installed in
a stable position.
■
The units must then only
be operated in areas where
the units can be supplied with
an adequate amount of air
for the combustion
■
If the units are being operated
without exhaust gas routing
then they may only be operated
in well-ventilated areas.
Under such circumstances
it is forbidden for personnel
to remain in these areas for
extended periods.
Appropriate prohibition
signs should be put up at
the entrances
■
A safety zone of 1.5 m should
be maintained around the units
- incl. non-combustible items
■
The units may only be installed
on a level and non-combustible
surface
■
The units must not be installed
or operated in potentially
flammable or explosive
environments
■
All electrical cables for the units
must be protected against
damage (e.g. by animals etc.)
■
The units must not be exposed
to direct jets of water
e.g. pressure washers etc.
■
Portable fuel containers may
only be installed if they comply
with the technical rules for
combustible liquids “TRbF 210
and 280”
■
The protective grid of the unit's
intake must always be kept free
of dirt and loose objects
■
Never insert foreign objects into
the units
■
The power plug must be pulled
out of the mains socket before
the start of work on the unit
as a matter of principle
■
Safety devices must not
be bypassed or disabled
■
The personnel tasked with
operating the units must check
the units for visible defects
on the operating and safety
devices as well as the presence
of the protective devices
at the start of work.
If defects are discovered
these must be reported
to the supervisor
As a matter of principle, always
observe the respective local building
code and fire prevention guidelines as
well as the guidelines of the accident
prevention and insurance associations
when using the unit.
The units may never
be disconnected from the mains
prior to the completion
of the follow-up cooling phase
(except in emergencies).
CAUTION
The units are not designed
for use as a fixed installation.
NOTE
NOTE
Only type-approved forced-
air oil burners in WLE design
per DIN 4787 and DIN EN 267
should be used.
Unit description
NOTE
For optimum operation
the units should not
be operated above an ambient
temperature of 25 °C.
■
In the case of defects that
endanger the operational safety
of the unit, it must be taken out
of service immediately
■
The units should be checked
as required in accordance
with the operating conditions.
However, they must be
checked at least once a year
by a specialist to ensure that
they are in a condition that
is safe to use.
The exhaust gas values for
the burners must be checked
■
The units may only be operated
for room heating with a room
thermostat (accessory)
ATTENTION
The units must only
be installed in well ventilated
spaces and not in living areas
or similar recreational areas.