Installation example - hydraulic circuit diagram heat pump package HTS Stuttgart
The following hydraulic circuit diagrams are only to be used as a planning aid, and do not replace an installa-
tion drawing! The design and planning of customer-provided hydraulic systems must be performed by a
specialist installer!
NOTICE!
This diagram is not suitable for the units HTS 70 and HTS 100!
S 08
ZWP
EWS
A
B
1
2
3
4
C
A: Outdoor unit(s)
B: Indoor unit
C: EWS Storage tank
1: Cooling cycle
2: Mixed heating cycle
3: Hot water
4: Cold water
8
Flange heating cartridge
electrical wiring
n
The hot water tank must be filled with water
before being put into service.
n
A mains connection must be installed and
appropriately fused according to the circuit dia-
gram affixed in the terminal box for the unit.
n
A residual current circuit breaker with a tripping
current of I
∆N
≤ 30mA must be located
upstream of the supply circuit.
n
All cables and wires to and from the unit must
be fixed in place.
n
The unit must have an upstream-connected
isolating device for all poles, with a contact
opening of at least 3 mm (e.g. a circuit
breaker).
n
The unit’s electrical protection must be imple-
mented in accordance with the technical data.
DANGER!
All electrical installation work is to be performed
by specialist companies. Disconnect the power
supply when connecting the electrical terminals.
21