REMKO ETF 360/460

Safety notes

Condensation heat

The Energy transferred to the air 
from the condenser consists of:
1.  The amount of heat derived 

beforehand in the evaporator.

2. The electrical drive energy.
3.  The condensation heat released 

by liquefying the water vapour. 

Energy must be supplied when 
liquid is converted into a gas. 
This energy is designated as 
evaporation heat. It does not 
cause any increase in temperature, 
but is required to convert a liquid 
into a gas. Conversely, energy is 
released when gas is liquefied, 
this is designated as condensation 
heat. 

The amount of energy from 
evaporation heat and condensation 
heat is the same.   

For water, this is:  
2250 kJ/kg (4.18 kJ = 1kcal)

From this it is evident that the 
condensation of water vapour 
causes a large quantity of energy 
to be released.
If the moisture that it is to be 
condensed is not introduced by 
evaporation in the room itself, 
but from outside, e.g. through 
ventilation, the condensation 
heat released contributes to 
the heating of the room. With 
drying operations, a heat cycle 
is created, whereby heat is 
consumed for evaporation 

and released for condensation. 
When dehumidifying fed air, 
a larger contribution of heat is 
created, which manifests itself as 
a temperature increase. 

Generally speaking, the time 
required for the drying process is 
not only dependent on the output 
of the unit, but is determined to 
a greater extent by the speed at 
which the material or building 
section loses its moisture.

 

The units have been subjected to 
extensive material, functional and 
quality inspections prior to delivery.

However, dangers can result 
from the units if they are used 
improperly or not as intended by 
untrained personnel.

The following notes 
must be observed in full:

■ 

The units may not be installed 
or operated in explosive 
environments

■ 

The units must not be installed 
or operated in atmospheres 
containing oil, sulphur, chlorine, 
salt or dust

■ 

Never stick foreign objects into 
the units

■ 

The units must not be exposed 
to direct jets of water

■ 

An unobstructed air inlet and 
air outlet must be guaranteed 
at all times

■ 

The air-inlet grille must always 
be kept free of dirt and loose 
objects

■ 

The units must not be covered 
during operation

■ 

The units must be installed 
upright and in a stable position

■ 

The units must not be 
transported while they are 
running

■ 

The units may only be 
transported upright (water will 
escape otherwise)

■ 

All electrical cables on the 
outside of the units must be 
protected against damage (e.g. 
by animals etc.)

■ 

Before each change of location, 
the condensate container must 
be emptied

CAuTiOn

Extensions to the connection 
cable must only be conducted 
by authorised specialist 
electricians, taking into 
consideration the unit power 
consumption, cable length and 
local use.

CAuTiOn

Work on the refrigerant 
system and on the electrical 
equipment must only be 
conducted by a specially-
authorised specialist! 

Содержание ETF 360

Страница 1: ...Edition GB N01 REMKO ETF 360 ETF 460 Mobile dehumidifiers Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...the unit itself Subject to modifications no liability accepted for errors or misprints Air dehumidification 4 6 Safety notes 6 Unit description 7 Set up 8 Commissioning 8 11 Shutdown 11 Unit transpor...

Страница 4: ...vapour released from parts of a building or materials is absorbed by the surrounding air As a result the moisture content increases which ultimately gives rise to corrosion mould rot peeling of paint...

Страница 5: ...he temperature to fall below it Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m T...

Страница 6: ...of the unit but is determined to a greater extent by the speed at which the material or building section loses its moisture The units have been subjected to extensive material functional and quality...

Страница 7: ...inserted Dehumidification mode then starts after a switch on delay of around 3 minutes depending on the requirements In unattended continuous operation with an external condensate connection the cond...

Страница 8: ...elative humidity and observance of the set up instructions Wall clearance min 0 5 m Maintain adequate clearance from heaters or other sources of heat Keep windows and doors closed Schematic depiction...

Страница 9: ...dual current device provided by the customer in accordance with the regulations Note In room temperatures below 10 C and relative humidity below 40 economical use of the unit can no longer be guarante...

Страница 10: ...FF switching functions for up to 24 hours in 1 hour cycles Timer switching functions Setting in running operation After the selected number of hours the unit switches OFF Setting if the unit is switch...

Страница 11: ...that the drainage hose is placed at an incline to the drain to allow the condensate to drain without hindrance Caution After you plug in the adapters SA the pump is immediately ready for operation an...

Страница 12: ...ontamination on a regular basis Clean or replace if required Care and maintenance Regular care and maintenance is fundamental to a long service life and fault free operation of the unit Cleaning the c...

Страница 13: ...ay be remedied by washing the filter F in a lukewarm max 40 C soap solution Finally always rinse the filter carefully with clear water and allow to dry 7 Also check the intake grill G for contaminatio...

Страница 14: ...specially authorised specialist Caution The unit is loud or condensate runs out Check whether the unit is on a stable and even base Check whether the unit is standing upright and stably Have the conde...

Страница 15: ...re environmentally friendly and can be recycled By recycling packaging materials you make a valuable contribution to the reduction of waste and conservation of raw materials Therefore only dispose of...

Страница 16: ...it We reserve the right to modify the dimensions and design as part of the ongoing technical development process 46 36 35 43 42 41 39 44 45 37 06 03 01 08 02 02 04 05 02 18 19 28 31 20 17 16 15 29 32...

Страница 17: ...111865 1111865 17 Fan motor 1111866 1111866 18 Fan support plate 1111867 1111867 19 Support plate top 1111868 1111868 20 Exhaust grille 1111869 1111869 22 Fin condenser 1111870 1111870 23 Fin vaporise...

Страница 18: ...leaned Fan function checked Air inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check Test run 1 Date Signature 2 Date Sign...

Страница 19: ...es Max min airflow volume m3 h 320 280 310 270 Condensate container capacity l 6 5 6 5 Condensate pump Built in Built in Hose length condensate pump m 5 10 5 10 Delivery height condensate pump m 5 5 R...

Страница 20: ...more than just an excellent reliable supplier REMKO a partner who helps to solve problems Sales REMKO offers not just a well established sales network both nationally and internationally but also has...

Отзывы: