REMKO ETF 360 Скачать руководство пользователя страница 17

17

Spare parts list

When ordering replacement parts, please always state the EDP no. and unit number (see name plate)!

no.

Designation

ETF 360

ETF 460

EDP:

EDP:

01

Base plate

1111738

1111738

02

Conveyor rollers

1111851

1111851

03

Compressor, cpl.

1111852

1111853

04

Mains cable with plug 

1111854

1111854

05

Connection adapter (for condensate pump operation)

1111855

1111855

06

Condensate hose, linear m. (for condensate pump operation)

1111856

1111856

07

Complete connection panel (for condensate pump operation)

1111857

1111857

08

Condensate pump

1111858

1111858

09

Complete float (for condensate pump operation)

1111859

1111859

10

Microswitch (for condensate pump operation)

1111860

1111860

12

Solenoid valve, cpl.

1111823

1111823

13

Dry filter

1111862

1111862

14

Back wall 

1111863

1111863

15

Fan housing

1111864

1111864

16

Fan wheel

1111865

1111865

17

Fan motor

1111866

1111866

18

Fan support plate

1111867

1111867

19

Support plate, top 

1111868

1111868

20

Exhaust grille

1111869

1111869

22

Fin condenser

1111870

1111870

23

Fin vaporiser

1111871

1111872

24

Guide rails (set)

1111873

1111873

26

Temperature probe

1111843

1111843

27

Bracket for temperature sensor

1111875

1111875

28

Air filter

1111876

1111876

29

Unit front wall

1111877

1111877

30

Sensor board (humidity)

1111844

1111844

31

Operating board

1111845

1111845

32

Control panel (film)

1111880

1111880

35

Float housing 

1111881

1111881

36

Float

1111882

1111882

37

Condensate container cpl.

1111883

1111883

38

Centre wall

1111884

1111884

39

Condenser (fan motor) 

1111885

1111885

40

Protective housing (condenser)

-

-

41

Microswitch bracket  

1111887

1111887

42

Microswitch

1111888

1111888

43

Condenser (compressor)

1111889

1111890

44

Board housing

1111836

1111836

45

Cover (board housing)

1111837

1111837

46

V2 control board with fan stop

1111846

1111846

Not 

illustrated

Fuse  

(on the control board)

1111895

1111895

Содержание ETF 360

Страница 1: ...Edition GB N01 REMKO ETF 360 ETF 460 Mobile dehumidifiers Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...the unit itself Subject to modifications no liability accepted for errors or misprints Air dehumidification 4 6 Safety notes 6 Unit description 7 Set up 8 Commissioning 8 11 Shutdown 11 Unit transpor...

Страница 4: ...vapour released from parts of a building or materials is absorbed by the surrounding air As a result the moisture content increases which ultimately gives rise to corrosion mould rot peeling of paint...

Страница 5: ...he temperature to fall below it Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m T...

Страница 6: ...of the unit but is determined to a greater extent by the speed at which the material or building section loses its moisture The units have been subjected to extensive material functional and quality...

Страница 7: ...inserted Dehumidification mode then starts after a switch on delay of around 3 minutes depending on the requirements In unattended continuous operation with an external condensate connection the cond...

Страница 8: ...elative humidity and observance of the set up instructions Wall clearance min 0 5 m Maintain adequate clearance from heaters or other sources of heat Keep windows and doors closed Schematic depiction...

Страница 9: ...dual current device provided by the customer in accordance with the regulations Note In room temperatures below 10 C and relative humidity below 40 economical use of the unit can no longer be guarante...

Страница 10: ...FF switching functions for up to 24 hours in 1 hour cycles Timer switching functions Setting in running operation After the selected number of hours the unit switches OFF Setting if the unit is switch...

Страница 11: ...that the drainage hose is placed at an incline to the drain to allow the condensate to drain without hindrance Caution After you plug in the adapters SA the pump is immediately ready for operation an...

Страница 12: ...ontamination on a regular basis Clean or replace if required Care and maintenance Regular care and maintenance is fundamental to a long service life and fault free operation of the unit Cleaning the c...

Страница 13: ...ay be remedied by washing the filter F in a lukewarm max 40 C soap solution Finally always rinse the filter carefully with clear water and allow to dry 7 Also check the intake grill G for contaminatio...

Страница 14: ...specially authorised specialist Caution The unit is loud or condensate runs out Check whether the unit is on a stable and even base Check whether the unit is standing upright and stably Have the conde...

Страница 15: ...re environmentally friendly and can be recycled By recycling packaging materials you make a valuable contribution to the reduction of waste and conservation of raw materials Therefore only dispose of...

Страница 16: ...it We reserve the right to modify the dimensions and design as part of the ongoing technical development process 46 36 35 43 42 41 39 44 45 37 06 03 01 08 02 02 04 05 02 18 19 28 31 20 17 16 15 29 32...

Страница 17: ...111865 1111865 17 Fan motor 1111866 1111866 18 Fan support plate 1111867 1111867 19 Support plate top 1111868 1111868 20 Exhaust grille 1111869 1111869 22 Fin condenser 1111870 1111870 23 Fin vaporise...

Страница 18: ...leaned Fan function checked Air inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check Test run 1 Date Signature 2 Date Sign...

Страница 19: ...es Max min airflow volume m3 h 320 280 310 270 Condensate container capacity l 6 5 6 5 Condensate pump Built in Built in Hose length condensate pump m 5 10 5 10 Delivery height condensate pump m 5 5 R...

Страница 20: ...more than just an excellent reliable supplier REMKO a partner who helps to solve problems Sales REMKO offers not just a well established sales network both nationally and internationally but also has...

Отзывы: