REMKO ETF 360 Скачать руководство пользователя страница 20

Hotline

 

Germany 

+49 5232 606-0 

International 

+49 5232 606-130

REMKO GmbH & Co. KG 
Air conditioning and heating technology 

Im Seelenkamp 12  

D-32791 Lage 

Postfach 1827   

D-32777 Lage

Telephone 

 

+49 5232 606-0

Fax 

 

 

+49 5232 606-260

E-mail   

 

[email protected]

Internet 

 

www.remko.de

W

e r

eserve the right to make technical changes and pr

ovide no warranty as to the accuracy of this data!

Consultation

Thanks to intensive training, 
our consultants are always 
completely up-to-date when it 
comes to technical expertise. 
This has given us the reputation 
of being more than just 
an excellent, reliable supplier:  
REMKO, a partner who helps to 
solve problems.

 

Sales

REMKO offers not just a well 
established sales network both 
nationally and internationally, but 
also has exceptionally highly-
qualified sales specialists.  
REMKO employees in the 
field are more than just sales 
people: above all, they must 
be advisers to our customers 
in air conditioning and heating 
technology. 

 

Customer service

Our units operate precisely and 
reliably. However, in the event of 
a malfunction REMKO customer 
service is quickly on the scene. 
Our comprehensive network of 
experienced dealers guarantees 
quick and reliable service.

REMKO inTERnATiOnAl

... and also right in your neighbourhood!

Take advantage of our experience and advice

Содержание ETF 360

Страница 1: ...Edition GB N01 REMKO ETF 360 ETF 460 Mobile dehumidifiers Operation Technology Spare parts...

Страница 2: ......

Страница 3: ...the unit itself Subject to modifications no liability accepted for errors or misprints Air dehumidification 4 6 Safety notes 6 Unit description 7 Set up 8 Commissioning 8 11 Shutdown 11 Unit transpor...

Страница 4: ...vapour released from parts of a building or materials is absorbed by the surrounding air As a result the moisture content increases which ultimately gives rise to corrosion mould rot peeling of paint...

Страница 5: ...he temperature to fall below it Building materials and structures are capable of absorbing considerable volumes of water such as brick 90 190 l m heavy concrete 140 190 l m and limestone 180 270 l m T...

Страница 6: ...of the unit but is determined to a greater extent by the speed at which the material or building section loses its moisture The units have been subjected to extensive material functional and quality...

Страница 7: ...inserted Dehumidification mode then starts after a switch on delay of around 3 minutes depending on the requirements In unattended continuous operation with an external condensate connection the cond...

Страница 8: ...elative humidity and observance of the set up instructions Wall clearance min 0 5 m Maintain adequate clearance from heaters or other sources of heat Keep windows and doors closed Schematic depiction...

Страница 9: ...dual current device provided by the customer in accordance with the regulations Note In room temperatures below 10 C and relative humidity below 40 economical use of the unit can no longer be guarante...

Страница 10: ...FF switching functions for up to 24 hours in 1 hour cycles Timer switching functions Setting in running operation After the selected number of hours the unit switches OFF Setting if the unit is switch...

Страница 11: ...that the drainage hose is placed at an incline to the drain to allow the condensate to drain without hindrance Caution After you plug in the adapters SA the pump is immediately ready for operation an...

Страница 12: ...ontamination on a regular basis Clean or replace if required Care and maintenance Regular care and maintenance is fundamental to a long service life and fault free operation of the unit Cleaning the c...

Страница 13: ...ay be remedied by washing the filter F in a lukewarm max 40 C soap solution Finally always rinse the filter carefully with clear water and allow to dry 7 Also check the intake grill G for contaminatio...

Страница 14: ...specially authorised specialist Caution The unit is loud or condensate runs out Check whether the unit is on a stable and even base Check whether the unit is standing upright and stably Have the conde...

Страница 15: ...re environmentally friendly and can be recycled By recycling packaging materials you make a valuable contribution to the reduction of waste and conservation of raw materials Therefore only dispose of...

Страница 16: ...it We reserve the right to modify the dimensions and design as part of the ongoing technical development process 46 36 35 43 42 41 39 44 45 37 06 03 01 08 02 02 04 05 02 18 19 28 31 20 17 16 15 29 32...

Страница 17: ...111865 1111865 17 Fan motor 1111866 1111866 18 Fan support plate 1111867 1111867 19 Support plate top 1111868 1111868 20 Exhaust grille 1111869 1111869 22 Fin condenser 1111870 1111870 23 Fin vaporise...

Страница 18: ...leaned Fan function checked Air inlet grid with filter cleaned Unit checked for damage Safety devices checked All fastening screws checked Electrical safety check Test run 1 Date Signature 2 Date Sign...

Страница 19: ...es Max min airflow volume m3 h 320 280 310 270 Condensate container capacity l 6 5 6 5 Condensate pump Built in Built in Hose length condensate pump m 5 10 5 10 Delivery height condensate pump m 5 5 R...

Страница 20: ...more than just an excellent reliable supplier REMKO a partner who helps to solve problems Sales REMKO offers not just a well established sales network both nationally and internationally but also has...

Отзывы: