5.7 Wall bracket for the indoor unit
A
B
D
G
C
E
F
H
Fig. 26: Mounting points for the wall bracket BL 263-353 DC IT (rear view, all dimensions in mm)
Unit type /
dimensions
A
B
C
D
E
F
G
H
BL 263 DC IT
350
365
45
47
115
213
548
167
BL 353 DC IT
395
410
44
47
115
245
580
225
(All dimensions in mm)
The diameter of the pipe break-through is 65 mm for all units types.
The wall bracket for the units must be attached with suitable screws and anchors.
6
Installation
6.1 Installation of the indoor unit
The indoor unit is attached by means of a wall
bracket, taking into consideration the air outlet side
located in the lower part.
1.
Mark the mounting points on the structurally
permissible building sections according to the
dimensions of the wall bracket.
2.
If necessary, remove the break out opening
of the housing.
3.
Connect the refrigerant piping, electrical
cables and condensate drainage line to the
indoor unit as described below.
4.
Hang the indoor unit onto the wall bracket by
tilting it back slightly and by pressing the
bottom part of the unit against the bracket.
5.
Check again that the unit is level. (Fig. 27)
Fig. 27: Horizontal positioning
The wall bracket for the units must be attached
with suitable screws and anchors.