changed via a LAN connection to the internal net-
work, using a remote computer with internet
access. The following is an example of configuring
the parameters within this menu. Setting ATR-
Smart-Web to the following parameters:
Name
ID name
Username
Admin
Password
Admin
Local address
192.168.0.140
Gateway
0.0.0.0
Netmask
255.255.255.0
Local port
80
MAC address
xx:xx:xx:xx:xx:xx
To change the parameters within the sections:
"LOCAL ADDRESS", "GATEWAY" and "NET-
MASK", select one of the input fields to activate
it, delete the existing value with the
X
key
and then enter the desired value. Press "OK" to
confirm and save the entry.
To activate the changes within the
"ETHERNET" section, the electrical power must
be disconnected and reconnected at the room
temperature controller.
Then, after connecting ATR-Smart-Web to the net-
work, open the internet browser and enter the fol-
lowing character string:
http://192.168.0.140
The screen page of the web interface appears on
your own computer allowing the management of
the parameters of the ATR-Smart-Web.
The MAC address for the ATR-Smart-Web used
is shown in the "ETHERNET" menu.
10:15
Mon 01 Jan
Ethernet
Rücksetzung auf Werkseinstellung
RS485
System
OK
Ethernet
10:15
Mon 01 Jan
Ethernet
Name
Username
Passwort
Lokale Adresse
OK
Lokale Adresse
10:15
Mon 01 Jan
Lokale Adresse
OK
1
2
0
3
4
5
6
7
8
9
X
000
192
168
140
Systemkonfiguration
System
System configuration
Reset to factory setting
Ethernet
Local address
Password
Local address
Local address
Fig. 12: Set Ethernet
15