Malfunction-free operation is guaranteed if the exhaust 
system is installed in an ascending direction and with 
vertical end pipes. 
The exhaust system must terminate at least above the 
height of the eaves but better still above roof height in 
order to avoid counter pressure caused by weather-
related circumstances (e.g. wind). 
All exhaust-pipe parts must be attached reliably. Their 
diameter must not be smaller than that of the exhaust 
nozzle of the device (

 150 mm). 

The minimum distance of 0.6 m to combustible parts 
must not be exceeded. 
Exhaust-pipe parts including attachment material are 
available as accessories. 

Exhaust system 

 

In the outdoors or in open rooms, the operation of the 
device is also possible without an exhaust system. 
However, we recommend a 1 m exhaust-pipe (see ex-
ample 2) with a rain hood placed on top so as to rule out 
the penetration by rainwater and dirt. 
If the device is used for temporary room heating, the 
combustion gases may have to be removed to the exte-
rior. The exhaust-pipe parts must be laid in such a way 
that a minimum suction of 0.1 mbar is guaranteed. 

G

 

It must be made sure in all cases that counter 
pressure due to an incorrect exhaust system is 
ruled out. 

Example 1

 

Example 2

 

Example 3

 

operating with  

extended 

waste gas pipe 

condensate trap  

necessarily

 

operating without  

extended 

waste gas pipe 

max. 1m

 

Inadmissible 

arrangement.

 

Important hint. 

Make sure that the waste gas pipes are correctly in-
stalled with a condensate trap (see example 1), to avoid 
damage to the combustion chamber through humidity 
deposits (condensate) (see example 3). 
The lateral openings in the exhaust connection must not 
be closed or covered. 

Installation Instructions

 

 
The units are generally to be operated in accordance  
with the safety rules, the building code of the land con-
cerned and the fire protection code. 

Avoid under or overpressure in the room where the 
unit is installed, as this would result in combustion 
troubles. 

Suction and blow-out cross sections may not be re-
duced 

It is prohibited to connect conduits or hoses to the 
unit blow-out opening. 

Make sure that the technical regulations for combus-
tible liquids are observed when mobile fuel holders 
are installed. 

Outside Installation

 

The units are to be installed outside and to be pro-
tected from atmospheric effects to avoid damage. 

Make sure that no danger or inadmissible annoy-
ance is caused by the operation of the unit. 

Room Heating 

For room heating, hot air generators may only be op-
erated with a room thermostat (accessories). 

Make sure that sufficient fresh air is fed to ensure  
perfect combustion. Fresh air is to be fed preferably 
through windows and doors or through sufficiently di-
mensioned openings in the outer wall. 

Safety Distances 

Make sure to observe the following safety distances 
to ensure a safe operation of the unit: 

      –    towards the top, fire-retarding ceiling            1,5 m 

      –    towards the sides, non-burning objects         0,6 m 

      –    blow-off side, with non-burning objects         3,0 m 

      –    suction side, for perfect air supply                 1,0 m 

The floor and the ceiling must be from fire-retarding 
materials. 

Electric Connection 

The unit are operated with 230 V alternating current. 

Electric connection is carried out via a fitted mains 
cable with shockproof plug. 

Possibly required extension cables must be selected 
according to the existing cable length, the unit’s con-
necting line and the intended purpose. 

G

 

The electric connection of the unit is to be carried 
out via a special supply point with fault current 
safety switch. 

G

 

All extension cables are to be used only after 
having been removed from the roller.

 

Содержание AT 25

Страница 1: ...REMKO powerful like a bear Edition GB M04 Operation Technology Spare Parts REMKO AT 25 Automatic oil heater ...

Страница 2: ......

Страница 3: ...10 Wiring diagram 10 Troubleshooting 11 Exploded view 12 Spare part list 13 Maintenance log 14 Automatic oil heater REMKO AT 25 Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes or maintained incorrectly etc or if it is changed without our prior consent Subject to a...

Страница 4: ...rner with optical flame monitoring a low mainte nance axial ventilator a connection cable with plug a room thermostat socket and a fivefold filter system The unit complies with the basic safety and health re quirements of the relevant EU stipulations and is reli able and simple to operate The unit can be used e g in the following areas for drying new buildings for point heating of outdoor workplac...

Страница 5: ...nd doors or openings which are not lockable are present in the region of ceiling and floor for the air supply and for out going air and the size of these openings in m corresponds with at least 0 003 times the nominal heat output in kW of all units operating in the room 2 6 The unit must not be installed or operated in rooms and areas where the danger of fire or explosion ex ists 3 Room drying 3 1...

Страница 6: ...he units are generally to be operated in accordance with the safety rules the building code of the land con cerned and the fire protection code Avoid under or overpressure in the room where the unit is installed as this would result in combustion troubles Suction and blow out cross sections may not be re duced It is prohibited to connect conduits or hoses to the unit blow out opening Make sure tha...

Страница 7: ...It is not possible to get rid of paraffin discharge which is already present using the tank heating The requirement for this is the cleaning of the entire fuel system G The unit is to be installed only in well aerated rooms but not in living rooms or similar recreation rooms 1 Put operating switch 1 into 0 position OFF 2 Connect unit plug to a suitable mains socket 230V 1 50 Hz Connect the unit wi...

Страница 8: ...e a long service life and trouble free operation After each heating period or even earlier depending on the deployment conditions the entire unit including combustion chamber and burner head must be cleaned of soot sediments dust and dirt The oil filters must also be cleaned replaced at least once a year or depending on the degree of contamina tion of the fuel frequently G Setting and maintenance ...

Страница 9: ...ustment of air slide plate Fine adjustment of air slide plate by means of CO2 indi cator and soot pump CO2 value approx 10 13 Soot figure 0 1 by Bacharach 4 When maintenance has been carried out re assemble all parts carefully in reverse order 5 Pre set air flow plate air slide plate and the ignition electrode distance according to the approximate indi cations 4 2 3 4 8 air slide plate air flow pl...

Страница 10: ...re counter clockwise reduce the pressure The required pump pressure is determined according to the heating capacity please refer to unit type plate and to the nozzle size The pressure setting screw A is to be secured with the counter nut B after having set the pressure Fuel Pump The standard type of the pump runs in a system of 1 pipe The required fuel is sucked in through the suction line S For t...

Страница 11: ...f ignition electrodes or damaged insulation Adjust correctly resp replace it 13 Air flow plate of the burner head is misadjusted resp dirty Adjust correctly by means of CO2 indicator and soot pump CO2 10 13 and soot figure by Bacharach 0 1 14 Solenoid valve does not open Check solenoid valve resp replace if necessary A click should be heard during switching on off The safety temperature limiter ha...

Страница 12: ...12 Exploded View We reserve the right to make modifications in dimensions and construction in the interests of technical progress See fig A See fig B Fig A Fig B 74 ...

Страница 13: ...ition cable kit 1102159 40 ignition electrode 1102132 41 traction relief 1108325 No Description Ref No 42 thermostat socket 1101018 43 bridge circuit plug 1101019 44 protective socket big 1101615 45 capacitor 1102907 46 connection cable solenoid valve 1102825 47 hose connection fitting 1102109 48 fuel pump with solenoid valve 1103717 49 copper pipe 4 mm cpl 1102315 50 angle clutch 1 8 x 4 1102112 ...

Страница 14: ...ing screws Electric safety inspections Test run Maintenance Log Model Model No Setting and maintenance work is to be carried out only by authorised specialists Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature Signature Signature 6 Date 7 Date 8 Date 9 Date 10 Date Signature Signature Signature Signature Signature 11 Date 12 Date 13 Date 14 Date 15 Date Signature Signature S...

Страница 15: ......

Страница 16: ...REMKO GmbH Co KG Klima und Wärmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 ...

Отзывы: