Safety Instructions 

 

Please make sure that the relevant local building 
and fire protection codes as well as the regulations 
of the employer's liability insurance associations 
are observed when the units are used.

 

 

The units may be operated only by persons who 
have been trained in this field. 

The unit is to be installed and operated in such a 
way as to ensure that the employees are not endan-
gered by waste gases and radiation heat and that no 
fire can break out. 

The unit may only be installed and operated in 
rooms, when the air-rate fed to the unit is sufficient 
for combustion. 

Without an exhaust system, the unit may only be op-
erated in well aerated rooms. The permanent stay of 
persons in the room where the units are installed is 
prohibited. 

Appropriate prohibition signs are to be fitted at the 
entrances. 

Mobile fuel reservoirs may be installed only when the 
technical rules for combustible liquids are observed. 

The unit is to be installed only on a non-combustible 
ground. 

The unit may not be installed and operated in inflam-
mable and explosive surroundings. 

A safety zone of 1.5 m around the unit, as well as a 
minimum distance of 3 m from the unit's blower ap-
erture is to be maintained, even in the case of non 
combustible objects. 

The blower aperture of the unit may not be narrowed 
or equipped with hoses and conduits. 

The protective air suction grille is always to be kept 
free from dirt and loose objects. 

Make sure not to introduce foreign matters into the 
unit.

 

Make sure not to expose the unit to direct water jets.

 

All electric cables outside the unit are to be protected 
from damage (e.g. caused by animals, etc.). 

Make sure always to pull the mains plug out of the 
mains socket when maintenance and repairs are 
carried out. 

Description of Device 

 

The unit is fired directly with heating oil EL or diesel and 
can be operated with or without an exhaust-gas connec-
tion. It is intended for mobile and fully automatic deploy-
ment. 

A fuel container is built under the unit and it is equipped 
with automatic tank heating, a high-pressure atomizing 
oil burner with optical flame monitoring, a low mainte-
nance axial ventilator, a connection cable with plug, a 
room thermostat socket and a fivefold filter system. 

The unit complies with the basic safety and health re-
quirements of the relevant EU stipulations and is reli-
able and simple to operate. 
 

The unit can be used e.g. in the following areas: 

-   for drying new buildings;

 

-   for point heating of outdoor workplaces;

 

-   for point heating of workplaces in open, non fire-

hazard fabrication rooms and halls;

 

-   for temporary heating of closed and open areas; 

-   for de-icing of machines, vehicles and non flammable 

storage goods; 

-   for tempering frost-endangered parts. 

Working of Device

 

The automatic tank heating is activated by connecting 
the mains plug with a mains socket. 

When the unit has been switched on or when heat is re-
quired (automatic function with room thermostat) the 
supply air fan starts. The fan blows air into and along 
the combustion chamber. 

When the preliminary ventilation is over, the electro-
magnetic valve opens and supplies fuel to the nozzle. 
The fuel, sprayed under high pressure, is enriched by 
an adequate quantity of oxygen according to the heating 
capacity and ignited by an electric spark. 

Ignition is automatically terminated as soon as a perfect 
flame burns and the flames are controlled by the auto-
matic burner relay. After a few seconds hot air is blown 
out. 

In case of any troubles, or if the flame is unstable or 
tends to go out, the unit is switched off by the automatic 
burner relay. The fault indicator warning lamp of the 
automatic burner relay lights up. A restart cannot be 
made before the manual release of the automatic 
burner relay. 

When the unit has been switched off via the operating 
switch or the room thermostat, the supply air fan contin-
ues running for some time to cool down the combustion 
chamber and then it stops automatically. 

Depending on the required heat rate the function de-
scribed above is repeated automatically in the case of 
an operation with thermostat. 

G

 

On account of the construction type, a fixed-
location device installation is not permissible! 

G

 

During the unit’s operation, safety devices may 
neither be bridged nor blocked! 

G

 

For optimum unit operation, the device should not 
be operated at an ambient temperature above 25 °C. 

Содержание AT 25

Страница 1: ...REMKO powerful like a bear Edition GB M04 Operation Technology Spare Parts REMKO AT 25 Automatic oil heater ...

Страница 2: ......

Страница 3: ...10 Wiring diagram 10 Troubleshooting 11 Exploded view 12 Spare part list 13 Maintenance log 14 Automatic oil heater REMKO AT 25 Make sure to read these instructions carefully before starting using the unit Our guarantee will become void when the unit supplied by us is used and installed for inadequate purposes or maintained incorrectly etc or if it is changed without our prior consent Subject to a...

Страница 4: ...rner with optical flame monitoring a low mainte nance axial ventilator a connection cable with plug a room thermostat socket and a fivefold filter system The unit complies with the basic safety and health re quirements of the relevant EU stipulations and is reli able and simple to operate The unit can be used e g in the following areas for drying new buildings for point heating of outdoor workplac...

Страница 5: ...nd doors or openings which are not lockable are present in the region of ceiling and floor for the air supply and for out going air and the size of these openings in m corresponds with at least 0 003 times the nominal heat output in kW of all units operating in the room 2 6 The unit must not be installed or operated in rooms and areas where the danger of fire or explosion ex ists 3 Room drying 3 1...

Страница 6: ...he units are generally to be operated in accordance with the safety rules the building code of the land con cerned and the fire protection code Avoid under or overpressure in the room where the unit is installed as this would result in combustion troubles Suction and blow out cross sections may not be re duced It is prohibited to connect conduits or hoses to the unit blow out opening Make sure tha...

Страница 7: ...It is not possible to get rid of paraffin discharge which is already present using the tank heating The requirement for this is the cleaning of the entire fuel system G The unit is to be installed only in well aerated rooms but not in living rooms or similar recreation rooms 1 Put operating switch 1 into 0 position OFF 2 Connect unit plug to a suitable mains socket 230V 1 50 Hz Connect the unit wi...

Страница 8: ...e a long service life and trouble free operation After each heating period or even earlier depending on the deployment conditions the entire unit including combustion chamber and burner head must be cleaned of soot sediments dust and dirt The oil filters must also be cleaned replaced at least once a year or depending on the degree of contamina tion of the fuel frequently G Setting and maintenance ...

Страница 9: ...ustment of air slide plate Fine adjustment of air slide plate by means of CO2 indi cator and soot pump CO2 value approx 10 13 Soot figure 0 1 by Bacharach 4 When maintenance has been carried out re assemble all parts carefully in reverse order 5 Pre set air flow plate air slide plate and the ignition electrode distance according to the approximate indi cations 4 2 3 4 8 air slide plate air flow pl...

Страница 10: ...re counter clockwise reduce the pressure The required pump pressure is determined according to the heating capacity please refer to unit type plate and to the nozzle size The pressure setting screw A is to be secured with the counter nut B after having set the pressure Fuel Pump The standard type of the pump runs in a system of 1 pipe The required fuel is sucked in through the suction line S For t...

Страница 11: ...f ignition electrodes or damaged insulation Adjust correctly resp replace it 13 Air flow plate of the burner head is misadjusted resp dirty Adjust correctly by means of CO2 indicator and soot pump CO2 10 13 and soot figure by Bacharach 0 1 14 Solenoid valve does not open Check solenoid valve resp replace if necessary A click should be heard during switching on off The safety temperature limiter ha...

Страница 12: ...12 Exploded View We reserve the right to make modifications in dimensions and construction in the interests of technical progress See fig A See fig B Fig A Fig B 74 ...

Страница 13: ...ition cable kit 1102159 40 ignition electrode 1102132 41 traction relief 1108325 No Description Ref No 42 thermostat socket 1101018 43 bridge circuit plug 1101019 44 protective socket big 1101615 45 capacitor 1102907 46 connection cable solenoid valve 1102825 47 hose connection fitting 1102109 48 fuel pump with solenoid valve 1103717 49 copper pipe 4 mm cpl 1102315 50 angle clutch 1 8 x 4 1102112 ...

Страница 14: ...ing screws Electric safety inspections Test run Maintenance Log Model Model No Setting and maintenance work is to be carried out only by authorised specialists Remarks 1 Date 2 Date 3 Date 4 Date 5 Date Signature Signature Signature Signature Signature 6 Date 7 Date 8 Date 9 Date 10 Date Signature Signature Signature Signature Signature 11 Date 12 Date 13 Date 14 Date 15 Date Signature Signature S...

Страница 15: ......

Страница 16: ...REMKO GmbH Co KG Klima und Wärmetechnik D 32791 Lage Im Seelenkamp 12 D 32777 Lage PO Box 1827 Phone 49 5232 606 0 Fax 49 5232 606260 ...

Отзывы: