Starting the Heater: (Ignition)
1. Fill the tank with kerosene or other approved fuel until
needle on fuel gauge points to “F”.
2. Replace fuel cap and tighten firmly.
3. Connect the heater to a three prong (grounded) power
source. You must use a three prong (grounded)
extension cord that is at least 6 feet long and is a
minimum of 14 AWG rating.
4. Press the power button to power on the heater (see
Figure 3).
5. Select desired temperature using tempe/-
buttons.
6. The heater will ignite once the temperature setting is
higher than the ambient temperature in the space.
Stopping / Restarting Heater:
-
To stop the heater, move the power switch to the
“Off” position and unplug the power cord.
-
To restart the heater; wait 10 seconds and follow
ignition steps.
Adjusting the Pump Pressure:
-
Remove the right side cover (4 screws). Behind the
panel, the pump will have a Phillips screw. There is a
small “P” next to the pump adjustment screw. Turn
screw in quarter turn increments.
-
Clockwise increases the pressure.
-
Counterclockwise decreases pressure.
TIP: If the heater does not ignite; press power
button to power off the heater, check steps
1-3 above and press power button to power
ON the heater.
TIP: If the heater does not ignite, the thermostat
may be set too low. Increase the temperature to a
higher setting until the heater ignites.
Figure 3
SDR 220 Rating Label + Control Panel
Model - Modèle MH-220T-SDR
Minimum Distance From Combustibles:
Outlet:
8 ft.
Sides / Top / Rear:
4 ft.
Dégagement minimal des matériaux combustibles :
Sortie :
2,5 m
Côté / dessus / arrière:
1,2 m
BTU/hr / kW 220,000 / 64.5
Fuel Consumption: Gal./Hr / L/h
Consommation de carburant: Gal./Hr / L/h
Fuel Tank Capacity: Gallon / Liter
Capacité du réservoir: Gallon / Litre
V~Hz/Amps - V~Hz/Ampères 120V~60Hz / 3.15
Fuse - Fusible 3.15A
Type of Fuel No. 1 / Kerosene
Type de combustible n° 1 / Kérosène
Maximum Air Outlet Temp. °C
Temp. maximale de sortie d'air °C
Pump Pressure PSI / BAR
Pression de la pompe PSI / BAR
Phase - Phase 1Ø
1.67 / 6,3
13 / 49
552
Made In China
Fabriqué en Chine
See Operating Instructions and Troubleshooting
on side panel.
Voir les instructions de fonctionnement et de
dépannage sur le panneau latéral.
°F
°F
MASD-003
123 / 8,48
COMPLIES WITH/CONFORME AUX
NORMES UL 733 AND/ET
CAN/CSA-B140.0-03 AND/ET CSA 140.8-1967
© 2018 Pinnacle Climate Technologies, Inc.
www.masterindustrialproducts.com