NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A
FUEL SOURCE.
© 2018 Pinnacle Climate Technologies, Inc.
Cabinet Heater User's Manual
4
RISK OF FIRE! ALWAYS LOCATE HEATER ON A STABLE AND
LEVEL SURFACE!
WARNING
SPECIFICATIONS
Model #
REM-18-PCH-B
BTU
6,600 / 12,000 / 18,000
Fuel Consumption (lb./hr)
0.31 / 0.56 / 0.83
Heat Settings
3
Maximum Operating Hours
65 / 36 / 24
Required Cylinder Lbs.
20
Fuel Type
Propane
Heating Area (Ft.
2
)
165 / 300 / 450
Specifications subject to change without notice.
–
ALWAYS install the heater so that it is not
directly exposed to water spray, rain, dripping
water, or wind.
–
Use heater in accordance with all local codes
and with CSA 5.90 U.S. (5th Ed.) Infrared
Patio Heater.
–
This heater is shipped from the factory
for use with propane (LP) gas only. Do not
convert to any other gas. Installation must
conform to local codes, or in their absence,
with the standard for the Storage and
Handling of Liquefied Petroleum Gases
ANSI/NFPA 58 and the Natural Gas and
Propane Installation Code CSA B149.1.
–
Gas supply connections should be checked
by using a 50/50 soap and water solution.
Never use a flame to check for gas leaks.
–
Use only the regulator and hose assembly
provided with this heater. Inspect the
regulator/hose assembly prior to each use of
the heater. If there is excessive abrasion or
wear, or if the hose is cut, replace it with the
proper assembly shown in the parts list, prior
to using the heater.
–
This heater is not for use on finished floors.
Minimum and Maximum Inlet Pressure
Model
REM-18-PCH-B
Min.
5 PSI
Max.
Bottle Pressure
For use with
propane (LP) gas
only.
WARNING
The hose assembly
shall be pro tected
from traffic, building
material and contact with hot surfaces both
during use and while in storage.
WARNING
SAFETY INFORMATION (CONT.)