NEVER LEAVE HEATER UNATTENDED WHILE BURNING,
CONNECTED TO A POWER SOURCE, OR WHILE CONNECTED TO A
FUEL SOURCE.
© 2018 Pinnacle Climate Technologies, Inc.
Cabinet Heater User's Manual
11
Problem
Possible Cause
Solution
Burner fails to ignite
1. Air in gas line
2. Gas pressure from cylinder
too low.
3. LP cylinder valve turned off
4. Obstruction in air
passageway.
5. Dirt in pilot orifice.
6. Safety switch in cylinder
valve engaged.
7. Tipover switch engaged.
1. Keep depressing the gas control
knob for at least 30 seconds to
remove any in line.
2. Check LP cylinder pressure. Tank
may be empty.
3. Open LP cylinder valve.
4. Inspect and clean heater
housing.
5. Blow out, or clean pilot orifice.
6. Close LP cylinder valve. Wait
1 min. for switch to click off.
Reopen LP cylinder valve slowly.
7. Move heater to a level surface.
No spark created when
ignited
1. Incorrect igniter electrode
position.
2. Electrode damaged or
broken.
3. Loose or disconnected
igniter wire.
4. Broken igniter wire.
1. Properly position electrode
2. Replace the electrode.
3. Tighten or reconnect loose wire.
4. Replace igniter wire.
Heater stops running by
itself
1. Thermocouple damaged
2. Gas control valve damaged.
3. Gas leak
4. Thermocouple not in
contact with pilot flame.
5. Tip-over switch damaged,
or loose connection at tip-
switch.
6. Out of fuel.
1. Replace thermocouple.
2. Replace gas control valve.
3. Check all connections for leaks
using 50/50 solution of dish
soap and water. Repair any leaks
found.
4. Clean inside of heater housing.
5. Inspect tip-over switch and
connections. Replace if
necessary.
6. Replace LP cylinder
TROUBLESHOOTING GUIDE