background image

NEVER LEAVE HEATER UNATTENDED WHILE BURNING OR 

WHILE CONNECTED TO A POWER SOURCE

© 2015, Pinnacle Products International, Inc. 

Kerosene Forced Air Heater User’s Manual 

  1 

Fuel Tank Assembly 

70-002-0150 

70-002-0150 

70-002-0250 

70-002-0350 

70-002-0350 

 

2 Drain 

Plug 

– 

– 

70-002-0105 70-002-0105 70-002-0105 

  3 

Fuel Gauge Assembly 

70-007-0110 

70-007-0115 

70-007-0210 

70-007-0210 

70-007-0215 

  4 

Fuel Filter Assembly 

70-003-0100 

70-003-0100 

70-003-0200 

70-003-0200 

70-003-0200 

 

5 Fuel 

Cap 

70-006-0500  70-006-0500  70-006-0500 70-006-0500 70-006-0500 

  6 

Power Cord 

70-034-0100 

70-034-0205 

70-034-0205 

70-034-0205 

70-034-0205 

  7 

Power Switch 

70-038-0100 

70-038-0100 

70-038-0100 

70-038-0100 

70-038-0100 

 

8 Window 

Display 

– 

– 

70-040-0100 70-040-0100 70-040-0100 

  9 

Thermostat Control Knob 

– 

70-031-0100 

70-031-0100 

70-031-0100 

70-031-0100 

 

10 

Lower 

Shell  –  –  – – – 

  11 

Air Line 

70-035-0100 

70-035-0200 

70-035-0300 

70-035-0400 

70-035-0500 

  12 

Thermostat Limit Control 

70-019-0100 

70-019-0100 

70-019-0100 

70-019-0100 

70-019-0200 

  13 

Combustion Chamber Assembly  70-011-0100 

70-011-0200 

70-011-0300 

70-011-0400 

70-011-0500 

 

14 Photocell 

Bracket 

70-010-0101  70-010-0101  70-010-0101 70-010-0101 70-010-0101 

  15 

Fuel Line 

70-036-0100 

70-036-0200 

70-036-0300 

70-036-0400 

70-036-0500 

 

16 Photocell 

Assembly 

70-016-0100  70-016-0100  70-016-0100 70-016-0100 70-016-0100 

  17 

Burner Head Assembly 

70-014-0101 

70-014-0101 

70-014-0301 

70-014-0401 

70-014-0401 

  18 

Nozzle Kit 

70-015-0100 

70-015-0200 

70-015-0300 

70-015-0400 

70-015-0500 

  19 

Spark Plug Kit 

70-052-0100 

70-052-0100 

70-052-0200 

70-052-0200 

70-052-0200 

  20 

Motor and Pump Assembly 

70-020-0550 

70-020-0550 

70-020-0555 

70-020-0560 

70-020-0565 

 

21 Motor 

70-021-0500  70-021-0500  70-021-0510 70-021-0520 70-021-0520 

 

22 Pump 

Body 

70-020-0101  70-020-0101  70-020-0101 70-020-0101 70-020-0401 

  23 

Rotor Kit 

70-022-0100 

70-022-0100 

70-022-0100 

70-022-0100 

70-022-0200 

  24 

End Pump Cover 

70-020-0102 

70-020-0102 

70-020-0102 

70-020-0102 

70-020-0102 

 

25 Filter 

Kit 

70-054-0100  70-054-0100  70-054-0100 70-054-0100 70-054-0100 

 

26 Lint 

Filter 

70-054-0102  70-054-0102  70-054-0102 70-054-0102 70-054-0102 

 

27 Output 

Filter 

70-054-0100  70-054-0100  70-054-0100 70-054-0100 70-054-0100 

 

28 Intake 

Filter 

70-054-0101  70-054-0101  70-054-0101 70-054-0101 70-054-0101

  29 

End Filter Cover 

70-020-0103 

70-020-0103 

70-020-0103 

70-020-0103 

70-020-0103 

  30 

Plug/Pump Adjustment Kit 

70-055-0100 

70-055-0100 

70-055-0100 

70-055-0100 

70-055-0100 

  31 

Nipple 

70-014-0104 

70-014-0104 

70-014-0104 

70-014-0104 

70-014-0104 

  32 

Capacitor 

70-020-0107 

70-020-0107 

70-020-0201 

70-020-0201 

70-020-0201 

  33 

Fan Assembly 

70-024-0100 

70-024-0200 

70-024-0300 

70-024-0400 

70-024-0400 

  34 

Ignitor 

70-037-0300 

70-037-0300 

70-037-0300 

70-037-0300 

70-037-0300 

  35 

Right Side Cover 

– 

– 

– 

– 

– 

 

  36 

Left Side Cover 

70-009-0120 

70-009-0125 

70-009-0130 

70-009-0135 

70-009-0135 

  37 

Fan Guard 

70-016-0700 

70-016-0700 

70-016-0200 

70-016-0200 

70-016-0220 

  38 

Main PCB Assembly 

70-027-0100 

70-027-0200 

70-027-0300 

70-027-0300 

70-027-0300 

  39 

Fuse 

70-027-0101 

70-027-0101 

70-027-0101 

70-027-0101 

70-027-0101 

 

40 Clip 

Nut 

70-001-0105  70-001-0105  70-001-0105 70-001-0105 70-001-0105 

 

41 

Upper 

Shell  –  –  – – – 

 

 

42 Bushing 

Grommet 

70-017-0100  70-017-0100  70-017-0100 70-017-0100 70-017-0100 

  43 

Socket Cover 

70-030-0100 

70-030-0100 

70-030-0100 

70-030-0100 

70-030-0100 

  44 

Air Pressure Gauge 

70-025-0100 

70-025-0100 

70-025-0100 

70-025-0100 

70-025-0100 

  45 

Cord Bushing 

70-033-0100 

70-033-0100 

70-033-0200 

70-033-0200 

70-033-0200 

 

46 Electric 

Outlet 

70-029-0100  70-029-0100  70-029-0100 70-029-0100 70-029-0100 

  47 

Handle 

70-001-0103 

70-001-0103 

– 

– 

– 

 

 

48 Front 

Handle 

– 

– 

70-042-0100 70-042-0200 70-042-0200 

  49 

Rear Handle 

– 

– 

70-043-0105 

70-043-0205 

70-043-0205 

  50 

Wheel Support Frame 

– 

– 

70-041-0101 

70-041-0201 

70-041-0201 

 

51 Wheel 

Axle 

– 

– 

70-041-0115 70-041-0205 70-041-0205 

 

52 Wheel 

– 

– 

70-041-1400 70-041-1400 70-041-1400 

  53 

Wheel Nut 

– 

– 

70-041-0550 

70-041-0550 

70-041-0550

 

 

54 Hardware 

Kit 

70-056-0100  70-056-0100  70-056-0210 70-056-0210 70-056-0210 

  55 

Cord Wrap 

70-032-0100 

70-032-0100 

70-032-0200 

70-032-0200 

70-032-0200 

 

56 Motor 

Supporter 

70-020-0600  70-020-0600  70-020-0610 70-020-0610 70-020-0610

 Item 

 

Part Number for Models: 

 

 

 

 No. 

Description 

HH-45-KFA 

HH-75T-KFA 

HH-125T-KFA 

HH-175T-KFA 

HH-215T-KFA 

14

Parts List

Содержание HH- 45-KFA

Страница 1: ...of life Only persons who can follow and understand these instructions should operate or service this heater If you need heater info such as an operating manual labels etcetera contact Pinnacle Product...

Страница 2: ...to comply with the precautions and instructions provided with this heater can result in death serious bodily injury property loss or damage from the hazards of fire soot production explosions burns as...

Страница 3: ...y ventilated buildings or structures under construction alteration or repair Provide at least a three square foot 2 800 sq cm opening of outside air for every 100 000 Btu Hr heater rating Refer to Ven...

Страница 4: ...s subject to change without notice Hot Air Outlet Upper Shell Lower Shell Fuel Tank Fan Guard Optional Pressure Gauge Fuel Gauge Fuel Cap Side Cover Thermostat Knob PT 70T KFA only Lamp Power Cord Pow...

Страница 5: ...ng materials for future storage Missing Parts Please Call 800 641 6996 For Assistance Carry Handle Assembly 1 Align holes in the upper housing with the 2 holes in the handle as shown in Figure 3 2 Ins...

Страница 6: ...en end wrench 19 mm open end wrench Assembly Instructions Models HH 125T KFA HH 175T KFA HH 215T KFA What s In The Box 50 mm Screws 4 30 mm Screws 8 8 mm Nuts 12 Tires 2 Cord Wraps Optional Axle Nuts...

Страница 7: ...l 4 screws are secure 7 Attach rear handle with 2 long screws 50 mm and 2 nuts through the third hole from the rear of the heater on either side See Figure 6 8 Tilt the heater up gently so it is resti...

Страница 8: ...he next Kerosene deteriorates over time OLD KEROSENE WILL NOT BURN PROPERLY IN THIS HEATER NOTE Kerosene should only be stored in a blue container that is clearly marked Kerosene Never store kerosene...

Страница 9: ...ob to desired temperature setting The thermostat set range is from 40 F to 110 F 3 Move power switch to On position The power indicator light and room temperature display will illuminate and heater wi...

Страница 10: ...WITH THE UNIT HAVE A COMPETENT SERVICEMAN MAKE ANY NECESSARY ADJUSTMENT OR REPAIRS Use only original equipment parts The use of alternate or third party components can cause unsafe operating conditio...

Страница 11: ...osene Contaminated fuel could make cleaning the fuel filter necessary immediately NOTE To remove the filter from models 45 75T KFA turn filter 90 clockwise To remove the filter from models 125T 175T 2...

Страница 12: ...I HH 125T KFA 5 0 PSI HH 175T KFA 7 5 PSI HH 215T KFA 9 0 PSI Tolerance 10 NOZZLES Nozzles should be cleaned or replaced at least once per heating season Contaminated fuel could make this necessary im...

Страница 13: ...rcuit board 8 Ignitor wire not connected to spark plug 9 Defective ignitor 1 Fill tank with fresh kerosene 2 Adjust pump pressure 3 Clean replace spark plug 4 Clean replace fuel filter 5 Clean replace...

Страница 14: ...c Kerosene Forced Air Heater User s Manual 13 17 14 16 11 15 12 40 42 46 34 4 19 17 3 5 35 8 7 1 2 9 28 29 27 32 21 22 23 31 26 30 24 18 55 47 49 50 39 38 6 45 44 43 36 10 41 20 33 37 52 51 53 48 56 E...

Страница 15: ...0 70 054 0100 26 Lint Filter 70 054 0102 70 054 0102 70 054 0102 70 054 0102 70 054 0102 27 Output Filter 70 054 0100 70 054 0100 70 054 0100 70 054 0100 70 054 0100 28 Intake Filter 70 054 0101 70 05...

Страница 16: ...to be in normal operating condition or not defective the item will be returned freight collect This Limited Warranty is in lieu of all other express warranties Pinnacle Products International Inc disc...

Страница 17: ...eguir y comprender estas instrucciones pueden operar o realizar servicio a este calentador Si necesita informaci n sobre el calentador como un manual de operaci n etiquetas etc cont ctese con Pinnacle...

Страница 18: ...ucciones provistas con este calentador puede resultar en muerte lesiones serias p rdida de propiedad da os por fuego producci n de holl n explosiones quemaduras asfixia o envenenamiento por mon xido d...

Страница 19: ...cci n temporal de edificios adecuadamente ventilados o estructuras en construcci n modificaci n o reparaci n Proporcione una abertura de al menos tres pies cuadrados 2800 cm cuadrados al aire exterior...

Страница 20: ...rmica Btu Hr 45 000 70 000 125 000 175 000 215 000 Consumo de Combustible 35 G Hr 53 G Hr 95 G Hr 1 33 G Hr 1 63 G Hr Capacidad del Despotivo G 5 0 5 0 10 0 13 0 13 0 Pressi n de la Bomba psi 3 0 4 0...

Страница 21: ...arde la caja y los materiales de embalaje para almacenamiento futuro Enrolla Cable Opcional Manija 1 Tornillos 10 mm 2 Tornillos 13 mm 2 Montaje del Manija 1 Alinee los orificios en el alojamientp sup...

Страница 22: ...Instrucciones de Montaje Modelos HH 125T KFA HH 175T KFA HH 215T KFA Qu Hay en la Caja Tornillos de 50 mm 4 Tornillos de 30 mm 8 Tuercas de 8 mm 12 Ruedas 2 Faltan partes Llame al 800 641 6996 para r...

Страница 23: ...justados 7 Adjunte la manija trasera con 2 tornillos largos 50 mm y 2 tuercas a trav s del tercer orificio de la parte posterior del calentador en cada lado Vea la Figura 6 8 Incline el calentador hac...

Страница 24: ...mpo EL KEROSENO ANTIGUO O VIEJO NO QUEMAR ADECUADAMENTE EN ESTE CALENTADOR NOTA El keroseno debe almacenarse nicamente en un contenedor azul que est claramente identificado con la palabra keroseno Nun...

Страница 25: ...ratura deseada El termostato var a entre 40 F y 110 F 3 Mueva el interruptor de encendido a la posici n On La luz indicadora de energ a y la pantalla de temperatura ambiente se iluminar n y se iniciar...

Страница 26: ...UN T CNICO REPARADOR COMPETENTE REALICE LOS AJUSTES O REPARACIONES NECESARIAS Utilice nicamente piezas de repuesto aut nticas para el equipo El uso de componentes alternativos o de terceros puede caus...

Страница 27: ...extraer el filtro de los modelos HH 45 75T KFA gire el filtro 90 hacia la dere cha Para extraer el filtro de los modelos HH 125T 175T 215T KFA gire el filtro 90 hacia la izqui erda BUJ A L mpiela y re...

Страница 28: ...FA 3 0 PSI PT 75T KFA 4 0 PSI PT 125T KFA 5 0 PSI PT 175T KFA 7 5 PSI PT 215T KFA 9 0 PSI Tolerance 10 BOQUILLAS Las boquillas deben limpiarse o reemplazarse al menos una vez por cada temporada de cal...

Страница 29: ...la presi n de la bomba 3 Limpie o reemplace la buj a 4 Limpie o reemplace el filtro de combustible 5 Limpie o reemplace la boquilla 6 Enjuague el interior del tanque con keroseno fresco y limpio 7 Ins...

Страница 30: ...onal Inc Kerosene Forced Air Heater User s Manual 13 17 14 16 11 15 12 40 42 46 34 4 19 17 3 5 35 8 7 1 2 9 28 29 27 32 21 22 23 31 26 30 24 18 55 47 49 50 39 38 6 45 44 43 36 10 41 20 33 37 52 51 53...

Страница 31: ...54 0100 70 054 0100 70 054 0100 70 054 0100 70 054 0100 26 Filtro de pelusas 70 054 0102 70 054 0102 70 054 0102 70 054 0102 70 054 0102 27 Filtro de salida 70 054 0100 70 054 0100 70 054 0100 70 054...

Страница 32: ...Si Pinnacle Products International Inc determina que el art culo est en condici n normal de funcionamiento o no defectuoso el art culo ser devuelto con flete por pagar Esta Garant a limitada sustituye...

Отзывы: