3.2 Technical details
Boiler type
Selecta
combi
system
General
Boiler control
Modulating
Nominal output (80/70°C)
kW
5.1 - 16.0
5.1 - 16.0
Nominal output (50/30°C)
kW
5.6 - 16.8
5.6 - 16.8
Maximum output DHW
kW
23.89
-
Nominal input (CH) Hs
(GCV)
kW
5.8 - 18.3
5.8 - 18.3
Nominal input (CH) Hi
(NCV)
kW
5.2 - 16.5
5.2 - 16.5
Nominal input (DHW) Hs
(GCV)
kW
5.8 - 26.7
5.8 - 26.7*
Nominal input (DHW) Hi
(NCV)
kW
5.2 - 24.0
5.2 - 24.0*
Weight dry
kg
45
42
Maximum Noise level at 1 m distance
from the boiler
dB(A)
<44
<44
SEDBUK rating
A
A
Gas- and flue details
Category
II
2H3P
Min/Max Inlet pressure natural gas
mbar
17 - 30
Gas consumption (CH/DHW)
m
n
3
/h
0.6 - 1.7 / 2.5
NO
x
-emission (n = 1)
ppm
< 25
Residual fan duty (full load)
Pa
95
Mass flue rate (CH/DHW)
kg/h
26 / 39
Classification due to discharging flue
gases
C13, C33
CH- side
Water capacity
heat exc piping
l
2.6
High limit temperature °C
110
Operating flow temperature
°C
20 - 90
Operating range
bar
0.8 - 3.0
DHW - side
Maximum flow rate at 35°C
d
t
l/min
10
-
Minimum flow
l/min
< 1
-
Water capacity l
0.2
-
Inlet water pressure
bar
0.16 - 8.0
-