n
Pump command mode - POMP
The
POMP
parameter is used to select the correct command program
for the solar pump, according to the type of pump used. PSOL control
(default setting) is designed for PWM solar-controlled heating pumps,
PuLS control for conventional frequency-modulation heating pumps
and OnOF control for "ON/OFF heating pumps.
¼
See chapter:
"List of the parameters", page 49.
n
Minimum solar pump rate - PN
. The PN parameter is used to define a minimum value for the solar
pump rate at the R1 relay outlet. The lower the pump rate, the lower
its flow rate.
¼
See chapter: "List of the parameters", page 49.
n
OTHR electrical back-up option
If the S3 domestic hot water sensor on the electrical back-up is
connected, the OTHR parameter is automatically set to On. As a
result, it is impossible to modify the setting to OFF.
If the S3 domestic hot water sensor is not connected, there is no
electrical back-up. The OTHR parameter must be set manually to
OFF.
n
Nighttime back-up set point temperature - THRn
(The parameter is only displayed if OTHR is set to On)
A
Hourly nighttime range
The
THRn
temperature is the set point to be reached by the DHW
tank using its back-up at night. The nighttime period is programmed
between the start and end times
tn O
and
tn F
respectively.
n
Daytime back-up option - O td
(The parameter is only displayed if OTHR is set to On)
The
O td
option, when the parameter is set to
On
, enables use of the
back-up during the day. The
O td
option, when the parameter is set
to
Off
, prohibits use of the back-up during the day. The
RAP
parameter (forced back-up operation) always takes precedence over
the
O td
parameter and the switch setting.
Installer parameter O td
On
User setting
RAP
Auto
3-position switch
E
0
Z
Back-up at night
Activated between
tn O
and
tn F
until
THRn
Off Activated between
tn O
and
tn F
until
THRn
Back-up during the day
Activated between
td O
and
td F
until
THRd
Off Off
I
M002802-A
I
A001032-A
M002767-B
tn O
0h
12h
0h
tn F
1
200SE-2S - 300SE-2S
5. Commissioning
26/04/2016 - 7607575-05
53