200SE-2S
300SE-2S
Performance
Primary circuit
:
Back-up exchanger
Power exchanged
(1)
kW
24
24
Performance
Flow per hour (∆T = 35 °C)
(1)
litres per hour
590
590
Transfer capacity over 10 minutes (∆T = 30°C)
(2)
litres per 10 min.
150
200
Maintenance consumption (ΔT=45K)
(3)
kWh/24h
1.8
2.2
Performance N
L
0.7
1.2
(1) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 45 °C - Primary flow rate: 2 m3/h
(2) Primary temperature: 80 °C - Domestic cold water inlet: 10 °C - Domestic hot water outlet: 40 °C - Domestic hot water storage: 65 °C
(3) Satisfies the requirements of the EN 12977–1 standard
3.5.2.
Sensor characteristics
Temperature in °C -10 0
10
20
30
40
50
60
70
80
90
100
110
Resistance in Ω
(Pt1000)
961 1000 1039 1078 1117 1155 1194 1232 1271 1309 1347 1385 1423
3.5.3.
Solar regulator
n
Specifications
4
ABS box
4
Class of protection: IP 20 / EN 60529
4
Ambient temperature: 0...35°C
4
Dimensions: 144x208x43 mm
4
Display: Alphanumeric LCD display
4
Control: via 3 keys on the front panel
4
Storage temperature: -20...+70°C
4
Inputs: 3 Pt1000 temperature sensors
4
Output: 1 inverter contact electromechanical relay and 2 high
output relays
4
Max. current: 4 A - 250 V
4
Power supply: 210...240 V(AC) - 50...60 Hz
4
Consumption on standby: 0.36 W
4
Total shutdown capacity: 4 (1) A (100...240)V
4
Shutdown capacity of the electromechanical relay: 4 (1) A
(100...240)V
4
Shutdown capacity of the high output relays: 14 (3) A (100...240)V
n
Function
4
Hour run meter on the electrical back-up.
4
Hour run meter on the solar pump.
L000612-A
200SE-2S - 300SE-2S
3. Technical description
26/04/2016 - 7607575-05
17