Code
Display text Description
Adjustment range
Subme
nu
570
710
860
1000 1150 1300
CP660
Icon display
zone
Choice icon to display this
zone
0 = None
1 = All
2 = Bedroom
3 = Livingroom
4 = Study
5 = Outdoor
6 = Kitchen
7 = Basement
8 = Swimming Pool
9 = DHW Tank
10 = DHW Electri
cal Tank
11 = DHW Layered
Tank
12 = Internal Boiler
Tank
13 = Time Program
Direct
zone
0
0
0
0
0
0
CP750
MaxZone
Preheat
time
Maximum zone preheat
time
0 - 240 Min
Direct
zone
0
0
0
0
0
0
Tab.60 Navigation for installer level
Level
Menu path
Installer
> Installation Setup > CU-GH > Submenu
> Parameters, counters, signals > Parameters
(1) See the column "Submenu" in the following table for the correct navigation. The parameters are grouped in specific functionalities.
Tab.61 Factory settings at installer level
Code
Display text Description
Adjustment range
Subme
nu
570
710
860
1000 1150 1300
AP001
BL function BL input function selection 1 = Full blocking
2 = Partial blocking
3 = User reset lock
ing
4 = Backup re
lieved
5 = Generator re
lieved
6 = Gen.&Backup
relieved
7 = High, Low Tariff
8 = Photovoltaic
HP Only
9 = PV HP And
backup
10 = Smart Grid
ready
11 = Heating Cool
ing
Gas
fired ap
pliance
1
1
1
1
1
1
AP006
Min. water
pressure
Appliance will report low
water pressure below this
value
0 - 6 bar
Gas
fired ap
pliance
0.8
0.8
0.8
0.8
0.8
0.8
AP008
Release
wait time
Waiting time after closing
the release contact to start
the heat generator.
0 - 255 Sec
Gas
fired ap
pliance
0
0
0
0
0
0
AP009
Service
hours
Number of heat generator
operating hours for raising
a service notification
100 - 25500 Hours Gas
fired ap
pliance
2550
0
2550
0
2550
0
2550
0
2550
0
2550
0
8 Settings
7734324 - v.03 - 29092020
61