![RELM EPI 3101A Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/relm/epi-3101a/epi-3101a_user-manual_1436510012.webp)
Channel 0 Settings for each Channel Group include:
F a c t o r y P r o g r a m
D e s c r i p t i o n
S e t t i n g
D i s p l a y
ID or Automatic Number Identification (ANI)’
1234567
1234567
Transmit Timeout Timer
d i s a b l e d
0 sec.
Scan Delay Time
d i s a b l e d
0 . 0 s e c .
G r o u p O n e F u n c t i o n s 1 - 1 2 3 4 5
Battery Saver lnhibit 1-1 (See Note 3)
d i s a b l e d
1 - 1 2 3 4 5
Priority Scan Operation 1-2 & 3
d i s a b l e d
1 - 1 2 3 4 5
\I/
Priority Key Lockout 1-4
e n a b l e d
1 - 1 2 3 4 5
/I\\I/
Scan List Lockout 1-5
e n a b l e d
1-1
Group Two Functions 2-12345
U s e r C o d e G u a r d S e l e c t i o n 2 - 1
d i s a b l e d
2 - 1 2 3 4 5
Busy Channel Operation 2-2 & 3
d i s a b l e d
2 - 1 2 3 4 5
ID or ANI Enable 2-4
d i s a b l e d
2 - 1 2 3 4 5
D T M F E n a b l e 2 - 5
d i s a b l e d
2 - 1 2 3 4 5
NOTES:
1.
The ID Number is initially used for production purposes and the
2 .
Number shown is only an example.
Only the ID, Transmit Timeout Timer and Battery Saver Inhibit
may be changed from the Factory settings. Scan Delay Time
and all other Functions should not be changed.
3 .
It is highly recommended that the ID, Transmit Timeout Timer
and Battery Saver Inhibit settings be the same for Channel
Group 01 and Channel Group 02.
Battery Saver Inhibit should be enabled only in order to get
proper voltage readings when the Unit is being serviced, or if the
system in which the Unit is being used requires an extremely fast
squelch attack time. However, the Radio’s current drain and
battery life specifications are based upon the Battery Saver
being turned on.
\I/
4.
for example, indicates that Function (l-1) is enabled and its
corresponding number(s) in the display is flashing. When a
Function is disabled, its corresponding number(s) is steady.