THERMOJET
®
G3500E SERIES
OIL PURIFIER SYSTEM
INSTALLATION AND OPERATING MANUAL
Doc #
77740123
Rev
14
Date
June 2020
Page
48
of
104
Maintenance Checks
To insure proper system operation the following maintenance procedures should be performed according to
the schedule indicated below. If the any interim abnormal operating condition is observed on a shorter than
indicated interval, maintenance actions should be executed as those conditions are observed. If your
operating conditions are considered to be in an extremely dusty or humid environment, the maintenance
schedule should be accelerated. Consult with the nearest manufacturing office/service center for further
discussion and recommendations.
NOTICE:
Wear appropriate personal protective gear.
When cleaning oil spills consult with your
lubricating oil supplier and the lubricating oil MSDS
documentation regarding safe guards and
Personal Protective Equipment (PPE)
requirements.
The oil filter will be filled with contaminated oil.
Ensure that the container used for receiving the
drained oil and other fluids is sufficiently large to avoid
spills.
In case of oil spillage, the user or other responsible
body must ensure appropriate cleanup and
decontamination is carried out. Reference
CLEANING
AND DECONTAMINATION
in the ROUTINE
MAINTENANCE section of this manual.
The oil in the ThermoJet Oil Purifier and its
subassemblies may be contaminated with the
substances being removed from the processed oil.
Ensure that the methods used to manage and
dispose of these materials are in compliance with all
governing authorities and plant policies and
procedures.