Types of Product Misapplication and Misuse Not Covered By Warranty or Guarantees
1. Prolonged operation with air bubbles in the oil flow which causes pump cavitation and/or relief valve
chatter.
2. Excessive water ingression beyond the system capability at maximum operating temperature.
3. Operating with inadequate oil flow caused by:
A.
Suction lines too small.
B.
Elevated sections of suction piping.
C.
Suction line restrictions.
D.
Excessively high viscosity.
E.
Excessive suction lift.
4. Excessive solids contamination with no pre-filter.
5. Presence of contaminants which are not within the scope of removal for air stripping
technology, for example heavy hydrocarbons, ethylene glycol, carbon black or
attempting to
purify motor oils.
6. Presence of contaminants which attack Viton seals.
7. High differential pressure on oil filter.
8. Operating without oil filter element or inlet Y-strainer element.
9. Operating with inlet Y-strainer plugged.
10. Incoming oil temperature too cold for heater capacity (except for small reservoir volumes).
11. Operating either above or below recommended operating pressures.
12. Discharging oil into reservoir below the oil level.
13. Operating on under-voltage, over-voltage or wrong voltage.
14. Inadequate power supply, i.e. amperage rating of breaker or fuses under-sized for load required.
15. Vent line piping not extending fifteen (15) feet above the
ThermoJet
.
16. Connection to pressurized reservoir without inlet pressure reducing valve or discharge
boosting
means
NOTICE:
If this is a temporary condition, free water may be drained manually from the
reservoir while a permanent solution is implemented. If it is constant condition,
request customer service on the feasibility of installing an automatic water drain
valve.