REID LIFTING PORTABASE PBCB00001 Скачать руководство пользователя страница 9

9

PORTA

BASE

    The substrate of the structure on which the 

product is placed must be able to sustain the 
loads specified for the device in all orientations 
permitted, including a safety factor of at least 2

    Never exceed the number of allowable users

    Never adjust the product whilst a person is 

attached to it

    Only use designated anchor points for the 

attachment of fall protection devices

    Ensure that any fall protection system 

components being used are compatible and 
meet the requirements of applicable standards

    When using this product ensure that there is a 

rescue plan prior to starting work and ensure 
that users are trained in the correct execution 
of the plan and have all necessary rescue 
equipment to hand

    Where required by regulation, each installation 

must be approved by a qualified person 

    Always wear appropriate PPE when installing, 

setting up, dismantling and using this 
equipment

    Misuse of this product could result in serious 

injury or death

Warning

    For fall protection applications the maximum 

user weight is 150kg or the weight allowed by 
the lowest rated piece of equipment in the fall 
arrest system

    Ensure that you have read and understood the 

maximum force tables for each anchor point on 
the corresponding davit selected to be used 
with the Porta Base. This varies (is reduced) as 
the Davit radius increases

    When using for fall protection, only use one 

fall arrest device with each pulley/sheave and 
make sure they never cross paths with each 
other 

    When using the product in conjunction with 

another manufacturers fall protection products, 
ensure that you have read the instructions for 
use of those products to ensure their suitability 
and any restrictions for use. Only use approved 
brackets for the connection of winches and self 
retracting lifelines

    It is essential for safety that the product is 

withdrawn from use immediately and not be 
used again until confirmed in writing by a 
competent person should; 

            

 

1. Any doubt arises about its condition for 
safe use or; 

            

 

2. It has been used to arrest a fall 

            

 

3. It has been used for any other purpose, 
other than as a component of a personal 
fall protection system

IRATA [International Rope Access Trade 

Association]

This product is suitable for rope access and 
has been tested to 15kN static load as per test 
requirements of IRATA international code of 
practice (ICOP).

Содержание PORTABASE PBCB00001

Страница 1: ...REIDLIFTING COM PORTABASE Assembly Operation Guide...

Страница 2: ...eration Warning IRATA Inspection Maintenance 16 Regular Inspections Maintenance Repair Storage Transportation ATEX 18 ATEX Classification Zone 2 Spark Formation Static Electricity Inspection Maintenan...

Страница 3: ...and cleaning Maintenance inspection and repair Transportation It is the responsibility of the end user to adhere to the Health Safety and accident prevention standards and legislation valid in their r...

Страница 4: ...uct is of no relevance to fall protection standards and requirements and the user should refer to the specific sections of the instructions for use for detailed information For example EN795 requires...

Страница 5: ...ch accessory used in conjunction with the product also needs to be considered Please refer to the tables for information on capacities and required amounts of counterweight The capabilities and counte...

Страница 6: ...g should only be carried out when the load chain forms a straight and vertical line between the load and lifting attachment point Only use this product when all leveling feet have been deployed and le...

Страница 7: ...nces remove any weights from the basket during a lift Only applicable to the counterbalance system Allowable Rotation H Base The operating radius for the H Base is within the inside of the legs of the...

Страница 8: ...versions are designated with a C at the end the product number on the serial label attached to each product Additional Notes for Correct Operation Warnings Always carry out pre use checks before using...

Страница 9: ...west rated piece of equipment in the fall arrest system Ensure that you have read and understood the maximum force tables for each anchor point on the corresponding davit selected to be used with the...

Страница 10: ...T Type S Davit Radius Anchor Point A Anchor Point B Anchor Point C Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 22 2 kN 1200 mm 16 kN 16 kN 22 2 kN Fixed Socket Only 1600...

Страница 11: ...Point A Anchor Point B Anchor Point C Anchor Point D Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 16 kN 22 2 kN 1200 mm 16 kN 16 kN 16 kN 22 2 kN Fixed Socket Onl...

Страница 12: ...IT Type DW Davit Radius Anchor Point A Anchor Point B Anchor Point C Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 16 kN 1200 mm 16 kN 16 kN 16 kN Fixed Socket Only 1600 m...

Страница 13: ...uced Radius PDQRW Davit Radius Anchor Point A Anchor Point B Anchor Point C 800 mm 16 kN 16 kN 16 kN This product was developed for the PORTABASE range including H Base and Counterbalance where the re...

Страница 14: ...adius Anchor Point A Anchor Point B Anchor Point C P1 1000 mm 15 kN 15 kN 15 kN P2 1100 mm 15 kN 15 kN 15 kN P3 1200 mm 15 kN 15 kN 15 kN This product is designed for fixed sockets or with the PORTABA...

Страница 15: ...sition Davit Radius Anchor Point A Anchor Point B Anchor Point C P1 1300 mm 12 kN 12 kN 12 kN P2 1400 mm 12 kN 12 kN 12 kN P3 1500 mm 12 kN 12 kN 12 kN This product is designed for fixed sockets or wi...

Страница 16: ...Davit is fully engaged in the hub before applying a load Check the Davit in accordance with its corresponding Assembly Operation Guide Only applicable to the counterbalance system Inspections are inst...

Страница 17: ...sent of the manufacturer Any necessary repairs identified during inspections should only be carried out by an approved specialist workshop using original spare parts Any repair must be carried out in...

Страница 18: ...mists or by air and dusts mixtures are unlikely to occur or if they do occur are likely to do so only infrequently and for a short period only If the product is suitable for use in this environment it...

Страница 19: ...hat could create electrostatic charging The structure is predominantly constructed from aluminium which will not rust However there are steel components used throughout Where there is sign of any rust...

Страница 20: ...se system will be delivered in three components which are the Left Leg Assembly Right Leg Assembly and Central Hub Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructi...

Страница 21: ...ctions and secure them into position with the R clips provided Insert the Davit into the Central Hub for use NB Please refer to the Assembly Operation Guide of the applicable Davit system when used in...

Страница 22: ...ystem will be delivered in five components which are the Left Leg Assembly Right Leg Assembly Central Hub Tail and Basket Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly In...

Страница 23: ...ded Repeat steps 1 and 2 for the second Leg Assembly securing the Leg Assembly to the Central Hub Insert the first Leg Assembly into the Central Hub Remove the pins from each side to unfold the basket...

Страница 24: ...side plate between the end plate channels Ensure the side plate sits correctly over the pin Secure in place with the pins Repeat steps 7 10 for the second side plate Attach the basket to the tail and...

Страница 25: ...of the Leveling Feet Insert the Davit into the Central Hub for use NB Please refer to the Assembly Operation Guide of the applicable Davit system when used in conjunction with the PORTA BASE 25 PORTAB...

Страница 26: ...Variants Options...

Страница 27: ...e height adjustment legs fully retracted as shown in figure 2 Position the system in place for the lift before setting the height Manually raise each leg in turn and set the height by rotating the han...

Страница 28: ...Dimensions 332 450 1150 1600 1830 Max 1430 Min 115 mm Height Adjustment PORTABASE H Base...

Страница 29: ...29 PORTABASE PORTABASE Counterbalance 2720 Max 2320 Min 2415 962 1950 240 140 320 638 600 92mm Height Adjustment...

Страница 30: ...ombining quality systems management environmental issues and the health and safety practices within the company ISO 9001 2015 Quality management system which assesses an organization s ability to cons...

Страница 31: ...ght portable and safe lifting solutions Innovation category 2006 and 2013 International Trade 2013 and 2018 Testing Testing and technical file review are integral parts of our design and manufacturing...

Страница 32: ...Product labelling The following labels must be present on the product and must be legible 1 2 3 4 5 4 4 5 5 4 2 1 3 2 3 2 3 6 6 6 Product Labelling PORTABASE H Base...

Страница 33: ...Product labelling The following labels must be present on the product and must be legible 1 2 3 4 5 4 4 4 5 5 5 5 6 2 1 3 6 6 6 3 3 2 2 3 3 33 PORTABASE PORTABASE Counterbalance...

Страница 34: ...Notes...

Страница 35: ...s unique serial number The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Periodic Exami...

Страница 36: ...quiries reidlifting com www reidlifting com Printed using environment friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names a...

Отзывы: