REID LIFTING PORTABASE PBCB00001 Скачать руководство пользователя страница 8

Fall Protection Application

Fall Protection

This section must not be read in isolation from 
all other sections of this manual. Read the whole 
manual before using this product.

Fall arrest: 

This product is tested and conforms 

to the requirements of EN795:2012 Personal Fall 
Protection Equipment – Anchor Devices subject 
to the configuration of the product and the Davit 
being used. 

When being used for fall arrest purposes, the 
operator must use a body harness and a shock 
absorber that complies with the relevant national 
standards and regulations and that limits the 
maximum allowed force (m.a.f.) to 6kN. 

Each personnel lift must be properly planned, 
and all weights clearly known along with a clear 
understanding of the WLL and constraints of all 
personal fall arrest system components. 

The capabilities stated in the table below apply to 
standard range systems only. If unsure about your 
system consult serial labels, information filled in on 
page 31 or consult your supplier. Custom versions 
of the system are available tailored to specific lifting 
needs. These versions are designated with a ‘C’ 
at the end the product number on the serial label 
attached to each product. 

Additional Notes for Correct Operation 

& Warnings

    Always carry out pre-use checks before using 

this equipment. It is advised to use a buddy 
system and inspection must be by a competent 
person

    Never walk away from the footprint of the 

product or move outside designated safe 
zones whilst connected to it where there is a 
risk of a fall

    When using the product as a fall arrest anchor 

ensure there is adequate fall clearance when 
working at height. A competent person should 
calculate this, taking in to account all of the 
components of the personal fall arrest system

    Always consider the potential effects of 

sharp edges, chemical reagents, electrical 
conductivity, cutting, abrasion, climatic 
exposure on all components of the fall 
protection system, and the effect of offset 
forces as a result of pendulum falls

    Ensure the structure on which the product is 

mounted is horizontal enough to get it to be 
level (check bubble indicator) after the feet are 
adjusted

    If the product has been subjected to a fall 

arrest or impact force it must be immediately 
removed from service

Davit Radius

Counterweight Required [kg]

EN795

800mm

360kg

1000mm

360kg

1200mm

360kg

Содержание PORTABASE PBCB00001

Страница 1: ...REIDLIFTING COM PORTABASE Assembly Operation Guide...

Страница 2: ...eration Warning IRATA Inspection Maintenance 16 Regular Inspections Maintenance Repair Storage Transportation ATEX 18 ATEX Classification Zone 2 Spark Formation Static Electricity Inspection Maintenan...

Страница 3: ...and cleaning Maintenance inspection and repair Transportation It is the responsibility of the end user to adhere to the Health Safety and accident prevention standards and legislation valid in their r...

Страница 4: ...uct is of no relevance to fall protection standards and requirements and the user should refer to the specific sections of the instructions for use for detailed information For example EN795 requires...

Страница 5: ...ch accessory used in conjunction with the product also needs to be considered Please refer to the tables for information on capacities and required amounts of counterweight The capabilities and counte...

Страница 6: ...g should only be carried out when the load chain forms a straight and vertical line between the load and lifting attachment point Only use this product when all leveling feet have been deployed and le...

Страница 7: ...nces remove any weights from the basket during a lift Only applicable to the counterbalance system Allowable Rotation H Base The operating radius for the H Base is within the inside of the legs of the...

Страница 8: ...versions are designated with a C at the end the product number on the serial label attached to each product Additional Notes for Correct Operation Warnings Always carry out pre use checks before using...

Страница 9: ...west rated piece of equipment in the fall arrest system Ensure that you have read and understood the maximum force tables for each anchor point on the corresponding davit selected to be used with the...

Страница 10: ...T Type S Davit Radius Anchor Point A Anchor Point B Anchor Point C Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 22 2 kN 1200 mm 16 kN 16 kN 22 2 kN Fixed Socket Only 1600...

Страница 11: ...Point A Anchor Point B Anchor Point C Anchor Point D Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 16 kN 22 2 kN 1200 mm 16 kN 16 kN 16 kN 22 2 kN Fixed Socket Onl...

Страница 12: ...IT Type DW Davit Radius Anchor Point A Anchor Point B Anchor Point C Porta Base Fixed Socket 800 mm 22 2 kN 22 2 kN 22 2 kN 1000 mm 16 kN 16 kN 16 kN 1200 mm 16 kN 16 kN 16 kN Fixed Socket Only 1600 m...

Страница 13: ...uced Radius PDQRW Davit Radius Anchor Point A Anchor Point B Anchor Point C 800 mm 16 kN 16 kN 16 kN This product was developed for the PORTABASE range including H Base and Counterbalance where the re...

Страница 14: ...adius Anchor Point A Anchor Point B Anchor Point C P1 1000 mm 15 kN 15 kN 15 kN P2 1100 mm 15 kN 15 kN 15 kN P3 1200 mm 15 kN 15 kN 15 kN This product is designed for fixed sockets or with the PORTABA...

Страница 15: ...sition Davit Radius Anchor Point A Anchor Point B Anchor Point C P1 1300 mm 12 kN 12 kN 12 kN P2 1400 mm 12 kN 12 kN 12 kN P3 1500 mm 12 kN 12 kN 12 kN This product is designed for fixed sockets or wi...

Страница 16: ...Davit is fully engaged in the hub before applying a load Check the Davit in accordance with its corresponding Assembly Operation Guide Only applicable to the counterbalance system Inspections are inst...

Страница 17: ...sent of the manufacturer Any necessary repairs identified during inspections should only be carried out by an approved specialist workshop using original spare parts Any repair must be carried out in...

Страница 18: ...mists or by air and dusts mixtures are unlikely to occur or if they do occur are likely to do so only infrequently and for a short period only If the product is suitable for use in this environment it...

Страница 19: ...hat could create electrostatic charging The structure is predominantly constructed from aluminium which will not rust However there are steel components used throughout Where there is sign of any rust...

Страница 20: ...se system will be delivered in three components which are the Left Leg Assembly Right Leg Assembly and Central Hub Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly Instructi...

Страница 21: ...ctions and secure them into position with the R clips provided Insert the Davit into the Central Hub for use NB Please refer to the Assembly Operation Guide of the applicable Davit system when used in...

Страница 22: ...ystem will be delivered in five components which are the Left Leg Assembly Right Leg Assembly Central Hub Tail and Basket Appropriate PPE should be worn Gloves Protective Footwear Hard Hat Assembly In...

Страница 23: ...ded Repeat steps 1 and 2 for the second Leg Assembly securing the Leg Assembly to the Central Hub Insert the first Leg Assembly into the Central Hub Remove the pins from each side to unfold the basket...

Страница 24: ...side plate between the end plate channels Ensure the side plate sits correctly over the pin Secure in place with the pins Repeat steps 7 10 for the second side plate Attach the basket to the tail and...

Страница 25: ...of the Leveling Feet Insert the Davit into the Central Hub for use NB Please refer to the Assembly Operation Guide of the applicable Davit system when used in conjunction with the PORTA BASE 25 PORTAB...

Страница 26: ...Variants Options...

Страница 27: ...e height adjustment legs fully retracted as shown in figure 2 Position the system in place for the lift before setting the height Manually raise each leg in turn and set the height by rotating the han...

Страница 28: ...Dimensions 332 450 1150 1600 1830 Max 1430 Min 115 mm Height Adjustment PORTABASE H Base...

Страница 29: ...29 PORTABASE PORTABASE Counterbalance 2720 Max 2320 Min 2415 962 1950 240 140 320 638 600 92mm Height Adjustment...

Страница 30: ...ombining quality systems management environmental issues and the health and safety practices within the company ISO 9001 2015 Quality management system which assesses an organization s ability to cons...

Страница 31: ...ght portable and safe lifting solutions Innovation category 2006 and 2013 International Trade 2013 and 2018 Testing Testing and technical file review are integral parts of our design and manufacturing...

Страница 32: ...Product labelling The following labels must be present on the product and must be legible 1 2 3 4 5 4 4 5 5 4 2 1 3 2 3 2 3 6 6 6 Product Labelling PORTABASE H Base...

Страница 33: ...Product labelling The following labels must be present on the product and must be legible 1 2 3 4 5 4 4 4 5 5 5 5 6 2 1 3 6 6 6 3 3 2 2 3 3 33 PORTABASE PORTABASE Counterbalance...

Страница 34: ...Notes...

Страница 35: ...s unique serial number The goods capacity WLL of the device The year of manufacture The standards to which the device is approved The ATEX rating of the product if applicable CE Marking Periodic Exami...

Страница 36: ...quiries reidlifting com www reidlifting com Printed using environment friendly processes and materials All information herein is copyright protected by REID Lifting Ltd All company and product names a...

Отзывы: