19
PORTA
BASE
Static Electricity
For Zone 2 applications, there is a potential risk of
static electricity build-up leading to an incentive
spark. To mitigate the risk powder coated sections
will be removed to ensure the product has a clear
route to earth. Although the risk of such ignition is
unlikely, it is the user’s responsibility to ensure that
the route to earth is maintained.
Inspection, Maintenance & Repair
Special attention should be given to dust deposits
on the structure, especially in areas where the
profiles come into contact, and should be wiped
clean and care taken not to apply materials that
could create electrostatic charging.
The structure is predominantly constructed from
aluminium which will not rust. However, there are
steel components used throughout.
Where there is sign of any rust deposits on the
aluminium structure, it should be wiped clean as
above and, where there is sign of rust on a steel
component, that component should be removed
from use and the structure not used until a
replacement is fitted.
If using this product in explosive atmospheres,
in addition to the Regular Inspection and
Maintenance information above, these additional
instructions should be followed:
Inspections must be instigated by the user prior
to each use if used in a potentially explosive
atmosphere.
Inspections and maintenance must be carried
out at a safe distance away from an explosive
atmosphere.