3 HMI
Controls
Functions
1
2
3
4
5
6
7
8
9
11
12
10
13
1
Operation
Boot 1.)
2.)
Inication of arc voltage
Indication of software version e.g. P2.4
Indication of product version e.g. 404
2
Operation
Boot 1.)
2.)
Indication of welding current or material thickness
Version of welding characteristic e.g.1.2
„on“ shows power source ready
3
Control LED „
Operation
“ (
grün
)
Standby voltage is connected to the torch.
Arc ingnition will be activated if wire touches material.
4
Control LED „
Temperature
“ (
gelb
)
If temperature gets too high the machine switches off the power to
protect internal power components. Cooling stays active.
If temperature comes under a certain level, machine is reactivated
and LED switched off.
5
Control LED „7-Segment indicates material thickness“ (
grün
)
If switch (position 7) is placed on the symbol
the HMI on
7-segment indicator 2 shows material thickness. The value is related
to the machine adjustments you did. In that mode no welding is
possible.