EARLY START  

Heating - The early start function for heating ensures that the 
zone is up to the proper temperature at the beginning of each 
period. The

 

thermostat learns the recovery rate over multiple 

setback events in order to determine the proper lead-time for the 
zone. If both an air sensor and a slab sensor are used, the lead-
time is the greater of the air sensors or the slab sensor’s 
requirements. 
 
Cooling 
- The early start function, when used with cooling, allows the cooling system to turn on 30 minutes 
prior to the beginning of a period that requires cooling. 
 
Note: 
The Early Start feature occurs when the schedule changes 
from a low temperature to a higher temperature. 

 
AUXILIARY SENSORS 

The thermostat has a single built-in sensor to measure air temperature at the thermostat. In addition to the 
built-in sensor, the thermostat has terminals to connect one separate sensor. This sensor can be either 
indoor sensors, slab sensors, a remote sensor, or an outdoor sensor.

 

 

Indoor Sensor 

An indoor sensor is used to measure the air temperature in the zone that the thermostat is 
controlling. The temperature being read by the indoor sensor is used in the calculations of the on 
times for the relay(s) in the thermostat. If more than one sensor, either the built-in sensor or an 
auxiliary sensor set as an indoor sensor, is being used to measure the zone temperature, the 
temperature of the active sensors is averaged and used to calculate the on time of the relay(s). 
 

Slab Sensor 

A slab sensor is used to measure the slab temperature in the zone that the thermostat is 
controlling. The temperature being read by the slab sensor is used in the calculations of the on time 
for the Heat relay and allows the thermostat to operate the slab between the slab minimum and 
slab maximum settings. If more than one slab sensor is used, the slab temperatures are averaged 
by the thermostat.

 

 
Remote Sensor 

A single remote sensor can be connected to the thermostat. The temperature measured by a 
remote sensor does not affect the on time of the relays and is only used for display purposes.  

 

 
Outdoor Sensor
 

A single outdoor sensor can be connected to the thermostat. The temperature measured by an 
outdoor sensor does not affect the on time of the relays and is only used for display purposes.

 

 
ACCESS LEVELS
 

The REHAU Programmable Thermostat has two access levels. These 
access levels restrict the number of items available in the menus of the 
thermostat. The two access levels are Installer and User. This selection is 
made using the DIP switch located on the circuit board inside the 
thermostat.

 

 

 

1-OFF 
2-OFF 

The Installer access level allows the installer to adjust all of the setting in 
the thermostat including those required to match the thermostat to the 
mechanical system and the devices used.  A “lock” icon is displayed in 
lower right. 
 

1-ON 
2-ON 

The User access level allows the end user to adjust the time, temperatures and schedules used by the 
thermostat.  A “lock” icon is displayed in lower right while in the MENU mode. 

Содержание 236457

Страница 1: ...ne Stage Heat Art 236457 Control Microprocessor PI control This is not a safety limit control Packaged weight 0 46 lb 210 g Enclosure J white PVC plastic Dimensions 2 7 8 H x 2 7 8 W x 13 16 D 73 x 73...

Страница 2: ...cycles and accumulating a knowledge of just how the heating system is working This allows the thermostat to anticipate the system and prevent a system short cycling In order to prevent short cycling...

Страница 3: ...is being used to measure the zone temperature the temperature of the active sensors is averaged and used to calculate the on time of the relay s Slab Sensor A slab sensor is used to measure the slab...

Страница 4: ...e Off mode a freeze protection is enabled that allows the Heat relay to be operated to keep the zone above 35 F 2 C PD2 Two Stage Heat The two stage mode of operation is selected using the DIP switch...

Страница 5: ...e above 35 F 2 C PD2 Heat Cool The Heat Cool mode of operation is selected using the DIP switch located on the circuit board inside the thermostat Air Sensor s Only Operation When operating with only...

Страница 6: ...no interlock between the heating and cooling temperature Installation STEP ONE GETTING READY Check the contents of this package If any of the contents are missing or damaged please contact your wholes...

Страница 7: ...thermostat Auxiliary Sensors S1 and S2 Either an indoor slab or remote sensor may be connected to the S1 input Connect the two wires from the auxiliary sensor to the Com and S1 terminals 3 and 4 Heat...

Страница 8: ...current air temperature for the space If the optional sensor is not used for the floor slab but for the room this is the average temperature Outdoor The current temperature at the outdoor sensor Sens...

Страница 9: ...an active air sensor and be set to either Heat or Auto 35 to 100 F 1 5 to 38 0 C Room Cool No Schedule Desired temperature for cooling Must have an active air sensor and be set to either Cool or Auto...

Страница 10: ...or Auto 35 to 100 F 1 5 to 38 0 C Room Heat Sleep Desired temperature for Sleep time Must have an active air sensor and be set to either Heat or Auto 35 to 100 F 1 5 to 38 0 C Room Cool Wake Desired r...

Страница 11: ...eep time Must have an active air sensor and be set to either Cool or Auto 35 to 100 F 1 5 to 38 0 C Slab Minimum Wake Minimum slab temperature at wake time Must have an active slab sensor OFF 34 to 12...

Страница 12: ...lects the type of auxiliary sensor present in the Sen 1 input This item is only available in the Installer access level OFF Indr thermostat averages in this case SLAB OUTside Room Sensor Selects wheth...

Страница 13: ...evel 10 to 180 min Cooling Minimum On Sets the minimum on time of the cooling contact This is to prevent short cycling This item is only available in the Installer access level 0 30 to 5 00 min Coolin...

Страница 14: ...Page 14 of 19 Adjust Menu 6 of 6 Lite Sets the operation of the back lighting of the LCD ON Tmpy ON OFF Units The units of temperature used to display the items F C...

Страница 15: ...he fault is corrected press any button to clear the error message Room Short The thermostat s internal air sensor is short circuit This cannot be repaired in the field The thermostat should be replace...

Страница 16: ...Sensor 1 Open The auxiliary sensor connected to the Sens 1 terminal is open circuit Locate and repair the problem as described in the appropriate sensor brochure After the fault is corrected press an...

Страница 17: ...aller Us Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2A No Power 158033 PD1 C US Zone Pump 24V ac Class II Transformer Wiring to Powered 24 V ac Relay T Typical 1 T 2 N L Powered Relay 5 6 R C Com S1 ON 1...

Страница 18: ...taller Us Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2A No Power 158033 PD2 C US 5 6 7 8 24V ac Class II Transformer Cooling One Stage Heat with Zone Pump and Cooling Zone Pump T Typical 1 T 2 N L Powered...

Страница 19: ...taller Us Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2A No Power 158033 PD2 C US R C Com S1 ON 1 Heat2 Cool Heat 2 1 2 3 4 PD 2 236467 Heat Cool or 2 Stage Heat Installer Us Power 24 V 10 60 Hz 3 VA Relay...

Отзывы: