Error Messages

 

(1 of 2)

 

 

E01 The thermostat was unable to read a piece of information stored 
in its memory. The thermostat was required to load the factory 
settings. The thermostat will stop operation until all settings are 
checked. To clear this error, select the Installer access level and check 
all of the settings in the Adjust and Schedule menus. 
 
 
 
 
 
E02 There are no active sensors selected on the thermostat. Either the 
internal sensor must be turned on or at least one auxiliary sensor must 
be set to either INDR or SLAB. After the fault is corrected, press any 
button to clear the error message. 
 
 
 
 
 
 
Room Short  
The thermostat’s internal air sensor is short circuit. This cannot be 
repaired in the field. The thermostat should be replaced or returned for 
repair.  
 
 
 
 
 
 
Room Open  
The thermostat’s internal air sensor is open circuit. This cannot be 
repaired in the field. Either turn off the internal sensor and use an 
auxiliary sensor set to INDR or replace the thermostat.  After the fault 
is corrected, press any button to clear the error message. 
 
 

 
Sensor 1 Short 

The auxiliary sensor connected to the Sens 1 terminal is short circuit. 
Locate and repair the problem as described in the appropriate sensor 
brochure. After the fault is corrected, press any button to clear the error 
message. 
 

Содержание 236457

Страница 1: ...ne Stage Heat Art 236457 Control Microprocessor PI control This is not a safety limit control Packaged weight 0 46 lb 210 g Enclosure J white PVC plastic Dimensions 2 7 8 H x 2 7 8 W x 13 16 D 73 x 73...

Страница 2: ...cycles and accumulating a knowledge of just how the heating system is working This allows the thermostat to anticipate the system and prevent a system short cycling In order to prevent short cycling...

Страница 3: ...is being used to measure the zone temperature the temperature of the active sensors is averaged and used to calculate the on time of the relay s Slab Sensor A slab sensor is used to measure the slab...

Страница 4: ...e Off mode a freeze protection is enabled that allows the Heat relay to be operated to keep the zone above 35 F 2 C PD2 Two Stage Heat The two stage mode of operation is selected using the DIP switch...

Страница 5: ...e above 35 F 2 C PD2 Heat Cool The Heat Cool mode of operation is selected using the DIP switch located on the circuit board inside the thermostat Air Sensor s Only Operation When operating with only...

Страница 6: ...no interlock between the heating and cooling temperature Installation STEP ONE GETTING READY Check the contents of this package If any of the contents are missing or damaged please contact your wholes...

Страница 7: ...thermostat Auxiliary Sensors S1 and S2 Either an indoor slab or remote sensor may be connected to the S1 input Connect the two wires from the auxiliary sensor to the Com and S1 terminals 3 and 4 Heat...

Страница 8: ...current air temperature for the space If the optional sensor is not used for the floor slab but for the room this is the average temperature Outdoor The current temperature at the outdoor sensor Sens...

Страница 9: ...an active air sensor and be set to either Heat or Auto 35 to 100 F 1 5 to 38 0 C Room Cool No Schedule Desired temperature for cooling Must have an active air sensor and be set to either Cool or Auto...

Страница 10: ...or Auto 35 to 100 F 1 5 to 38 0 C Room Heat Sleep Desired temperature for Sleep time Must have an active air sensor and be set to either Heat or Auto 35 to 100 F 1 5 to 38 0 C Room Cool Wake Desired r...

Страница 11: ...eep time Must have an active air sensor and be set to either Cool or Auto 35 to 100 F 1 5 to 38 0 C Slab Minimum Wake Minimum slab temperature at wake time Must have an active slab sensor OFF 34 to 12...

Страница 12: ...lects the type of auxiliary sensor present in the Sen 1 input This item is only available in the Installer access level OFF Indr thermostat averages in this case SLAB OUTside Room Sensor Selects wheth...

Страница 13: ...evel 10 to 180 min Cooling Minimum On Sets the minimum on time of the cooling contact This is to prevent short cycling This item is only available in the Installer access level 0 30 to 5 00 min Coolin...

Страница 14: ...Page 14 of 19 Adjust Menu 6 of 6 Lite Sets the operation of the back lighting of the LCD ON Tmpy ON OFF Units The units of temperature used to display the items F C...

Страница 15: ...he fault is corrected press any button to clear the error message Room Short The thermostat s internal air sensor is short circuit This cannot be repaired in the field The thermostat should be replace...

Страница 16: ...Sensor 1 Open The auxiliary sensor connected to the Sens 1 terminal is open circuit Locate and repair the problem as described in the appropriate sensor brochure After the fault is corrected press an...

Страница 17: ...aller Us Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2A No Power 158033 PD1 C US Zone Pump 24V ac Class II Transformer Wiring to Powered 24 V ac Relay T Typical 1 T 2 N L Powered Relay 5 6 R C Com S1 ON 1...

Страница 18: ...taller Us Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2A No Power 158033 PD2 C US 5 6 7 8 24V ac Class II Transformer Cooling One Stage Heat with Zone Pump and Cooling Zone Pump T Typical 1 T 2 N L Powered...

Страница 19: ...taller Us Power 24 V 10 60 Hz 3 VA Relay 24 V ac 2A No Power 158033 PD2 C US R C Com S1 ON 1 Heat2 Cool Heat 2 1 2 3 4 PD 2 236467 Heat Cool or 2 Stage Heat Installer Us Power 24 V 10 60 Hz 3 VA Relay...

Отзывы: