![Rehau 236457 Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/rehau/236457/236457_instructions-manual_1434863012.webp)
Page 12 of 19
Adjust Menu
(4 of 6)
Slab Minimum Sleep
Minimum slab temperature during Sleep time.
(Must have an active slab sensor.)
OFF, 34 to 122°F (OFF, 1.0 to 50.0°C)
Slab Maximum
Maximum slab temperature. This item is only available in the installer access
level. (Must have an active slab sensor.)
34 to 122°F, OFF (1.0 to 50.0°C, OFF)
Sensor 1
Selects the type of auxiliary sensor present in the Sen 1 input. This item is
only available in the Installer access level.
OFF, Indr (thermostat averages in this case), SLAB, OUTside
Room Sensor
Selects whether the built-in sensor is functional or not. This item is only
available in the Installer access level.
OFF, ON
Heating Cycle
Determines the number of cycles per hour for the heating equipment. This
item is only available in the Installer access level. This adjustment would be
to influence “short cycling” of the heating system. Auto, 2 to 12