The desired temperatures from an auxiliary heat source should be set lower than the desired
temperatures from the heat pump to avoid unnecessary switching of the DHW-E source.
The time program setting is identical to the time program setting in zones 1 - 6.
4.4.3. Settings of DHW recirculation
DHW recirculation can be switched on or off by the
ON/OFF
button.
Interval setting
Circulation period
...... Setting the circulation pump running time (pump running)
Recirculation delay
... Setting the circulation pump idling time (pump stopped).
The time program setting is identical to the time program setting in zones 1 - 6.
USE TIME PROGRAM OF DHW ZONE
.................................... For starting the circulation pump, a time program is set identical to the
time program for DHW heating by the heat pump.
The circulation pump starts following the set intervals (circulation time and idle time) only in
comfort mode according to the time program.
Immediate recirculation
After this function is activated, the circulation pump switches on immediately and then runs for
the set time. After this time, the function switches back to automatic mode according to the
time program.
4.5.
Sources menu (SOURCES)
In the Source menu it is possible to display parameters and adjust some settings of all system
sources (heat pump, switched and modulated sources, solar thermal system, solid fuel boiler).