![REGULA 7517A Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/regula/7517a/7517a_user-manual_1434377013.webp)
13
1.2.2
State indicators of the MOV USB device:
— “device is passive” (special software is not operating with the device),
— “device is active” (special software is operating with the device),
— “MT in the bunker” (insertion or extraction of MT),
— “MT in the tract” (stitching is in process).
Algorithm of MOV USB device operation
z
Switching the PC on, loading the OS, initializing software. Automatic check-up of
the state / pre-installation of OMB equipment.
z
MT is manually inserted into the OMB buffer. Then MT is captured by the magnetic tape
drive and moved to MOV working zone.
z
Step-by-step movement of MT is followed by panoramic stitching of MOV images.
z
The quality of stitching and its informative value is controlled.
z
MT extraction: direct or reverse rotation depending on the length of the inserted MT
strip. Manual extraction of MT from the OMB buffer. The device switches to a stand-by
mode.
z
The equipment automatically switches to a stand-by mode when the “Stop” mode lasts
longer than ≈ 5 minutes. The stand-by mode is switched off as soon as a new command
is received.
Magnetic Copying Accessories Set (MCAS)
Functions
z
Creating a physical copy (recording information to intermediate flexible magnetic carrier —
magnetic tape) of magnetic stray fields distribution over the object surface. The copy reflects
relief and structural inhomogeneity of the material. Permanent magnets of the combination
magnetic scanner (CMS) concentrators serve as sources of magnetic stray fields excitation.
z
Demagnetizing magnetic tapes for further use.
z
Arranging, marking, storing and carrying the operating reserve of MT and recorded
magnetic copies.
z
Service functions while performing magnetic copying.
Technical Specifications
Dimensions of physical
copies:
length
unlimited. Recommended length — 250 mm
width
11 mm (CMS flat concentrator and compact magnetic scanner)
width
15 mm (CMS rotary concentrator)
width
21 mm (CMS rotary concentrator)
MT cartridge capacity
not more than 10 strips (250 mm long)
MCAS case dimensions
120×80×40 mm
Weight of the loaded MCAS case
0,4 kg
CMS dimensions
105×30×30 mm
CMS weight
not more than 0,2 kg
Design
The MCAS case is designed as a leather waist carrier pouch intended for carrying accessories
for magnetic copying.
The combination magnetic scanner-
demagnetizer
(CMS)
is intended for magnetization
of an examined object and magnetic biasing of magnetic tape while performing a magnetogram.
It is also used for demagnetizing magnetic copies for their further reuse. The CMS is equipped
with three replaceable concentrators on permanent magnets for use on different surfaces of
objects with various properties:
z
flat concentrator (effective width of 11 mm),
z
rotary concentrator № 1 (effective width of 15 mm),
z
rotary concentrator № 2 (effective width of 21 mm).
Содержание 7517A