![REGLOPLAS 150smart Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/regloplas/150smart/150smart_operating-instructions-manual_1434338013.webp)
V
11/2014
Temperature Control Unit 90smart/150smart
Operating Instructions
9
Powering Up
After carrying out the checks on the consumer, connecting the hoses and
electrical connections, proceed as follows:
Open the vent valve on the consumer, and also the shut-off valve
(if fitted)
Switch on the control unit/pump with the I/O switch
The operating mode switch on the front panel must be at position
+
(normal mode). After switching on, a function test runs in the
RT34 controller for about 5 seconds. All displays flash during the
test. After successful conclusion of the test, the actual value ap-
pears in the upper display field and the set-point value in the
lower display field
The water is now automatically refilled. This process can take 2-4
minutes depending on the water mains pressure. An alarm rings
during this time. The control unit can also be filled manually via
the filling opening on the filler cap
Check direction of rotation of the pump following the arrows on
the fan shroud (remove side panels). If the direction of rotation is
incorrect, two phases must be reversed on the unit plug
NOTE
Important - The operating mode switch must be at po, i.e. pressure
mode!
Check the temperature control circuit (control unit, connecting
lines, consumers, etc.) for leaks
Do not close the vent valve on the consumer until water is flow-
ing out of the consumer at a regular rate
Operating mode switch
Pressure mode
Normal mode - The heat carrier is pumped through the consumer by
pressure (switch position
+
)
Leak stop mode
The heat carrier is drawn by the consumer (reduced pump capacity,
switch position
-
)
Suction
The heat carrier is drained out of the consumer by suction, switch posi-
tion
A
. Cool down device and switch off, turn switch to position
-
and
switch device on again. Turn switch to position
A
and hold down until fully
drained (observe maximum expansion volume!)
Содержание 150smart
Страница 1: ...En 90smart 150smart Operating Instructions...
Страница 26: ...V 11 2014 22 Operating Instructions Temperature Control Unit 90smart 150smart...
Страница 37: ...V 11 2014 Temperature Control Unit 90smart 150smart Maintenance 33 Y2 Y13 69 41 68 T5 V21 F5 M10 Y6 Y13 S3 B1...
Страница 41: ...V 11 2014 Temperature Control Unit 90smart 150smart Maintenance 37...