Step 1: Move slide switch on bottom of the sensor to TEST. There are three sensitivity

settings: L (low), M (medium) and H (high). Low will be the least sensitive and
high will be the most sensitive. Approximate detection ranges are as follows:

L . . . . . . 30 feet (short range)
M  . . . . . 40-50 feet (mid-range)
H. . . . . . 60 or more feet (maximum range)

NOTE: Temperature can affect the sensitivity of the motion sensor.

It may be necessary to readjust the sensitivity when there are
major temperature changes. Set sensitivity slide switch to
medium or “M”. See diagram (O).

Step 2: Turn on the power to fixture. Allow fixture to warm up approx-

imately two minutes before testing. (Lights may or may not
come on during warm-up period.This is normal.)

Step 3: Aim sensor head in desired position. NOTE: Maintain air

spacing between lamps and sensor head at least 1”. Make
sure sensor head is positioned with control switches facing
towards the ground.

Step 4: Walk across the detection zone at the farthest distance you 

wish your detector to detect motion.

Step 5: Adjust sensitivity until you get desired results. For more range, aim sensor head

slightly upwards. For less range, aim sensor head slightly downward. Lights will
turn off four seconds after all motion stops.

Step 6: Move slide switch to four MIN (AUTO mode) or to one of the two NIGHT TIME ON

settings. At dusk, lights will operate in the AUTO or NIGHT TIME ON settings.
(Refer to page 6 for detailed descriptions of the different modes.)

The sensor and indoor alarm/lamp module must be set to the same house code number
for the system to work properly. When the outside motion sensor is activated, the indoor
alarm will sound (in 1, 2, 3, or 4 chirp intervals depending on the house code selected).
If there is a lamp plugged into the module, the lamp will come on and stay on for 10 min-
utes. More than one sensor can be used to activate an indoor alarm/lamp control mod-
ule. All outdoor sensors set to the same house code will activate ALL indoor alarm/lamp
modules that are set to the same house code number.

Indoor alarm/lamp control module operation guide (P)

House code selections on sensor head (O)

How to operate your fixture

1

2

3

4

TEST

AUTO

2 HR

4 HR

SENSITIVITY

H
M

L

Switch setting:

Tones:

Indoor lamp:

AUTO

Number of beeps based 

on house code setting 

(fixture house code must 

be same as module 

house code)

Daytime:Off 

Nighttime: On for 

10 minutes

LAMP ON

Number of beeps based 

on house code setting 

(fixture house code must 

be same as module 

house code)

On

TEST

Number of beeps based on

house code setting of the

fixture (fixture house code

does not have to be same

as module house code)

When Mode of Operation switch is

moved, lamp stays on 10 minutes .

Lamp will turn on for 10 minutes

at night if motion is detected. If fix-
ture detects motion at Night or Day

alarm will chime.

OFF

Off (No tones)

Off (No light)

O

MS249R_MS249RW 325-1486.qxd  6/20/06  4:02 PM  Page 4

Содержание CMS249R

Страница 1: ......

Страница 2: ...gaskets C Light covers D 2 8 screws E 2 6 screws F 3 Wire nuts G Mounting bracket H Center bolt I Color matched center hole plug J Indoor alarm module K WhWhat to know For outdoor use only fixture fo...

Страница 3: ...e away from heat producing sources to prevent false triggering Also be careful not to include objects such as heat pumps air conditioners laundry vents white walls and water in the detection zone when...

Страница 4: ...At dusk lights will operate in the AUTO or NIGHT TIME ON settings Refer to page 6 for detailed descriptions of the different modes The sensor and indoor alarm lamp module must be set to the same hous...

Страница 5: ...mp module module will sound a distinctive warning tone sequence A volume control HIGH MEDIUM LOW OFF is located on the side of the module to set the desired sound level If you desire the lamp to come...

Страница 6: ...the next dawn The light will operate in the first NIGHT TIMEON mode selected 2 hour or 4 hour even if changed Keep the power to the fixture on 4 Hour NIGHT TIME ON then Motion Activated Lights should...

Страница 7: ...ing in the detection zone is triggering the sensor If this is the case reduce the sensitivity Reposition motion sensor If the lights stay on with sensor lens covered contact customer service Is the un...

Страница 8: ...w to select your desired feature If lights do not come on at all in NIGHT TIME ONmode Is the surrounding external ambient light too bright If so the unit may think it s daytime Re aim the head Relocat...

Страница 9: ...implied warranty lasts so the above exclusions or limitations may not apply to you No other warranty written or verbal is authorized by the Company This warranty gives you specific legal rights and yo...

Страница 10: ...impermeable L se incluye Detector de movimiento y portal mparas A Junta obturadora de la placa de la cubierta B 2 Junta obturadora del recept culo C Cubiertas de las luces D 2 Tornillos No 8 E 2 Torni...

Страница 11: ...a empalmes de alimentaci n utilize un cableado de temperatura nominal de al menos 75 grados C Para funcionamiento correcto y protecci n contra da os los conmutadores de control del cabezal detector de...

Страница 12: ...es o m s alcance m ximo NOTA La temperatura puede afectar la sensibilidad del detector de movimiento Es posible que sea necesario reajustar la sensibilidad cuando se producen cambios grandes de tem pe...

Страница 13: ...ece encendida por 10 minutos Si se detecta movimiento por la noche la l mpara se encen der por 10 minutos Si el artefacto detecta movimiento ya sea de noche o de d a la alarma sonar OFF Apagado Apagad...

Страница 14: ...vimiento Si el sensor exterior esta en la posicion AUTO la l mpara no se encendera mas que en la noche en la posicion AUTO la l mpara exteri or se enciende siempre cuando la l mpara exterior se encien...

Страница 15: ...deben apagarse despu s de un intervalo de 8 minutos sin movimiento NIGHTTIMEON Encendido de noche 4 HR 4 Horas NOTA Una vez que la luz se enciendeen el modo de NIGHT TIME ON seleccionado no se puede...

Страница 16: ...sensor cubierta p ngase en contacto con el servicio de asistencia al cliente Est el farol en el Modo AUTO Aseg rese de que no est en uno de los dos Modos de NIGHTTIME ON LAS LUCES SE ENCIENDEN DURANTE...

Страница 17: ...unidad actuar como si fuera de d a Redirija el cabezal Cambie la ubicaci n de la unidad o dir jala en direcci n contraria a la luz LA ALARMA INTERIOR NO SUENA Est el volumen del m dulo interior ajusta...

Страница 18: ...RANTIA EXPRESA En algunos estados no se permite la exclusi n o limitaci n de da os incidentales o conse cuenciales o limitaciones sobre la duraci n de la garant a impl cita de manera que las exclusion...

Страница 19: ...ande manuelle Ce Tournevis phillips 2 Ampoules de projecteur PAR 38 de 150 watts maximum Produit de calfatage r sistant aux intemp ries Ce qui est co D tecteur de mouvement et pi ce fixe du projecteur...

Страница 20: ...alifi Le syst me lectrique de la maison et la m thode du branchement de cette pi ce fixe cette instal lation lectrique doivent respecter les sp cifications du Code lectrique national ainsi que les r g...

Страница 21: ...respondantes sont approximativement de L 9 m courte port e M 12 15 m port e moyenne H 18 m ou plus port e maximale REMARQUE La temp rature peut affecter la sensibilit du d tecteur de mouvement Il peut...

Страница 22: ...i vous n tes pas satisfait par la performance en utilisant un codage donn pour la maison passez le module sur une sortie diff rente N oubliez pas que le capteur et le module doivent tre tout moment su...

Страница 23: ...allumera que le soir en mode AUTO la lampe int rieure s allume lorsque l clairage ext rieur s allume La lampe int rieure demeurera allum e durant 10 minutes apr s que tout mou vement ait cess l ext ri...

Страница 24: ...e dispositif sous tension R glage du Soir au Matin Mode Prioritaire activ uniquement la nuit Les clairages doivent rester allum s du cr puscule l aurore puis se restaurer d s l aurore en mode de fonct...

Страница 25: ...ffecte le d tecteur de mouvement Viser les lampes nouveau Positionner nouveau le d tecteur de mouvement LES LUMI RES SONT ALLUMEES AU JOUR Est ce que l interrupteur qui se trouve au bas du d tecteur d...

Страница 26: ...l conque travail de r paration ou de remplacement puisse tre ex cut suivant les condi tions de la garantie Cette garantie ne couvre que les d faillances du produit dues des d fauts de mat riau ou de f...

Страница 27: ...n pour produits retourn s mis par la Soci t sera refus Cooper Lighting n est pas responsable des marchandises endommag es lors de l ex p dition Les produits r par s ou remplac s seront soumis aux cond...

Страница 28: ...ent le si des pi ces sont manquantes ou endommag es 800 334 6871 www cooperlighting com Brevets 5 381 323 5 515 252 et d autres brevets d pos s 2004 Cooper Lighting La reproduction de ce document est...

Отзывы: