background image

3

used in accordance with the instructions, may cause harmful interference to radio 
communications. However, there is no guarantee that interference will not occur in a 
particular installation. If this equipment does cause harmful interference to radio or
television reception, which can be determined by turning the equipment off and on, the
user is encouraged to try to correct the interference by one or more of the following
measures:

• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the

receiver is connected.

• Consult the dealer or an experienced radio/TV technician for help.

• Fixture must be connected to a 120 Volt, 60 Hz power source. Any other connection

voids the warranty.

• This motion activated twin floodlight should be installed by persons with experience in

household wiring or by a qualified electrician. The electrical system, and the method
of electrically connecting this fixture to it, must be in accordance with the National
Electrical Code and local building codes.

• For proper operation and protection against damage, the motion sensor head control

switches must be facing the ground.

• Disassembly of your fixture will void the warranty.

SAVE THESE INSTRUCTIONS.

WhWhator best results

• Install your fixture 8-12 feet above ground. The motion sensor 

is less sensitive above 12 feet.

• Locate fixture so motion moves across detection zone (L).

• Locate fixture away from heat producing sources to prevent fa l s e

t ri g g e ri n g . Also be careful not to include objects such as heat pumps, air conditioners,
l a u n d ry ve n t s, white walls and water in the detection zone whenever possibl e.

• Locate fixture away from moving objects such as trees and street traffic.

• DO NOT install more than one motion activated floodlight on one wall switch.

Step 1: Turn off the power at the main fuse/breaker box.

Step 2: Install protective lamp covers onto lampholders by

lining up the nipples on the covers, over the 
lampholder slots. Lock into place by twisting 
covers counterclockwise (M).

Step 3: Line up the holes on the mounting bracket with the holes on

your junction box. Using either (2) #6 screws or (2) #8 screws
(depending on size of the holes in your junction box), attach
the mounting bracket to your junction box (N).

Step 4: Thread fixture wires through coverplate gasket.

Step 5: Connect fixture black wire to house black wire, fixture

white wire to house white wire, and copper colored ground
wire (coming from the fixture coverplate) to house ground
wire using wire nuts provided.

Step 6: Attach fixture to the mounting bracket using the center bolt

provided. Insert plastic color matched plug in center 
bolt hole for finished appearance.

Step 7: Apply silicone caulking around edges of coverplate and in 

any open holes to provide a watertight seal from rain and
moisture.

Step 8: Insert gaskets into lampholders and screw bulbs into

each lampholder (do not overtighten bulbs).

Step 9: Turn power on at main fuse/breaker box.

Mounting your fixture

For best results

L

Round        Rectangular (horizontal)     Octagonal

Your fixture mounts 

to the following standard

junction boxes:

N

(wall mount)

M

(eave mount)

MS249R_MS249RW 325-1486.qxd  6/20/06  4:02 PM  Page 3

Содержание CMS249R

Страница 1: ......

Страница 2: ...gaskets C Light covers D 2 8 screws E 2 6 screws F 3 Wire nuts G Mounting bracket H Center bolt I Color matched center hole plug J Indoor alarm module K WhWhat to know For outdoor use only fixture fo...

Страница 3: ...e away from heat producing sources to prevent false triggering Also be careful not to include objects such as heat pumps air conditioners laundry vents white walls and water in the detection zone when...

Страница 4: ...At dusk lights will operate in the AUTO or NIGHT TIME ON settings Refer to page 6 for detailed descriptions of the different modes The sensor and indoor alarm lamp module must be set to the same hous...

Страница 5: ...mp module module will sound a distinctive warning tone sequence A volume control HIGH MEDIUM LOW OFF is located on the side of the module to set the desired sound level If you desire the lamp to come...

Страница 6: ...the next dawn The light will operate in the first NIGHT TIMEON mode selected 2 hour or 4 hour even if changed Keep the power to the fixture on 4 Hour NIGHT TIME ON then Motion Activated Lights should...

Страница 7: ...ing in the detection zone is triggering the sensor If this is the case reduce the sensitivity Reposition motion sensor If the lights stay on with sensor lens covered contact customer service Is the un...

Страница 8: ...w to select your desired feature If lights do not come on at all in NIGHT TIME ONmode Is the surrounding external ambient light too bright If so the unit may think it s daytime Re aim the head Relocat...

Страница 9: ...implied warranty lasts so the above exclusions or limitations may not apply to you No other warranty written or verbal is authorized by the Company This warranty gives you specific legal rights and yo...

Страница 10: ...impermeable L se incluye Detector de movimiento y portal mparas A Junta obturadora de la placa de la cubierta B 2 Junta obturadora del recept culo C Cubiertas de las luces D 2 Tornillos No 8 E 2 Torni...

Страница 11: ...a empalmes de alimentaci n utilize un cableado de temperatura nominal de al menos 75 grados C Para funcionamiento correcto y protecci n contra da os los conmutadores de control del cabezal detector de...

Страница 12: ...es o m s alcance m ximo NOTA La temperatura puede afectar la sensibilidad del detector de movimiento Es posible que sea necesario reajustar la sensibilidad cuando se producen cambios grandes de tem pe...

Страница 13: ...ece encendida por 10 minutos Si se detecta movimiento por la noche la l mpara se encen der por 10 minutos Si el artefacto detecta movimiento ya sea de noche o de d a la alarma sonar OFF Apagado Apagad...

Страница 14: ...vimiento Si el sensor exterior esta en la posicion AUTO la l mpara no se encendera mas que en la noche en la posicion AUTO la l mpara exteri or se enciende siempre cuando la l mpara exterior se encien...

Страница 15: ...deben apagarse despu s de un intervalo de 8 minutos sin movimiento NIGHTTIMEON Encendido de noche 4 HR 4 Horas NOTA Una vez que la luz se enciendeen el modo de NIGHT TIME ON seleccionado no se puede...

Страница 16: ...sensor cubierta p ngase en contacto con el servicio de asistencia al cliente Est el farol en el Modo AUTO Aseg rese de que no est en uno de los dos Modos de NIGHTTIME ON LAS LUCES SE ENCIENDEN DURANTE...

Страница 17: ...unidad actuar como si fuera de d a Redirija el cabezal Cambie la ubicaci n de la unidad o dir jala en direcci n contraria a la luz LA ALARMA INTERIOR NO SUENA Est el volumen del m dulo interior ajusta...

Страница 18: ...RANTIA EXPRESA En algunos estados no se permite la exclusi n o limitaci n de da os incidentales o conse cuenciales o limitaciones sobre la duraci n de la garant a impl cita de manera que las exclusion...

Страница 19: ...ande manuelle Ce Tournevis phillips 2 Ampoules de projecteur PAR 38 de 150 watts maximum Produit de calfatage r sistant aux intemp ries Ce qui est co D tecteur de mouvement et pi ce fixe du projecteur...

Страница 20: ...alifi Le syst me lectrique de la maison et la m thode du branchement de cette pi ce fixe cette instal lation lectrique doivent respecter les sp cifications du Code lectrique national ainsi que les r g...

Страница 21: ...respondantes sont approximativement de L 9 m courte port e M 12 15 m port e moyenne H 18 m ou plus port e maximale REMARQUE La temp rature peut affecter la sensibilit du d tecteur de mouvement Il peut...

Страница 22: ...i vous n tes pas satisfait par la performance en utilisant un codage donn pour la maison passez le module sur une sortie diff rente N oubliez pas que le capteur et le module doivent tre tout moment su...

Страница 23: ...allumera que le soir en mode AUTO la lampe int rieure s allume lorsque l clairage ext rieur s allume La lampe int rieure demeurera allum e durant 10 minutes apr s que tout mou vement ait cess l ext ri...

Страница 24: ...e dispositif sous tension R glage du Soir au Matin Mode Prioritaire activ uniquement la nuit Les clairages doivent rester allum s du cr puscule l aurore puis se restaurer d s l aurore en mode de fonct...

Страница 25: ...ffecte le d tecteur de mouvement Viser les lampes nouveau Positionner nouveau le d tecteur de mouvement LES LUMI RES SONT ALLUMEES AU JOUR Est ce que l interrupteur qui se trouve au bas du d tecteur d...

Страница 26: ...l conque travail de r paration ou de remplacement puisse tre ex cut suivant les condi tions de la garantie Cette garantie ne couvre que les d faillances du produit dues des d fauts de mat riau ou de f...

Страница 27: ...n pour produits retourn s mis par la Soci t sera refus Cooper Lighting n est pas responsable des marchandises endommag es lors de l ex p dition Les produits r par s ou remplac s seront soumis aux cond...

Страница 28: ...ent le si des pi ces sont manquantes ou endommag es 800 334 6871 www cooperlighting com Brevets 5 381 323 5 515 252 et d autres brevets d pos s 2004 Cooper Lighting La reproduction de ce document est...

Отзывы: