Regency Ultimate™ U900E Gas Fireplace
| 5
safety decal
This is a copy of the label that accompanies each U900E-NG and U900E-LP Direct Vent Gas Fireplace. We have printed a copy of the contents here for
your review.
NOTE:
Regency
®
units are constantly being improved. Check the label on the unit and if there is a difference, the label on the unit is the correct one.
COPY OF SAFETY DECAL
For the State of Massachusetts, installation
and repair must be done by a plumber or
gasfitter licensed in the Commonwealth of
Massachusetts.
For the State of Massachusetts, flexible con
-
nectors shall not exceed 36 inches in length.
For the State of Massachusetts, the appli
-
ances individual manual shut-off must be a
t-handle type valve.
The State of Massachusetts requires the
installation of a carbon monoxide alarm in
accordance with NFPA 720 and a CO alarm
with battery back up in the same room where
the gas appliance is installed.
Part #:
919-624
Colour:
Black on grey except what is indicated as being printed red.
Size:
(File at 100%) 9.3"w x 5.9"h
Material:
2 ml silver matt polyester (DPM SMS)
Dec 14/15:
Created draft
Feb 24/16:
Updated
Mar. 10/16:
Updated Heatwave kit part #
DO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE
443
443
DOOR SEAL: Please
check that the door is
properly sealed
FPI Fireplace Products International Ltd. Delta, BC, Canada
Minimum Clearances to Combustibles /
Dégagement minimum des matériaux combustibles
Serial No./ No de Série
919-624
MAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE
.
Listed/Nom:
VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATION
Certified for/Certifi e pour:
CANADA and U.S.A.
é
Tested to:
CAN/CGA-2.17-M91(R2009)
ANSI Z21.88-2014
Conforms to:
CSA 2.33-2014
Certified to:
Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.
Fan Part # 910-157/P
Made in Canada/ Fabriqué au Canada
Duplicate S/N
(
See Instruction Manual for
detailed instructions)
(Voir Manuel pour plus de détails)
APPAREIL FONCTIONNANT AU GAZ PROPANE
CONÇU POUR FOYER : Modèle U900E-LP
PROPANE GAS: Model U900E-LP
NATURAL GAS: Model U900E-NG
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
APPAREIL FONCTIONNANT AU GAZ NATUREL
CONÇU POUR FOYER : Modèle U900E-NG
5.0" WC/C.E. (1.25 kPa)
3.5" WC/C.E. (0.87 kPa)
1.6" WC/C.E. (0.40 kPa)
# 35 DMS
34,000 Btu/h (9.96 kW)
23,500 Btu/h (6.89 kW)
0-4500 ft/pi (0-1372 m)
11“ WC
(2.73 kpa)
10" WC/C.E. (2.49 kPa)
6.4" WC/C.E. (1.60 kPa)
# 52 DMS
31,500 Btu/h (9.23kW)
25,000 Btu/h (7.33 kW)
0-4500 ft/pi (0-1372 m)
Minimum supply pressure
Manifold pressure - High
Manifold pressure - Low
Orifice size
Maximum input
Minimum input
Altitude
D
E
F
A
B
C
Side Walls / Murs latéraux
A
8” (203 mm)
Ceiling / Plafond
B 48” (1219 mm)
Min. Mantel Height
/Hteur Min
Manteau
C
20" (508 mm)
Max. Mantel Depth/Profondeur
Max Manteau
D
12” (305 mm)
Alcove Width/Largeur Alcôve
E
84" (1524 mm)
Alcove Depth/Profondeur Alcôve
F
36" (2134 mm)
This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.
This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the
United States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard or ANSI A119.2 ou NFPA 501C Standard for Recreational Vehicles
This appliance is only for use with the type(s) of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by
local codes. See owner's manual for details. This appliance is supplied with a conversion kit.
L'appareil doit être installé conformément aux codes et règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation National Fuel Gas Code ANSI Z223.1, ou CSA-B149.1 Natural Gas and
Propane Installation Code en vigueur.
L'appareil doit être installé conformément à la norme CAN/CSA-Z240, Série MM, Maisons mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction
and Safety Standard. Si ces normes ne sont pas applicables, veuillez vous référer à la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard, ou ANSI A119.2 ou NFPA 501C
Standard for Recreational Vehicles.
Cet appareil doit être utilisé uniquement avec les types de gaz indiqués sur la plaque signalétique et peut être installé dans une maison préfabriquée (É.-U. seulement) ou mobile installée à demeure si les règlements
locaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Une trousse de conversion est fournie avec cet appareil.
f si une trousse de conversion certifiée est fournie.
4001172
For Use Only with Barrier (Part # 466-111) Follow installation instructions. Utiliser uniquement avec l’écran (n °466-111). Suivre les instructions d'installation.
Pression d'allimentation minimum
Pression de sortie (manifold) - Haute
Pression de sortie (manifold) -
Basse
Taille de l’orifice
D bit Calorifique maximum
é
D bit Calorifique minimum
é
Altitude
Pression d'allimentation minimum
Pression de sortie (manifold) - Haute
Pression de sortie (manifold) - Basse
Taille de l’orifice
D bit Calorifique maximum
é
D bit Calorifique minimum
é
Altitude
VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.
NE PAS UTILISER AVEC UN COMBUSTIBLE SOLIDE.
FOYER AU GAZ À ÉVACUATION -
Part No. 946-753 register kit may be used. La trousse de registre (no.de pièce 946-753 ) peut être utilisée
.