FPI FIREPLACE PRODUCTS INTERNATIONAL LTD.  6988 Venture St., Delta, BC  Canada, V4G 1H4

919-625c

12.14.16

Tested by:

Installer

: Please complete the details on the back cover 

and leave this manual with the homeowner.

Homeowner:

 Please keep these instructions for future reference.

www.regency-fire.com

 

-  Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other 

appliance. 

- WHAT TO DO IF YOU SMELL GAS
 • 

Do not try to light any appliance.

 

•  Do not touch any electrical switch: do not use any phone in your building.

 

  Leave the building immediately.

 

•  Immediately call your gas supplier from a neighbour's phone. Follow the gas supplier's  

instructions.

 

• If you cannot reach you gas supplier, call the fire department.

 

 

 

- Installation and service must be performed by a qualified installer, service agency or the gas supplier.

     WARNING
FIRE OR EXPLOSION HAZARD

Failure to follow safety warnings exactly could result in serious
injury, death, or property damage. 

Regency Ultimate

 U900E

Gas Fireplace

Owners & 

Installation Manual

MODELS:    U9

00E-NG Natural Gas

                    U9

00E-LP  Propane

Содержание U900E

Страница 1: ...ot try to light any appliance Do not touch any electrical switch do not use any phone in your building Leave the building immediately Immediately call your gas supplier from a neighbour s phone Follow the gas supplier s instructions If you cannot reach you gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier WA...

Страница 2: ...mobile home where not prohibited by local codes This Direct Vent System Appliance must be installed in accordance with the manufacturer s installation instructions and the Manufactured Home Construction and Safety Standard Title 24 CFR Part 3280 or the current Standard of Fire Safety Criteria for Manufactured Home Installations Sites and Communities ANSI NFPA 501A and with CAN CSA Z240 MH Mobile H...

Страница 3: ...warmth and charm of a fireplace at the flick of a switch The model U900E has been approved by Warnock Hersey Intertek for both safety and efficiency As it also bears our own mark it promises to provide you with economy comfort and security for many trouble free years to follow Please take a moment now to acquaint yourself with these instructions and the many features of your Regency Fireplace ...

Страница 4: ...nry chimney 30 Venting Arrangements Vertical Termination 31 Unit Installation with Horizontal Termination 32 4 x 6 5 8 venting 32 Unit Installation with Horizontal Termination 33 Dura Vent Horizontal terminations 34 Unit installation with Vertical Termination 35 4 x 6 5 8 venting 35 Vertical Termination 4 x 6 7 8 Venting 36 Flex vent components 37 High Elevation 38 Gas Line Installation 38 Pilot A...

Страница 5: ...eur Min Manteau C 20 508 mm Max Mantel Depth Profondeur Max Manteau D 12 305 mm Alcove Width Largeur Alcôve E 84 1524 mm Alcove Depth Profondeur Alcôve F 36 2134 mm This appliance must be installed in accordance with local codes if any if none follow the National Fuel Gas Code ANSI Z223 1 or Natural Gas and Propane Installation Code CSA B149 1 This appliance must be installed in accordance with th...

Страница 6: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than one half 1 2 inch in size GAS VENT DIRECTLY BELOW KEEP CLEAR OF ALL OBSTRUCTIONS 4 INSPECTION The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless upon inspecti...

Страница 7: ...Regency Ultimate U900E Gas Fireplace 7 dimensions ...

Страница 8: ... we are required by the Canadian Safety Standards and ANSI Standards to make you aware of the following CLOTHING OR OTHER FLAMMABLE MATERIAL SHOULD NOT BE PLACED ON OR NEAR THE APPLIANCE CHILDREN AND ADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATURES ESPE CIALLY THE FIREPLACE GLASS AND SHOULD STAY AWAYTO AVOID BURNS OR CLOTHING IGNITION GENERAL SAFETY INFORMATION 1 The appliance ...

Страница 9: ...s f Heatwave kit 13 Reinstall installation access panel 14 Final check Before leaving this unit with the customer the installer must ensure that the appliance is firing correctly and operation fully explained to customer LOCATING YOUR GAS FIREPLACE 1 When selecting a location for your fireplace ensure that the clearances are met 2 The appliance must be installed on a flat solid continuous surface ...

Страница 10: ...ance that this fireplace and vent system be installed only in accordance with these instructions Clearance Dimension Measured From A Mantel Height min 20 508mm Top of Fireplace Opening B Sidewall on one side 8 203mm Side of Fireplace Opening C Ceiling room and or alcove 48 1219mm Top of Fireplace Opening D Mantel Depth max 12 305mm 29 Above Fireplace Opening E Alcove Width 84 2134mm Sidewall to Si...

Страница 11: ...its themantelclearances are critical Combustible mantel clearances from top of front facing are shown in the diagram on the right Note Ensure the paint that is used on the mantel and the facing is high quality or the paint may discolour MANTEL LEG CLEARANCES Combustible mantel leg clearances as per diagram ...

Страница 12: ... set as far forward on the firebox as possible The nailing strips can be adjusted back up to 1 1 2 38mm to allow for varying thicknesses in non combustible material wall finishes INSTALLATION ACCESS PANEL The unit is equipped with a removable access panel for pre finish installation of optional components this panel is located on the lower front face 1 Remove 4 screws to remove access panel 2 Easi...

Страница 13: ...facing height 20 508mm I Gas Connection Opening Height 1 11 16 43mm J Gas Connection Height 2 11 16 67mm K Gas Connection Inset 1 1 8 29mm L Gas Connection Opening Width 4 11 16 119mm Framing depth measurement is noted with the nailing strips set as far forward on the firebox as possible The nailing strips can be adjusted back up to 1 1 2 38mm to allow for varying thicknesses in non combustible ma...

Страница 14: ...trip adjust and retighten screws 4 Attach both vertical studs 466 126 to the vertical wood studs and secure using 6 screws 2 at bottom 2 at top and 2 on sides as shown NOTE Ensure the flat side of the steel stud is facing the wood framing 466 126 Flat side out 5 Secure horizontal steel header stud 466 128 with 2 screws per side as per diagram 6 Slide the unit into position Hook up gas venting elec...

Страница 15: ...Install the vertical section of the deflector to the top of the firebox with 3 screws as shown below 3 Install the horizontal section of the deflector to the vertical section at the desired height with 2 screws 4 If the deflector extender is required install with 2 screws extend to desired length before tightening screws 5 If there is any excess material on the horizontal section of the deflector ...

Страница 16: ...n the Low Voltage Junction box 5 Install batteries only if 120 volt power will not be used Batteries are only used if power is lost within the home and serve as a secondary power source Insert the 4 AA type batteries in the battery compartment with the correct polarity 6 Place the slider into the cover plate 7 Put the Battery Holder switch in the OFF position to allow correct lineup for slider swi...

Страница 17: ...5 Mud seams as normal We recommend using a product called Durabond high strength compound for the first coat This product can be found at any hardware store Mud must be cured as per manufacturer s recommendations 6 Prime wall for a second time for proper adhesion of paint 7 Paint walls using a high quality paint which will withstand the high temperatures being emitted from this appliance NON COMBU...

Страница 18: ...terials See Clearances section Combustible materials can be laid against the side and back standoffs and the stove base 4 Non combustible material ie tile slate etc may be brought up to and overlap the unit top and bottom ensuring that the maximum thickness does not go beyond the 1 1 2 as shown in the diagram below The faceplate will not be able to be mounted if finished material is beyond 1 1 2 1...

Страница 19: ...egency Horizon Fireplace is as critical as the installation itself The temperatures around linear gas fireplaces are typically higher than would be acceptable for combustible materials Your Regency Horizon Fireplace is no exception to this rule Therefore the units are specified with non combustible required materials to specific dimensions above and around the units This is due to these areas reac...

Страница 20: ...nded above meter regulator assembly 36 90cm a J Clearance to service regulator vent outlet 36 90cm K Clearance to non mechanical air supply inlet to building or the combustion air inlet to any other appliance 12 30cm 9 23cm L Clearance to a mechanical air supply inlet 3 91cm above if within 10 3m horizontally 72 1 8m 36 90cm b M Clearance above paved sidewalk or a paved driveway located on public ...

Страница 21: ...he inside top of the firebox To set the vent restriction as indicated in the venting arrangements diagrams refer to the following instructions 1 Remove the glass door and inner panels see instructions in this manual 2 Remove6screws 3front 3back toremoveheatbaffletoaccessrestrictor plate Heat Baffle 3 Remove the screws that hold the vent restrictor in place 4 Adjust the vent restrictor plate to the...

Страница 22: ...n of 4 feet 1 6 7 8 dia flexible liner 4 ft length 2 4 dia flexible liner 4 ft length 3 spring spacers 4 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube of Mill Pac 1 8 plated screws 8 9 screws 8 x 1 1 2 Drill Point Stainless Steel 4 1 6 7 8 dia flexible liner 10 ft length 2 4 dia flexible liner 10 ft length 3 spring spacers 7 4 thimble 2 5 AstroCap termination cap 1 6 screws 12 7 tube...

Страница 23: ...e Length 7 Black N A N A 4D7AB N A N A N A Extension Pipe 8 1 2 Galvanized 46DVA 08A N A N A N A N A N A Extension Pipe 8 1 2 Black 46DVA 08AB N A N A N A N A N A Adjustable Length 12 Galvanized N A N A 4D12A N A SV4LA12 TC 4dLSI Adjustable Length 12 Black N A N A 4D12A N A SV4LBA12 TC 4dLSIB Extension Pipe 16 Galvanized 46DVA 16A N A N A N A N A N A Extension Pipe 16 Black 46DVA 16AB N A N A N A ...

Страница 24: ...T36 Basic Horizontal Termination Kit A Disc 4DT HKA 4DHTK2 4DHTKA SV SHK TM4 HTK Horizontal Termination Kit B 46DVA KHA Changed Components 4DT HKB 4DHTK1 4DHTKB SV HK TM4 HTK Vertical Termination Kit Disc 4DT VKC 4DHTK 4DHTK SV FK N A FPI 946 506 P Vent Guard Optional for AstroCap 946 205 Vinyl Siding Shield for Riser Vent Terminal 510 994 Rigid Pipe Adaptor Must use with all rigid piping 946 208 ...

Страница 25: ...Installation Wall Thickness inches Vent Length Required inches 3 1 4 6 3 4 11 14 5 8 Adj Pipe 7 3 4 16 1 4 17 24 Adj Pipe 7 1 4 8 3 4 6 12 9 9 4 1 4 5 3 4 6 9 WARNING Do not combine venting components from different venting systems However use of the AstroCapTM and Regency Riser is acceptable with all systems This product has been evaluated by Intertek for using a Rigid Pipe Adaptor in conjunction...

Страница 26: ...NATIONS The diagram shows all allowable combinations of vertical runs with horizontal terminations using one 90o two 45o elbows equal one 90o elbow Note Must use optional rigid pipe adapter Part 510 994 when using Rigid Pipe Venting Systems Maintain clearances to combustibles as listed in Clearances section Horizontal vent must be supported every 3 feet Firestops are required at each floor level a...

Страница 27: ...enting Systems Two 45o elbows equal to one 90o elbow Vent must be supported at offsets Minimum distance between elbows is 1 ft 305mm Maintain clearances to combustibles as listed in the Clearances section Horizontal vent must be supported every 3 feet Firestopsarerequiredateachfloorlevelandwhenever passing through a wall Must use optional rigid pipe adaptor Part 510 994 when using rigid pipe vent ...

Страница 28: ...options max totalpipelength is 30 feet with min of 10 feet total vertical and max 8 feet total horizontal Please note min 1 foot between 90o elbows is required A 0 Min 2 Max 2 Min B 1 Min 2 Max 3 Min C 2 Min 3 Max 4 Min D 3 Min 4 Max 6 Min E 4 Min 5 Max 7 Min F 5 Min 6 Max 8 Min G 6 Min 7 Max 9 Min H 7 Min 8 Max 10 Min Restrictor Set 0 3 Factory Setting ...

Страница 29: ...0o elbows is required A 1 Min 3 Max B 2 Min 4 Max C 3 Min 5 Max D 4 Min 6 Max E 5 Min 7 Max F 6 Min 8 Max Restrictor Set 0 3 Factory Setting Option V H V V1 H H1 With these options max total pipe lengthis30feetwith min of 12 feet total vertical and max 9 feet total horizontal Please note min 1 foot between 90o elbows is required A 0 Min 1 Max 1 Min 2 Max B 1 Min 2 Max 3 Min 3 Max C 2 Min 2 Max 5 M...

Страница 30: ... section for minimum and maximum heights NOTE Maximum flue height is 30 feet Masonry chimneys may take various contours which the flexible liner will accommodate However keep the flexible liner as straight as possible avoid unnecessary bending The Air Intake pipe must be attached to the inlet air collar of the termination cap Required Parts Part Description 946 529 Co linear DV Vertical Terminatio...

Страница 31: ...on The shaded area in the diagrams show the allowable vertical terminations Restrictor Position Set 0 3 Factory Setting VENTING ARRANGEMENTS VERTICAL TERMINATION with Co linear Flex System for both Residential Manufactured Homes into Masonry Fireplaces ...

Страница 32: ... collar Fasten to the outer collar only with the 3 supplied screws drilling pilot holes will make this easier 4 Level the fireplace and fasten it to the framing using nails or screws through the side nailing strips Diagram 1 Note For best results and optimum performance with each approved venting system it is highly recommended to apply Mill Pac sealant supplied to every inner pipe connection Fail...

Страница 33: ...re markings on the cap indicating which way is up This will position the termination cap with proper down slope for draining water Fasten the cap to the outer wall with the 4 supplied screws 6 Pull the centre inner and outer flex liner out enough to slip over the flue collars of the fireplace You may wish to cut the liner shorter to make it more workable Do not bend liner more than 90o The liners ...

Страница 34: ...ctions completely together then twist lock one section clockwise approximately one quarter turn until the two sections are fully locked Thefemale locking lugs will not be visible from the outside on the Black Pipe or fittings They may be located by examining the inside of the female ends Diagram 1 b Horizontal runs of vent must be supported everythreefeet Wallstrapsareavailable for this purpose 5 ...

Страница 35: ...on nections are in the fully twist locked position and sealed 5 Cut a hole in the roof centered on the small drilled hole placed in the roof in Step 2 The hole shouldbeofsufficientsizetomeettheminimum requirementsforclearancetocombustibles Slip theflashingundertheshingles shinglesshould overlap half the flashing as per Diagram 3 6 Continue to assemble pipe lengths Note If an offset is necessary in...

Страница 36: ...G VERTICAL FLEX VENT KIT 946 755 11 Secure inner flex pipe to pipe adaptor by using Mill Pac over the adaptor Slide the inner pipe over adaptor and secure with 3 screws 12 Repeat Step 11 to secure outer flex Diagram 4 14 Put a bead of caulking on the exterior between the outer pipe and flashing to prevent water from penetrating the chimney system 15 Slide storm collar over pipe length until it rea...

Страница 37: ...0ft 10 spring spacers 1 919 698 919 698 08 10 16 08 10 16 60 1 4 Ceiling firestop 60 1 4 Ceiling firestop Diagram 1 Diagram 1 Diagram 1a Diagram 1a Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Enclosure Ceiling firestop Flashing Termination Cap Storm Collar Roof support Ceiling firestop Firestop spacer to prevent debris from falling into the ceiling ...

Страница 38: ...r the current National Fuel Gas Code ANSI Z223 1 When using copper or flex connectors use only approved fittings Always provide a union so that gas lines can be easily disconnected for servicing Flare nuts for copper lines and flex connectors are usually considered to meet this requirement NOTE A shutoff dante valve should be sup plied in or near the unit or as per local codes for ease of servicin...

Страница 39: ...og tray by removing 3 screws as shown in Diagram 2 below Diagram 2 Side Panel Front Lip Log Tray Screw Locations Side Panel Screws Log Tray Screws Front Lip Screws Diagram 3 Burner Screw Locations 7 Remove burner by removing 2 screws in locations shown below 8 You can now access the air shutter and adjust aeration AERATION ADJUSTMENT The burner aeration is factory set but may need adjusting due to...

Страница 40: ...ply is needed for the fan blower operation CAUTION Ensure that the wires do not touch a hot surface and are away from sharp edges WARNING Electrical Grounding Instructions This appliance is equipped with a three pronged grounding plug for your protection against shock hazard and should be plugged directly into a properly grounded three prong receptacle Do not cut or remove the grounding prong from...

Страница 41: ...d under warranty Log kit 466 930 contains the following pieces 1 Line up locators on Log 1 with corresponding locators on Log Tray as shown in Diagram 2 2 Line up locators on Log 2 with corresponding locators on Ceramic Log Burner as shown in Diagram 3 3 Line up locator on Log 3 with corresponding locator on Ceramic Log Burner as shown in Diagrams 4 and 5 Diagram 2 Diagram 3 Diagram 4 Diagram 5 3 ...

Страница 42: ... and Log 3 as shown in Diagram 9 8 Line up locator on bottom of Log 7 with locator on Ceramic Log Burner as shown in Diagram 10 6 Log 5 final position shown in Diagram 8 6 Log 8 in final position shown in Diagram 11 Place supplied embers over burner screw holes in locations shown below Diagram 7 Diagram 8 Diagram 9 Diagram 10 Diagram 11 Log 8 and ember locations Diagram 6 3 6 1 3 8 7 4 4 1 1 2 2 2...

Страница 43: ... below to remove front trim piece 3 Reverse steps to reinstall 1 Remove front trim piece see instructions above 2 Remove two 2 screws in locations shown below to release panel clips 3 Remove panels by sliding out 4 Reverse steps to reinstall Front Trim Piece Panel Clip Screw Locations Panel Clip Diagram 1 Front Trim Screw Locations INNER PANEL REMOVAL INSTALLATION FRONT TRIM REMOVAL INSTALLATION ...

Страница 44: ...ending in 6 tabs in locations shown below 4 Hook the inner door frame 3 and safety screen assembly 2 over the inner door trim 1 5 Bend the center tab up and secure with a screw to attach the inner door frame safety screen assembly to the inner door trim 7 Attach completed assembly to the glass door on unit 8 Secure the assembly with 1 screw on each side Note Bottom of frame is secured to glass doo...

Страница 45: ... protrudes slightly beyond the faceplate Warning Turn off the unit by way of the wall switch or remote Allow unit to cool at least 10 min prior to removing the faceplate Diagram 1 Glass Surround Install Diagram 3 Final Install Diagram 2 adjustments 1 4 6mm 1 2 13mm Use first notch in bracket for standard installation GF900 GF1500L 919 615 11 05 15 1 OPTIONAL FINISHING TRIM INSTALLATION tooltip too...

Страница 46: ...hooking the left and right side mounting brackets into the mounting slots at the side of the firebox as shown below It is recommended that you use the first mounting slot the one closest to the door frame overlay out of the 3 so that the faceplate and door frame overlay are flush with one another See diagram below NOTE There are 3 mounting slots available this is to accommodate any finishing that ...

Страница 47: ...irst few fires a white film may develop on the glass front as part of the curing process The glass should be cleaned or the film will bake on and become very difficult to remove Use a non abrasive cleaner and NEVER clean the glass while it is hot DO NOT BURN THE APPLIANCE WITHOUT THE GLASS FRONT IN PLACE 8 Remote control requires coding See remote coding instructions for details NOTE This applianc...

Страница 48: ...start second try for ignition by sparking for approximately 60 seconds If there is still no positive ignition the board will go into lock out The system will need to be reset as follows a Turn the system off by pressing the ON OFF button on the remote b Wait 5 minutes then repeat from step 2 SHUTDOWN PROCEDURE 1 Press the ON OFF button on the remote 2 If service is to be performed you must disconn...

Страница 49: ...r un incendie ou une explosion pouvant entraîner des dégâts matériels ou des blessures pouvant être mortelles Tout défaut d installation d ajustement de modification de service ou d entretien peut entraîner des blessures ou des dommages matériels Reportez vous au manuel d utilisation fournie avec cet équipement Pour obtenir de l aide ou des informations complémentaires consulter un installateur qu...

Страница 50: ...oughout the cycling process WARNING CHILDRENANDADULTS SHOULD BE ALERTED TO THE HAZARDS OF HIGH SURFACE TEMPERATUREANDSHOULDSTAY AWAYTOAVOIDBURNSORCLOTH ING IGNITION YOUNG CHILDREN SHOULD BE CAREFULLYSUPER VISED WHEN THEY ARE IN THE SAME ROOMAS THEAPPLIANCE 8 Each time the appliance is lit it may cause condensation and fog the glass This conden sation and fog is normal and will disappear in a few m...

Страница 51: ...In the event that you break your glass by impact purchase your replacement from an authorized Regency dealer only Replacement neo ceramic glass Part 940 373 P is shipped with gasket GENERAL VENT MAINTENANCE Conduct an inspection of the venting system semi annually Recommendedareastoinspectasfollows 1 ChecktheVentingSystemforcorrosioninareas that are exposed to the elements These will appear as rus...

Страница 52: ...Reverse steps to reinstall fan 8 Remove access panel by removing eight 8 screws in locations shown in Diagram 4 Diagram 5 Fan Screws Diagram 4 Access Tray screws Diagram 1 Burner Side Panels 4 Remove enamel side panels by loosening the 2 screws 1 per side in locations noted and remove the 2 clips 5 Remove front lip by removing 2 screws located on firebox floor 6 Remove rear log tray by removing 3 ...

Страница 53: ...he other lower door latch 6 Pull the bottom of the door towards you until the door is angled away from the firebox by about 30 Lift the door up and over the upper door hooks 7 To install the glass door reverse steps 1 Insert the door tool into the lower door latch WARNING Do not operate the appliance with the glass panels removed cracked or broken Replacement of the glass panels should be done by ...

Страница 54: ...glass door front trim piece and inner panels see instructions in this manual 2 Remove logs 3 Remove burner side panels by lifting out as shown in Diagram 1 Diagram 1 Burner Side Panels 4 Remove enamel side panels by loosening the 2 screws 1 per side in locations noted and remove the 2 clips 5 Remove front lip by removing 2 screws located on firebox floor 6 Remove rear log tray by removing 3 screws...

Страница 55: ... Mount White GTM SIT 0 584 803 910 428 Receptacle Duplex White 910 430 Receptacle Cover Duplex Metal 396 042 F Glass Door Frame Tool 910 100 Pilot Orifice NG 910 101 Pilot Orifice LP 911 010 Stepper Motor NG 911 011 Stepper Motor LP 910 432 Pilot Tube Includes Fittings 911 037 Flame Sense 911 038 Flame Electrode 911 039 Two Way Pilot Hood Part Description 17 396 527 Bottom Door Latch 18 636 576 P ...

Страница 56: ...56 Regency Ultimate U900E Gas Fireplace parts list MAIN ASSEMBLY ...

Страница 57: ...2 33 Part Description 32 636 914 Inner door frame Black w Screen 33 636 924 Faceplate Door Frame Black 636 951 Faceplate Door Frame Black Glass not shown 467 900 Steel Stud Framing not shown 636 936 Non combustible board not shown 636 969 LP conversion kit not shown ...

Страница 58: ...ttery Pack Remote Control Systems 2 Enamel Panels 1 Venting Venting Components 1 All Stainless steel surrounds 1 All Firebox Media Crystals Firebeads Volcanic Ceramic Spa Stones 1 All hardware 1 Mesh Glass Safety Barriers 1 Accent Light Bulbs 1 Glass Crazing 1 Conditions Warranty protects against defect in manufacture or FPI factory assembled components only unless herein specified otherwise Any p...

Страница 59: ...wndrafts installation error installation by an unqualified installer incorrect chimney components including but not limited to cap size or type operator error abuse misuse use of improper fuels lack of regular maintenance and upkeep acts of God weather related problems from hurricanes tornados earthquakes floods lightning strikes bolts or acts of terrorism or war which result in malfunction of the...

Страница 60: ...al codes for additional terms which may be applicable to this warranty How to Obtain Warranty Service Customers should contact the authorized selling dealer to obtain warranty service In the event the authorized selling dealer is unable to provide warranty service please contact FPI by mail at the address listed below Please include a brief description of the problem and your address email and tel...

Страница 61: ...in order for us to serve you better Warranty Registration Form or Register online immediately at the above Web Site Warranty Details Serial Number required Purchase Date required mm dd yyyy Product Details Product Model required Dealer Details Dealer Name required Dealer Address Dealer Phone Installer Date Installed mm dd yyyy Your Contact Details required Name Address Phone Email For purchases ma...

Страница 62: ......

Страница 63: ......

Страница 64: ...mation Dealer Name Address _______________________________________________ ___________________________________________________________________ Installer ____________________________________________________________ Phone ____________________________________________________________ Date Installed _______________________________________________________ Serial No ______________________________________...