CONVERSION KIT# 434-972 FROM NG TO LP
For P33SE using SIT 886 NOVA Gas Valve
THIS CONVERSION MUST BE DONE BY A QUALIFIED GAS FITTER IF IN DOUBT DO NOT DO THIS CONVERSION !!
9)
Remove regulator and discard. Install Hi/
Lo pressure regulator onto the valve with
2 screws as shown below.
10)
Attach the label “This unit has been
converted to LPG” near or on top of the
serial # decal.
11)
Replace yellow “NG” label with red
“LPG” label.
12)
Reverse steps 2 - 1.
13)
Check for gas leaks.
14)
Check inlet and outlet pressures.
15)
Check operation of fl ame control.
Installer Notice:
These instructions must be left
with the appliance.
Each Kit contains one LPG
Conversion Kit # 434-972
LPG Conversion Kit Contains:
Qty. Part #
Description
1
904-241
Burner Orifi ce #56
1
918-590
Decal "Converted to
LPG"
1
908-528
Red "LPG" label
1 904-529
5/32"
Allen
Key
1 910-101
LPG
Injector
(Pilot
Orifi
ce)
1
911-009
Hi/Lo Conversion LP
1 918-862
Instruction
Sheet
Installation of the LPG
Conversion Kit:
1)
Shut off the gas supply.
2)
a) Remove the Faceplate by lifting it off
of the fl ush door.
b) Remove the fl ush door.
c) Remove the Glass Crystals or
Ceramic Stones. Also remove
Stainless Steel Panels - if installed.
d) Remove the 2 screws holding the
Burner Assembly to the fi rebox base.
Lift out the burner assembly.
6)
Unscrew the pilot orifi ce with the Allen
key and replace with the LPG pilot orifi ce
in the kit and replace pilot cap.
7)
Remove burner orifi ce with a 1/2"
wrench and discard. Use another
wrench to hold on to the elbow below
the orifi ce.
Burner Orifi ce
8)
Reinstall new burner orifi ce LPG
stamped #56 and tighten.
3)
With Burner Assembly removed, lift out
fi rebox base.
4)
Remove the pilot cover to expose the pilot
cap.
5)
Pull off the pilot cap to expose the pilot
orifi ce.
Firebox base