Regency P33SE Gas Fireplace
13
INSTALLATION
G
H
I
I
M
J
L
K
P Q
O
N
10" (254mm)
dia. Hole through
wall Vent.
Opening for gas
connection
Top Header
.
Wood, drywall
or other facing
J
I
Floor
Framing Dimensions
Description
P33SE
G
Framing Width
33-1/4"(845mm)
H
Framing Height *
31-3/4" (806mm)
I
Framing Rise from Floor
1" (25mm) Min.
J
Framing Depth Vertical
Horizontal
19-1/2" (495mm)
Vertical Rise
16-1/2" (419mm)
Rigid
/ 12-3/4" (324mm)
Flex
K
Corner Wall Length
37-1/2" (953mm)
L
Corner Facing Wall Width
53-1/4" (1353mm)
M
Framed Chase Ceiling*
36" (914mm)
Rigid
32" (812mm)
Flex
N
Vent Centerline Height*
30" (762mm)
Rigid
26" (660mm)
Flex
O
Gas Connection Height*
1 1/2" (38mm)
P
Gas Connection Inset*
4" (102mm)
Q
Gas Connection Width*
3" (76mm)
FRAMING DIMENSIONS
NOTE:
If this is an outside corner, the
minimum distance between the vent
and the outside corner is 6" (15cm)
with AstroCap termination cap or 12"
(30cm) with Rigid Vent termination cap.
(For example Dura-Vent)
* Measured from base of unit.