PG36-5 Gas Log Fireplace
15
INSTALLATION
FLUEING ARRANGEMENTS - VERTICAL TERMINATIONS
SIMPSON DURA-VENT CO AXIAL FLUE GS SYSTEM
(LPG & NG)
The PG36 is approved for a 23 ft. (7.0m) vertical, with a maximum 12 ft. (3.7m) horizontal offset using
two 90
o
elbows (two 45
o
elbows equal one 90
o
elbow) with
Simpson Dura-Vent Co Axial Flue GS
fl ue
systems for LPG and NG, as per diagram 1.
The PG36 is approved for a 37 ft. (11.3m) straight vertical, including a 20" (0.5m) horizontal offset
using two 90
o
elbow (two 45
o
elbows equal one 90
o
elbow) with
Simpson Dura-Vent Co Axial Flue
GS
fl ue systems for LPG and NG, as per the diagram 2.
• Flue must be supported at offsets
• Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas
Fireplace," "Combustible Mantels," "Mantel Leg Clearances" & "Framing and Finishing"
sections.
Note: Must use optional fl ue adapter when using Simpson Dura-Vent pipe
(Part # 510-994).
Note: Regency
®
Co Axial Flue System (Flex) is only approved for horizontal terminations.
Diagram 1
Diagram 2