Regency
®
PG36-5 Gas Log Fireplace
13
INSTALLATION
18
20
24
22
2
0
12
6
16
26
28
30
32
34
36
38
4
14
8
10
2
0
4
5
2
0
3.5
1
5.5
4
4.5
1.5
0.5
3
2.5
2
0
3.5
1
1.5
0.5
3
2.5
1029mm
Minimum
Height
Requirement
M eters
Me
ter
s
FLUEING ARRANGEMENTS - HORIZONTAL TERMINATIONS
SIMPSON DURA-VENT DIRECT FLUE GS SYSTEM and
REGENCY
®
DIRECT FLUE SYSTEM (FLEX)
(LPG & NG)
The diagram shows all allowable combinations of vertical runs with horizontal terminations, using one 90
o
elbow (two 45
o
elbows equal
one 90
o
elbow).
Note: Must use optional fl ue adapter (Part # 510-994) when using Simpson Dura-Vent pipe.
Simpson Dura-Vent
4" (102mm) inner diameter
6-5/8" (168mm) outer diameter
Regency
®
Flex Vent
4" (102mm) inner diameter
6-7/8" (175mm) outer diameter
• Maintain clearances to combustibles as listed in the "Clearances," "Locating Your Gas Fireplace," "Combustible Mantels,"
"Mantel Leg Clearances" & "Framing and Finishing" sections.
• Horizontal fl ue must be supported every 3 feet (0.9 meters).
• Firestops are required at each fl oor level and whenever passing through a wall.
A fl ue guard should be used whenever
the termination is lower than the
specifi ed minimum or as per local
codes.
Note: Regency
®
Co Axial Flue System
(Flex) is only approved for
horizontal terminations.